• 제목/요약/키워드: TAP device

검색결과 59건 처리시간 0.021초

유비쿼터스 기반 분산 자율 전압 제어 방식에 의한 배전계통 전압 보상 전략 (The Voltage Compensation Strategy of Distribution System Using the Ubiquitous-based Distributed Voltage Control Method)

  • 고윤석
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1696-1702
    • /
    • 2008
  • This paper proposes a voltage compensation device direct control strategy to realize the distributed, autonomous voltage control of the distribution system, which based on voltage data collected from customers of the remote site under the ubiquitous-based distribution system. In the proposed method, The ULTC and the SVR(Step Voltage Regulator)s compensate autonomously the voltage for self-compensation area based on the voltage data furnished from the ubiquitous device of customers. Also, the SVRs overcome the limit of single-operation of ULTC by the interlocking operation with the ULTC and enhance the voltage compensation capability for the customer. In particular, an optimization design method and a fuzzy design method are compared to determine the effective control method of the voltage compensator under the ubiquitous-based on-line operation environments. In fuzzy method, the tap of voltage compensator is defined as output member. Finally, the proposed two methods are implemented in Visual C++ MFC, the effectiveness is proved by simulation based on the worst virtual voltage data. Also, an optimal voltage compensation strategy is determined under on-line environments based on analyzed results.

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

WDM 광통신망을 위한 저가형 광신호 삽입/추출 모듈 구현 (Low cost optical add/drop module for WDM optical communication networks)

  • 이상화;송해상;안대영
    • 한국정보통신학회논문지
    • /
    • 제7권8호
    • /
    • pp.1816-1822
    • /
    • 2003
  • 광섬유 브라그 격자와 광 분기 결합기로 구성된 새로운 구조의 파장 선택형 광신호 삽입/추출 모듈을 제안하였다. 제안된 광신호 삽입/추출 모듈은 동일한 동작을 수행하는 기존의 모듈에 비해 매우 단순한 구조를 가지고 있으며 초저가로 구현이 가능하다는 장점을 갖고 있다. 제안한 모듈의 동작 특성을 실험적으로 측정 및 분석한 결과, 155Mbps급의 전송속도를 갖는 WDM 전송 시스템 내에서 no­crosstalk power penalty를 가짐을 확인하였다 출력 단에서 투과되는 채널의 삽입 손실은 3.5㏈ 이하이었고 추출 단으로 추출되는 신호의 삽입 손실은 21㏈ 이하로 비교적 높은 값을 가졌다. 반면에 추출된 신호의 채널 소광비는 15㏈ 이상이었고 투과되는 신호의 채널 소광비는 26㏈ 이상으로 상용화된 모듈과 비교해 거의 비슷한 수준의 값을 가짐을 확인하였다.

광섬유 bragg grating을 이용한 가변형 add/drop 필터에 관한 연구 (A study on tunable Add/Drop filter using Fiber Bragg Gratings)

  • 박무윤;박광노;이경식;원용협;이상배
    • 전자공학회논문지S
    • /
    • 제34S권5호
    • /
    • pp.15-24
    • /
    • 1997
  • We propose a tunable add/drop filter in a form of an all-fiber mach-zehnder interferometer iwth one bragg grating at each arm. This device can be tuned by inducing a strain in the bragg grating. We also theoretically analyze the outut characteristics of the tunable add/drop filter. As a result of simulation, we know that the proposed tunable add/drop filter works well. When 2*10$^{-3}$ of strain is induced, the reflected spectrum shifts about 3nm. And its reflected spectral width is about 0.3nm. In this case roughly 5 channels can be tuned, assuming the channel spacing is 0.3nm. When the pathlengths of the both arms are not the same, the transmissivities at the add and output ports and the reflectivity at the tap port varies sinusoidally with the pthlength difference. To maintain the transmissivities above 90% in the wavelength tuning range of 20nm the pathlength difference less than 16.mu.m is required.

  • PDF

변전소 전압안정화를 위한 STATCOM과 기존 조상 설비간의 지역 무효전력 협조제어에 관한 연구 (A Study on Local Coordinative Reactive Power Control between STATCOM and Other Reactive Power Controllers for Voltage Stability Improvement at Substation)

  • 정기석;장병훈;이현철;이근준;백영식
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.525-530
    • /
    • 2010
  • Installation of FACTS(Flexible AC Transmission System) device can maximize utilization of existing power facilities and reliability of power system. STATCOM has excellent characteristics in operating cost, maintaining facilities, loss and so on. However, STATCOM has a disadvantage of facility cost over capacity. So it is effective to coordinate STATCOM and existing external bank(capacitor and reactor) and OLTC(On Load Tap Changer). This paper mainly proposes coordinative control method between STATCOM installed within substation and other reactive power resources including Shunt Reactors and Shunt Capacitors and OLTC for voltage stability improvement. The proposed coordinative control method is developed for the STATCOM of Mi-gum substation and the simulation results of EMTP/RV model show the effectiveness of the proposed method.

반도체 스위칭 소자의 트리거 특성을 이용한 배터리 자동 충전회로에 관한 연구 (A study on the auto-charging circuit of the battery power units using trigger characteristics of semiconductor device)

  • 김영민;황종선;박성진;임종연;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.519-522
    • /
    • 2001
  • Recently, the battery charging technology and reducing technology of harmonics on AC input line are rising importantly according to increasing electrical facilities that it has been replaced battery with emergency power. In this study, I proposed that an auto-charging circuit of battery has low cost with simple-construction circuit, relative, harmonics reduction with diode tap-change method, high reliability of system for using characteristics of thyristor switching. In case of this circuit, convenience and reliability of maintenance of battery power units were more improved. 1 think that it is resulted in effect of prevention to shortening of battery life from over-charging and over-discharging and decrease of harmonics obstacle on AC input line.

  • PDF

기기 수명을 고려한 배전계통 커패시터의 설치 계획 (Optimal Capacitor Placement in a Distribution System Considering Lifetimes of Devices)

  • 박종영;박종근
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.164-171
    • /
    • 2008
  • This paper proposes the planning method for placement of capacitors in a distribution system. The main objectives in the planning for capacitor allocation are the reduction of installation costs and electric power loss. In the proposed method, the life time of each device is considered in calculating installation costs, and the optimal operation status of devices is found by genetic algorithm. Then, the optimal numbers and locations are determined based on the optimal operation status. Simulation results in the 69-bus distribution system show that the proposed method performs better than conventional methods.

전압, 무효전력 제어를 위한 전문가 시스템 (An Expert System for Voltage and Reactive Power Control)

  • 서승우;이흥재;박영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.852-854
    • /
    • 1988
  • An expert system is developed to solve the voltage problems occurring in electric transmission power system. It is based on knewledge engineering technique satisfies the performance criteria such as minimizing the number of operation of control device and quantity of reactive power. Also, it uses best-first search technique from the experts. Control devices used in this paper include shunt capaciter/reactor, transformer tap changer, generator output voltage and a generator is used after the availability of other two devices are checked.

  • PDF

Effect of Tactile Feedback for Button GUI on Mobile Touch Devices

  • Shin, Heesook;Lim, Jeong-Mook;Lee, Jong-Uk;Lee, Geehyuk;Kyung, Ki-Uk
    • ETRI Journal
    • /
    • 제36권6호
    • /
    • pp.979-987
    • /
    • 2014
  • This paper describes new tactile feedback patterns and the effect of their input performance for a button GUI activated by a tap gesture on mobile touch devices. Based on an analysis of touch interaction and informal user tests, several tactile feedback patterns were designed. Using these patterns, three user experiments were performed to investigate appropriate tactile feedback patterns and their input performance during interaction with a touch button. The results showed that a tactile pattern responding to each touch and release gesture with a rapid response time and short falling time provides the feeling of physically clicking a button. The suggested tactile feedback pattern has a significantly positive effect on the number of typing errors and typing task completion time compared to the performance when no feedback is provided.

A Case of Peritoneal Dialysis-related Peritonitis Caused by Aeromonas Hydrophila in the Patient Receiving Automated Peritoneal Dialysis

  • Kim, Hyun Jin;Park, Hyun Sun;Bae, Eunsin;Kim, Hae Won;Kim, Beom;Moon, Kyoung Hyoub;Lee, Dong-Young
    • 대한전해질대사연구회지
    • /
    • 제16권2호
    • /
    • pp.27-29
    • /
    • 2018
  • Peritoneal dialysis (PD)-related peritonitis is a major cause of injury and technique failure in patients undergoing PD. Aeromonas hydrophila is ubiquitous in the environment, and is a Gram-negative rod associated with infections in fish and amphibians in most cases; however, it can also cause opportunistic infections in immunocompromised patients. We report a case of A. hydrophila peritonitis in a 56-year-old male on automated PD. Peritonitis may have been caused by contamination of the Set Plus, a component of the automated peritoneal dialysis device. Although Set Plus is disposable, the patient reused the product by cleansing with tap water. He was successfully treated with intraperitoneally-administered ceftazidime and has been well without recurrence for more than 2 years.