• Title/Summary/Keyword: TC Coupled

Search Result 69, Processing Time 0.024 seconds

An Analysis and Reduction Design of Combustion Instability Generated in Hybrid Rocket Motor (하이브리드 로켓 모터의 연소불안정 분석 및 저감 설계)

  • Lee, Jungpyo;Rhee, Sunjae;Kim, Jinkon;Moon, Heejang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.4
    • /
    • pp.18-25
    • /
    • 2014
  • In this paper, the mechanism of the combustion instability which may occur in a hybrid rocket motor with a diaphragm was studied. And the new design for a hybrid motor grain was suggested. It could increase a regression rate of solid fuel, and reduce a large pressure oscillation in a hybrid rocket motor with a diaphragm. It was confirmed that the main mechanism of a large pressure oscillation was hole-tone, and it was caused by a collision between a diaphragm and a vortex which was generated in a pre-chamber. And 'Stepped Grain' design which had the mechanism for high regression rate in a motor with a diaphragm and could reduce a combustion instability was suggested.

Design of the Modified Wilkinson Power Divider Using Coupling and Inductive Slit (결합 특성과 유도성 슬릿을 이용한 새로운 구조의 Wilkinson 전력분배기 설계)

  • Kim, Jin-Pyo;Kim, Sang-Tae;Kim, Won-Gi;Na, Geuk-Hwan;Sin, Cheol-Jae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.8
    • /
    • pp.24-32
    • /
    • 2000
  • In this paper, we have designed and fabricated a new type power divider to be efficient to a size and electrical performance by folding each quarter-wavelength 70.7 Ω section into a tightly-coupled "meander-line" and inserting a slit. In this type, because of coupling, the electrical phase of quarter -wavelength line and the performance change. For this reason, with the inductive slit and the tuning of quarter-wavelength line length, we have compensated for those. The inductance value of the inserted slit is decided by its width and depth, therefore, we could improve the electrical performance through optimization of inductance. Input and output return losses of the designed power divider were -34.2 dB, -34.3 dB respectively, and isolation was -36.7 dB at 1.75 GHz. Besides, a new design approach reduced occupied substrate area by 3:1 approximately.

  • PDF

Ring Resonator Based Band-pass Filter with Enhanced Sideband Suppression (사사이드밴드 억압비가 향상된 링 공진기형 대역통과 필터)

  • Kyoung, Un-Hwan;Kim, Gun-Duk;Lee, Sang-Shin;Eo, Yun-Seong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.8-12
    • /
    • 2008
  • A ring resonator based band-pass filter enabling enhanced sideband suppression was proposed and demonstrated. It is composed of a single-ring based band-pass section combined with a band-rejection section based on two different coupled rings. The sideband region of the transfer characteristics of the first band-pass filter section was selectively suppressed by means of the band-rejection section without causing any excessive insertion loss. As a result, the overall transfer characteristics of the proposed filter was unproved so that its sideband suppression was elevated to allow for sharper roll-off and narrower bandwidth. In this work, a conventional single-ring band-pass filter and a proposed filter including the band-rejection section were designed and fabricated. As for the achieved device performance, with the center frequency at about 4 GHz, the sideband suppression ratio was increased as much as 8 dB and the 3-dB bandwidth was reduced from 98 MHz to 48 MHz by about 51% with no remarkable excessive insertion loss as expected. And the quality factor of the device was increased by about 105%.

Antibody radiolabeling with diagnostic Cu-64 and therapeutic Lu-177 radiometal

  • Abhinav Bhise;Jeongsoo Yoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.45-49
    • /
    • 2022
  • With the development of monoclonal antibodies, therapeutic or diagnostic radioisotope has been successfully delivered at tumor sites with high selectivity for antigens. Different approaches have been applied to improve the tumor-to-normal ratio by considering the in vivo stability of radioimmunoconjugates as a prerequisite. Various stable and inert antibody radiolabeling techniques for radioimmunoconjugate preparation have been extensively evaluated to enhance in vivo stability. Antibody radiolabeling techniques should be rapid and easy; they should not disrupt the immunoreactivity and in vivo behavior of antibodies, which are coupled with a bifunctional chelator (BFC) to stably coordinate with a radiometal. For the design of BFCs, radiometal coordination properties must be considered. However, various diagnostic radionuclides, such as 89Zr, 64Cu, 68Ga, 111ln, and 99mTc, or therapeutic radionuclides, such as 177Lu, 67Cu, 90Y, and 225Ac, have been increasingly used for antibody radiolabeling. In addition to useful radionuclides, 64Cu and 177Lu with the most accessible or the highest production rates in many countries should be considered. In this review, we mainly discussed antibody radiolabeling techniques and conditions that involve 64Cu and 177Lu radiometals.

Characteristics of Total Carbon and Total Organic Carbon Using Elemental Analyzer in Hyung-Do Intertidal Zone Sediments (원소분석기를 이용한 형도 퇴적물의 총탄소 및 총유기탄소 특성)

  • Lee, Jun-Ho;Park, Kap-Song;Woo, Han-Jun
    • Economic and Environmental Geology
    • /
    • v.45 no.6
    • /
    • pp.673-684
    • /
    • 2012
  • Quantitative understanding of total carbon, total inorganic carbon and total organic carbon contained in ocean sediments is a basic data for interpretation of oceanic sediment environments. Elemental analyzer(EA) is frequently used for the analysis of carbon contents in inland soils and ocean sediments. Carbon and nitrogen contents of the soil reference material analyzed by an EA were 2.30% and 0.21% with standard deviations of 0.02 and 0.01, respectively. Relative standard deviations were 0.01 and 0.06, respectively, representing a high precision. Regression analysis of TOC and TC analysis results for the samples with TOC of less than 2.0% for the site in Hyung-Do showed a linear relationship with a slope of 0.9743($R^2$=0.9989, n=38), and the results of a relationship regression analysis between total organic carbon contents less than 0.5% and average grain size except for two samples showed a linear relationship with a slope of 0.0444($R^2$=0.6937 n=36). TOC contents of surface sediments were in the ranges of 0.10~1.67%(Average $0.26{\pm}0.37%$) with TOC values of 1.67% at S02 sampling site, 1.13% at S07 sampling site, and less than 1.00% at remaining sites. In the case of PC 01 core sediments, TOC showed the highest value of 0.20% near 70 cm. In the case of PC 02 core sediments, the highest value of 0.24% was indicated near 60 cm. The analysis method of organic carbon obtained from Hyung-Do Intertidal zone sediment sample results may be considered applicable to an organic carbon analysis for ocean sediments and useful for organic carbon analysis experiments of ocean sediments with a reduction in time required for the analysis and a high precision coupled with a high accuracy.

EPR SPECTRA OF Mn ION WITH TWO PHASES IN THE Y-Ba-Cu-Mn-O HIGH Tc SUPERCONDUCTOR

  • Kim, Seon-Ok;Rudowicz, Czeslaw;Lee, Soo-Hyung;Yu, Seong-Cho
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.782-785
    • /
    • 1995
  • In this paper, $Mn^{2+}$ ion was doped in Y-Ba-Cu-O as an EPR probe. The following samples were prepared by conventional solid-state reaction method : $YBa_{2}Cu_{2.96}Mn_{0.04}O_{7-\delta}$ (MN-I), annealed $YBa_{2}Cu_{2.96}Mn_{0.04}O_{7-\delta}$ (AMN) and $YBa_{2}Cu_{2.94}Mn_{0.06}O_{7-\delta}$ (MN-II). AMN sample was obtained from MN-I by annealing for 1 hr under the Ar gas atmosphere at $600^{\circ}C$. X-band (~9.05 GHz) EPR spectra were measured from 103 K to room temperature by employing a JES-RE3X spectroscopy with a $TE_{0.11}$ cylindrical cavity and 100 kHz modulation frequency. In MN-I we have observed only the $Cu^{2+}$ signal. The fact that no $Mn^{2+}$ signal was observed, in spite of $Mn^{2+}$ being a very sensitive EPR probe, indicates that most likely isolated $Mn^{2+}$ ions don't exist in the MN-I sample. Most probably $Mn^{2+}$ ions in the MN-I sample interact antiferromagnetically and hence are EPR silent. The AMN spectra of at room temperature and 103 K indicate not only the $Cu^{2+}$ signal but also an extra signal, which increases with decreasing temperature. It is suggested that the extra signal originates from Mn ions that were antiferromagnetically coupled before the annealing process. In MN-II, from 103 K to room temperature, also, the extra signal was observed together with the $Cu^{2+}$ signal. The extra signal in MN-II, however, decreases with decreasing temperature and nearly disappears at 103 K. The signal originates from Mn ions in impurity phases that include $Mn^{2+}$ ions. We suppose that there exist at least two $Mn^{2+}$ doped phases in Y-Ba-Cu-O. The $Mn^{2+}$ signal of one phase is undectable at all temperature and that of another phase decreases with decreasing temperature and disappears around 103 K.

  • PDF

Investigation of the Signal Characteristics of a Small Gamma Camera System Using NaI(Tl)-Position Sensitive Photomultiplier Tube (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 소형 감마카메라의 신호 특성 고찰)

  • Choi, Yong;Kim, Jong-Ho;Kim, Joon-Young;Im, Ki-Chun;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Joo, Koan-Sik;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.82-93
    • /
    • 2000
  • Purpose: We characterized the signals obtained from the components of a small gamma camera using Nal(Tl)-position sensitive photomultiplier tube (PSPMT) and optimized the parameters employed in the modules of the system. Materials and Methods: The small gamma camera system consists of a Nal(Tl) crystal ($60{\times}60{\times}6mm^3$) coupled with a Hamamatsu R3941 PSPMT, a resister chain circuit, preamplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a resistive charge division circuit which multiplexes the 34 cross wire anode channels into 4 signals (X+, X-, Y+, Y -). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated and digitized via triggering signal and used to localize the position of an event by applying the Anger logic. The gamma camera control and image display was performed by a program implemented using a graphic software. Results: The characteristics of signal and the parameters employed in each module of the system were presented. The intrinsic sensitivity of the system was approximately $8{\times}10^3$ counts/sec/${\mu}Ci$. The intrinsic energy resolution of the system was 18% FWHM at 140 keV. The spatial resolution obtained using a line-slit mask and $^{99m}Tc$ point source were, respectively, 2.2 and 2.3 mm FWHM in X and Y directions. Breast phantom containing $2{\sim}7mm$ diameter spheres was successfully imaged with a parallel hole collimator. The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We proposed a simple method for development of a small gamma camera and presented the characteristics of the signals from the system and the optimized parameters used in the modules of the small gamma camera.

  • PDF

Susceptibility Loci Associations with Prostate Cancer Risk in Northern Chinese Men

  • Wang, Na-Na;Xu, Yong;Yang, Kuo;Wei, Dong;Zhang, Yao-Guang;Liu, Ming;Shi, Xiao-Hong;Liang, Si-Ying;Sun, Liang;Zhu, Xiao-Quan;Yang, Yi-Ge;Tang, Lei;Zhao, Cheng-Xiao;Wang, Xin;Chen, Xin;Hui, Juan;Zhang, Yu-Hong;Zhu, Ling;Yang, Fan;Zhang, Yu-Rong;Yang, Ze;Wang, Jian-Ye
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3075-3078
    • /
    • 2013
  • Background: KLK3 gene products, like human prostate-specific antigen (PSA), are important biomarkers in the clinical diagnosis of prostate cancer (PCa). G protein-coupled receptor RFX6, C2orf43 and FOXP4 signaling plays important roles in the development of PCa. However, associations of these genes with PCa in northern Chinese men remain to be detailed. This study aimed to investigate their impact on occurrence and level of malignancy. Methods: All subjects were from Beijing and Tianjin, including 266 cases with prostate cancer and 288 normal individuals as controls. We evaluated associations between clinical covariates (age at diagnosis, prostate specific antigen, Gleason score, tumor stage and aggressive) and 6 candidate PCa risk loci, genotyped by PCR- high resolution melting curve and sequencing methods. Results: Case-control analysis of allelic frequency of PCa associated with PCa showed that one of the 6 candidate risk loci, rs339331 in the RFX6 gene, was associated with reduced risk of prostate cancer (odds ratio (OR) = 0.73, 95% confidence interval (CI) =0.57-0.94, P = 0.013) in northern Chinese men. In addition, subjects with CX (CC+TC) genotypes had a decreased risk for prostrate cancer compared to those carrying the TT homozygote (OR =0.64, 95% CI = 0.45- 0.90, P = 0.008). The TT genotype of 13q22 (rs9600079, T) was associated with tumor stage (P=0.044, OR=2.34, 95% CI=0.94-5.87). Other SNPs were not significantly associated with clinical covariates in prostate cancer (P > 0.05). Conclusions. rs339331 in the RFX6 gene may be associated with prostate cancer as a susceptibility locus in northern Chinese men.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF