• Title/Summary/Keyword: TAB

Search Result 374, Processing Time 0.027 seconds

A Comparative Study of the Security Prevention Strategies on Arson: Focused on the Behavioral Characteristics between Serial Arsonists and Simple Arsonists (방화범죄의 경비예방 전략에 관한 비교연구 - 연쇄방화범과 단순방화범의 행위적 특성을 중심으로 -)

  • You, Wan-Seok;Hwang, Sung-Hyun
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.139-162
    • /
    • 2011
  • The purpose of this study is to compare with the general and behavioral characteristics between simple and serial arsonists using the data derived from Scientific Crime Analysis System, Criminal Filing Search System, and Crime Information Management System. The analysis and findings reported here are derived from data extracted from 160 arsonists arrested by police officer. The independent variables included such socio-economic characteristic as arsonists' gender, age, occupation, education level, and previous criminal records of arsonists, and finally the general characteristics of the scene of fire settings. The dependent variable is whether or not serial fire setter. To achieve the purpose, the analysis of frequencies and cross-tab were conducted. According to frequence and cross-tab analysis, there are great differences of the general and behavior characteristics between two groups. In the comparison of simple and serial arsonists, serial arsonists are more likely to have previous criminal records, low socio-economic status, unmarried and no cohabitants than simple arsonists. furthermore, serial arsonists are more likely to use garbage papers for fire setting in the scene of the crime, to have mental or psychological problems, and to get involved in fire setting for the psychological pleasure than simple arsonists do. The present research has some obvious limitations. First, the analysis is based only on arsonists arrested by police officers. These may be considerable differences in arsonists arrested by police officers and fire setters not arrested by them. Additional research is needed to assess the extent to which these findings would apply to fire setters not arrested by police officer in Korea. Secondly, the data in this study are cross-sectional and simple cross-tab analysis are used. Potential limitation of cross-sectional data concerns the inability to specify the changes in measures as arsonists behavioral characteristics. Therefore, further studies need to use longitudinal data and more complicate statistical techniques such as correlation analysis, multiple regression analysis, or LISREL models to specify the casual relationships between dependent and independent variables for fire settings. Even if this study has some limitations, it is meaningful in which it first investigated the comparison of simple and serial arsonists focusing on the general and behavioral characteristics between two groups in Korea.

  • PDF

Microbial Monitoring and Exploring Ways to Prevent or Minimize Microbial Contamination at the Production and Distribution Stages of Fresh Strawberries (신선한 딸기의 생산 및 유통 단계에서의 미생물 모니터링 및 미생물 오염 방지 또는 저감화 방법 모색)

  • Kim, Sol-A;Lee, Jeong-Eun;Kim, Go-Un;Kim, Soo-Hwan;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.6
    • /
    • pp.485-492
    • /
    • 2017
  • This study investigated to determine the microbial contamination levels of strawberries at harvest and distribution stages and to suggest a control measure for reducing the microbial contamination of strawberries by replacing worker's gloves used at harvest and distribution stages. According to the monitoring results, the contamination levels of total aerobic bacteria (TAB) were in the order of soil ($7.12{\pm}0.61{\log}_{10}CFU/g$), gloves ($6.06{\pm}1.80{\log}_{10}CFU/cm^2$), strawberry ($3.28{\times}0.98{\log}_{10}CFU/g$), and water ($3.08{\pm}0.55{\log}_{10}CFU/g$) at harvest stage. TAB of strawberry at was harvest stage reduced from $3.28{\pm}0.98{\log}_{10}CFU/g$ to $1.85{\pm}0.21{\log}_{10}CFU/g$ and $2.6{\pm}0.30{\log}_{10}CFU/g$ at cold and room temperature storage, respectively. By the replacement of worker's gloves and distribution temperature, TAB levels of the strawberries were significantly reduced when compared to those of the strawberries treated without replacement of worker's gloves and distributed at room temperature. For reusing the replaced gloves, washing with a commercial disinfectant, clorox, was effective to reduce microorganisms contaminated on the worker's gloves. These results demonstrated that appropriate replacement of gloves at the harvest and distribution stages is an effective method for reducing microbial contamination of fresh strawberries.

A Study on the Development of Basic Brassiere Pattern for Adult Women(Part II)-Focusing on Pattern Grading- (성인여성용 브래지어 원형 개발연구(제2보) -패턴그레이딩을 중심으로-)

  • 박은미;손희순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.821-832
    • /
    • 2002
  • The purpose of this study was to develop grading method of the basic brassiere patterns therewith, provide for 12 size's brassiere patterns and prove fitness of their's and shape. The collected data were statistically processed using the SAS 6.12 for Means, Standard Deviation, etc. The results of this study can be summarized as follows; 1. The basic sizes adopted at the first design stage (see fig.1-2) were 75AA, 75A and 75B each of which was designed as upper foundation basic pattern in reference to the cup size. At the second stage, each of the upper body foundation basic pattern was used to design lower cup, upper up, front panel and wing in their order(see fig.3-6). At the third stage, the other sizes were graded in reference to the three brassiere patterns (75AA, 75A and 75B) to produce 12 brassiere sizes(see Tab. 7-8). In order to develop the basic patterns of adult women's brassieres, 33 women were selected per 11 size combination(3 women per size combination), and then, their brassiere fitting was teated. As a result, the fronts of the basic patterns were found to have such problems as undone front center, poor levelling of upper cup's bottom line or lower cup's top line, poor shape of upper cup's outside top line and shoulder strip position. On the other hand, on the rear side of the basic patterns, the central part of the wing was slightly lifted, while the wing width and straps'interval did not befit the ful1-cup brassiere. The result of this first brassiere fitting test showed that the functionality and aesthetics of the basic pattern brassieres were more or less satisfactory, and thus, the problems were addressed for the second teat. In the second test, the aesthetics, breast-shaping effect and functionality of the basic pattern brassieres were much improved. 2. We were to present the final brassiere sizing system to extend the interior length of breast and the exterior length of breast on the basis of fitting test. Thereby, 75B$.$80A$.$80B$.$85A$.$85B's the interior lengths of breast were enlarged to 0.7cm, the rest size was enlarged to 0.5cm and the exterior length of breast was enlarged to 0.5cm regardless of sizes. 3. The upper foundation basic patterns of 75AA and 75B were presented and and the basic brassiere pattern and grading pattern were presented through to.

Seismic Retrofit of Welded Steel Moment Connections Considering the Presence of Composite Floor Slabs (바닥슬래브를 고려한 용접철골모멘트접합부의 내진보강)

  • Lee, Cheol Ho;Kim, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.25-36
    • /
    • 2017
  • In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange was prevalent. The presence of a concrete slab and resulting composite action was speculated as one of the critical causes of the prevalent bottom flange fracture. In this study, four seismic retrofit schemes are proposed in order to salvage welded steel moment connections with composite floor slabs in existing steel moment frames. Because top flange modification of existing beams is not feasible due to the presence of a concrete floor slab, three schemes of bottom flange modification by using welded triangular or straight haunches or RBS(reduced beam section), and beam web strengthening by attaching heavy shear tab were cyclically tested and analyzed. Test results of this study show that haunch and web-strengthened specimens can eliminate the detrimental effect caused by composite action and ensure excellent connection plastic rotation exceeding 5% rad. Design recommendations for each retrofit scheme together with supplemental numerical studies are also presented.

ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES (가시광선영역에서 shade guide에 따른 광투과도 특성 연구)

  • Choi, Keun-Bae;Park, Charn-Woon;Song, Chang-Yong;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Seismic Behavior of Non-Seismic Concentrically Braced Frames with Shared Shear tab (쉬어탭 공유 접합부를 갖는 비내진중심가새골조의 내진거동)

  • Yeom, Hee Jin;Jung, Eun Bi;Yoo, Jung Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.323-332
    • /
    • 2015
  • Special concentrically braced frames(SCBFs) have distinctive advantages in considerable seismic performance, which make engineers widely use SCBFs as lateral-load resisting systems in buildings and have researchers to develop SCBFs design methods. Compared to the extensive research of SCBF, comparatively little information is currently available on the performance of SCBFs designed and constructed before the early 1990's. Prior to 1988, concentrically braced frames(CBFs) design requirements were substantially less restrictive. As a result, many existing structures designed to these requirements may not ensure ductility and pose a significant concern in current buildings. In this study, these older frames are referred as non-seismic braced frames(NCBFs). In order to investigate the seismic behavior of NCBFs, finite-element(FE) models of SCBF and NCBF were suggested and verified using case investigation of NCBF conducted on the University of Washington. Using these models, the seismic behavior of NCBF with shared welding shear tab, which is the representative of the types of connections, was established and compared with the seismic performance of SCBF.

Proposal of Connection Details for a Double Split Tee Connection Without a Shear tap (전단탭이 없는 상·하부 스플릿 티 접합부의 접합부상세 제안)

  • Yang, Jae Guen;Lee, Hyung Dong;Kim, Yong Boem;Pae, Da Sol
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.423-433
    • /
    • 2015
  • A double split tee connection, which is a beam-column moment connection, shows different behavioral characteristics under the influences of the thickness of a T-stub flange, a high-strength bolt gauge distance, and the number and diameter of a high-strength bolt. A double split tee connection is idealized and designed that a flexural moment normally acting on connections can be resisted by a T-stub and a shear force by a shear tap. However, where a double split tee connection is adopted to a low-and medium-rise steel structure, a small-sized beam member can be adopted. Then, a shear tab may not be bolted to the web of a beam. This study was conducted to suggest the details of a connection to secure that a double split tee connection with a geometric shape has a sufficient capacity to resist a shear force. To verify this, this study was conducted to make a three-dimensional nonlinear finite element analysis on a double split tee connection.

A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas- (제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로)

  • 엄병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.

Sterilization of Rapeseed Sprouts by Intense Pulsed Light Treatment (고강도 광원을 이용한 새싹 채소의 살균)

  • Park, Heeran;Cha, Gyung-Hee;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.36-41
    • /
    • 2016
  • In this study, the effects of intense pulsed light (IPL) treatment on microbial inactivation and quality in rapeseed sprouts were investigated. Untreated rapeseed sprouts exhibit a high level of total aerobic bacteria (TAB) ($1.2{\times}10^7CFU/g$), coliform bacteria (coliform) ($3.3{\times}10^6CFU/g$), and pathogenic E. coli (PE) ($2.1{\times}10^5CFU/g$). The microorganisms found on rapeseed sprouts decreased with exposure to increasing light intensity and treatment time. The greatest reduction in microbial content was observed with a treatment of 1000 V, 5 pps for 10 min, where TAB, coliform, and PE levels decreased to 1.0 log CFU/g, 1.6 log CFU/g, and 1.8 log CFU/g, respectively. In agreement with these data, the microbial inactivation rate increased with the increase in the distance between the light source and the samples during IPL treatment. After IPL treatment of rapeseed sprouts, water content and vitamin C content decreased.