• Title/Summary/Keyword: T3SS

Search Result 548, Processing Time 0.031 seconds

Evaluation of Water Quality and Phytoplankton Community Using a Multivariate Analysis in Bukhan River (다변량 통계분석을 이용한 북한강의 수질 및 식물플랑크톤 군집 특성 평가)

  • Kim, Hun Nyun;Youn, Seok Jea;Byeon, Myeong Seop;Yu, Soon Ju;Im, Jong Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • The purpose of this study is to evaluate the water quality and phytoplankton community in Bukhan River which account for 44.4 % of the total inflow into Lake Paldang, using multivariate statistical techniques (i.e., correlation analysis, principal component analysis (PCA)/factor analysis (FA)). Water samples were collected from March to November 2015 and the following parameters measured; water temperature, pH, DO, EC, SS, BOD, Chl-a, COD, TN, $NO_3-N$, $NH_3-N$, TP, DTP, $PO_4-P$, and phytoplankton community. The water quality of the main stream and the tributaries were not significantly different apart from the relatively high concentration of BOD, COD and nutrients recorded in MH. The highest cell density of Stephanodiscus hantzschii and Merismopedia glauca dominated phytoplankton was observed in PD. Based on the correlation analysis, total phytoplankton and cyanophyceae were highly correlated with BOD, COD and nutrients. PCA/FA resulted in four main factors accounting for 82.240 % of the total variance in the water quality dataset. The group of component 1 (TN, DTN, DO, $NO_3-N$, water temperature) and component 2 ($PO_4-P$, T-P, DTP, SS) were classified as nutrient element factor whereas component 3 (Chl-a, COD, BOD, $NH_3-N$, pH) was related to organic substances. Hence, the identification of the main potential environmental pollution factors in Bukhan River will help policy makers make better and more informed decisions on how to improve the water quality.

Carcass traits, fatty acid composition, gene expression, oxidative stability and quality attributes of different muscles in Dorper lambs fed Nigella sativa seeds, Rosmarinus officinalis leaves and their combination

  • Odhaib, Kifah Jumaah;Adeyemi, Kazeem Dauda;Sazili, Awis Qurni
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1345-1357
    • /
    • 2018
  • Objective: This study examined the influence of dietary supplementation of Nigella sativa seeds, Rosmarinus officinalis leaves and their combination on carcass attributes, fatty acid (FA) composition, gene expression, lipid oxidation and physicochemical properties of longissimus dorsi (LD), semitendinosus (ST), and supraspinatus (SS) muscles in Dorper lambs. Methods: Twenty-four Dorper lambs ($18.68{\pm}0.6kg$, 4 to 5 months old) were randomly assigned to a concentrate mixture containing either, no supplement (control, T1), 1% Rosmarinus officinalis leaves (T2), 1% Nigella sativa seeds (T3), or 1% Rosmarinus officinalis leaves+1% Nigella sativa seeds (T4) on a dry matter basis. The lambs were fed the treatments with urea-treated rice straw for 90 days, slaughtered and the muscles were subjected to a 7 d postmortem chill storage. Results: The T2 lambs had greater (p<0.05) slaughter and cold carcass weights than the control lambs. Dietary supplements did not affect (p>0.05) chill loss, dressing percentage, carcass composition, intramuscular fat and muscle pH in Dorper lambs. Meat from supplemented lambs had lower (p<0.05) cooking and drip losses, shear force, lightness, and lipid oxidation and greater (p<0.05) redness compared with the control meat. The impact of dietary supplements on muscle FA varied with muscle type. Diet had no effect (p>0.05) on the expression of stearoyl-CoA desaturase and lipoprotein lipase genes in LD and ST muscles in Dorper lambs. The T2 and T3 diets up regulated the expression of AMP-activated protein kinase alpha 2 gene in LD and ST muscles and up regulated the expression of sterol regulatory element-binding protein 1 in ST muscle in Dorper lambs. Conclusion: Dietary supplementation of Nigella sativa seeds and Rosmarinus officinalis leaves had beneficial effects on meat quality in Dorper lambs.

DNA Polymorphisms in SREBF1 and FASN Genes Affect Fatty Acid Composition in Korean Cattle (Hanwoo)

  • Bhuiyan, M.S.A.;Yu, S.L.;Jeon, J.T.;Yoon, D.;Cho, Y.M.;Park, E.W.;Kim, N.K.;Kim, K.S.;Lee, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.6
    • /
    • pp.765-773
    • /
    • 2009
  • Sterol regulatory element binding factor 1 (SREBF1) and fatty acid synthase (FASN) genes play an important role in the biosynthesis of fatty acids and cholesterol, and in lipid metabolism. This study used polymorphisms in the intron 5 of bovine SREBF1 and in the thioesterase (TE) domain of FASN genes to evaluate their associations with beef fatty acid composition. A previously identified 84-bp indel (L: insertion/long type and S: deletion/short type) of the SREBF1 gene in Korean cattle had significant associations with the concentration of stearic (C18:0), linoleic (C18:2) and polyunsaturated fatty acids (PUFA). The stearic acid concentration was 6.30% lower in the SS than the LL genotype (p<0.05), but the linoleic and PUFA contents were 11.06% and 12.20% higher in SS compared to LL (p<0.05). Based on the sequence analysis, five single nucleotide polymorphisms (SNPs) g.17924G>A, g.18043C>T, g.18440G>A, g.18529G>A and g.18663C>T in the TE domain of the FASN gene were identified among the different cattle breeds studied. Among these, only g.17924 G>A and g.18663C>T SNPs were segregating in the Hanwoo population. The g.17924G>A SNP is a non-synonymous mutation (thr2264ala) and was significantly associated with the contents of palmitic (C16:0) and oleic acid (C18:1). The oleic acid concentration was 3.18% and 2.79% higher in Hanwoo with the GG genotype than the AA and AG genotypes, respectively (p<0.05), whereas the GG genotype had 3.8% and 4.01% lower palmitic acid than in those cattle with genotype AA and AG, respectively (p<0.05). Tissue expression data showed that SREBFI and FASN genes were expressed in a variety of tissues though they were expressed preferentially in different muscle tissues. In conclusion, the 84-bp indel of SREBF1 and g.17924G>A SNP of the FASN gene can be used as DNA markers to select Hanwoo breeding stock for fatty acid composition.

Estimation of Water Purification Ability with Applying Porous Concrete to Weir and Riverbed Materials (다공성 콘크리트의 보 및 하상재료 적용에 따른 하천 수질정화 능력 평가)

  • Choi, I-Song;Kim, Jin-Hong;Choi, Gye-Woon;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1013-1023
    • /
    • 2003
  • This study was performed to improve water quality of stream by applying hydraulic structures (weir and river bed material) made of porous concrete. The physical and chemical characteristics of porous concrete were measured to estimate application possibility of it in hydraulic structures and it was considered as a proper material for the hydraulic structures. In the results of comparison for the component of matters attached on the hydraulic structures made of porous and ordinary concrete, DW (dry weight) amount attached on porous concrete was 1.6 times higher than that on ordinary concrete under the condition of the same flow rate but influence by flow rate (difference of 10 times) was not shown. Therefore, we could understand that the material of media was more important in DW amount than flow rate. The rate of AFDM (ash free dry mass) to DW also was more at porous concrete than at ordinary concrete. Especially, the high rates of nitrogen and phosphorous in matters attached on porous concrete verify that they were removed by assimilation, adsorption and metabolism of periphyton. The removal percentage of SS, BOD, COD, T-N and T-P by hydraulic structures applying porous concrete compared with ordinary concrete was increased by 34.6%, 36.9%, 33.9%, 18.3% and 21.6%, respectively. Therefore, applying porous concrete to hydraulic structure is expected to contribute to improvement of stream water quality.

Optimum Depth and Volume Ratio of Aerobic to Anaerobic Bed for Development of Small-Scale Sewage Treatment Apparatus by Natural Purification Method (자연정화공법에 의한 소형 하수처리장치 개발을 위한 최적 깊이 및 호기.혐기 비율)

  • Seo, Dong-Cheol;Park, Mi-Ryoung;Kwak, Nae-Woon;Hwang, Ha-Na;Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.1
    • /
    • pp.14-24
    • /
    • 2006
  • To develop small-scale sewage treatment apparatus for detached house of agricultural village, a small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic bed was constructed. To reduce the area of a sewage treatment apparatus, four different fitter media were used and each filter medium was coarse sand, broken stone, steel slag, and mixed fitter media (coarse sand : broken stone : steel slag = 1:1:1). The efficiency of sewage treatment according to the depth of aerobic and anaerobic bed and the volume ratio of aerobic to anaerobic bed were investigated in small-scale sewage treatment apparatus. The removal rate of pollutants according to the depth of aerobic and anaerobic bed in small-scale sewage treatment apparatus was high in the order of 50 cm < 70 cm < 90 cm. The removal rate of pollutants according to the ratio of aerobic to anaerobic bed in small-scale sewage treatment apparatus was high in the order of 1:1 < 1:2 $\fallingdotseq$ 1:3. Under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P were $98{\sim}99,\;95{\sim}97,\;99,\;65{\sim}66\;and\;96{\sim}99%$ respectively, in small-scale sewage treatment apparatus.

Evaluation of the Reducing Efficiency of Vertical and Horizontal Wetland Using Intermittent Flow System (간헐식 흐름방식을 활용한 수직·수평 습지의 정화효율 평가)

  • Joo, Kwang Jin;Lee, Dong Min;Kim, Ki Jung;Cho, Yong Chul;Jang, Gwang Hyeon;Choi, I Song;Oh, Jong Min
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.3
    • /
    • pp.142-148
    • /
    • 2017
  • Nitrogen and phosphorus are key factors in causing eutrophication of water body. In this study, ceramics media was selected to increase the removal efficiency of nitrogen and phosphorus. We designed vertical, horizontal flow constructed wetlands to create aerobic and anaerobic flow conditions by using the media, then proceeded to performance evaluations after acrylic reactors were produced. In the case of vertical and horizontal flow constructed wetlands, we measured oxygen concentrations to evaluate aerobic and anaerobic conditions. we got the result of 2.7 mg/L in the aerobic condition, N.D in the anaerobic condition respectively, which suited our purpose. The result of the combined vertical and horizontal flow condition showed that the removal efficiency of SS was 94%, 91%, 61% at 140 min, 80 min, 60 min of running times, respectively, and the removal efficiency of T-P was 84%, 71%, 63% during each running time. In case of T-N, the removal efficiency was 63%, 49%, 42% during each running time. We found that the reactor exerted better removal efficiency when in the short time compared to 12 - 24 hr residence time of existing wetlands. In this study, we conducted experiments to explore functional effects after applying combined vertical and horizontal flow methods in the field. Further study will be carried out to identify its mechanism and administrative perspective.

The Treatment of Domestic Wastewater by Coagulation-Crossflow Microfiltration (응집-정밀여과에 의한 도시하수의 처리)

  • Sim, Joo-Hyun;Kim, Dae-Hwan;Seo, Hyung-Joon;Chung, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.581-589
    • /
    • 2005
  • Recently, membrane processes have been replacing the conventional processes for waste water treatment to produce better quality of effluent and to meet more stringent regulations because of water shortage. However, using membrane processes for water treatment has confronted with fouling and difficulty in treating dissolved organic pollutants. In this study, membrane process equipped with crossflow microfiltration is combined with coagulation process using alum and PAC to improve permeability and treatment efficiency. The effects of coagulant dosage and optimum membrane operating conditions were investigated from measurement of permeate flow, cumulative volume, total resistance, particle size, dissolved organic pollutant, dissolved aluminium and quality of effluent. Characteristic of PAC coagulation was compared with that of alum coagulation. PAC coagulation reduced membrane fouling because of forming larger particle size and increased permeate velocity and cumulative volume. Less dissolved organic pollutants and dissolved aluminum made decreasing-rate of permeate velocity being lowered. At using $0.2\;{\mu}m$ membrane, cake filtration observed. At using $0.45\;{\mu}m$ membrane, there was floc breakage due to shear stress occurred born circulating operation. It made floc size smaller than membrane pore size, which subsequently to decrease permeate velocity and to increase total resistance. The optimum coagulation dosage was $300{\pm}50\;mg/L$ for both alum and PAC. PAC coagulation was more efficiently used with $0.2\;{\mu}m$ membrane, and the highest permeate flux was in using $0.45\;{\mu}m$membrane. The greatest efficiency of treatment was as follows; turbidity 99.8%, SS 99.9%, $BOD_5$ 94.4%, $COD_{Cr}$ 95.4%, T-N 54.3%, T-P 99.8%.

Characteristics of Non-Point Pollutants from Forest Landuse (산림 지역의 비점오염물질 유출 특성)

  • Kim, Ji-Yeon;Kim, Jee-Hyun;Jung, Min-Kyoung;Ji, Yong-Dea;Hwang, Jae-Yup;Park, Soo-Young;Yu, Jay-Jung;Kim, Tae-Seung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.287-287
    • /
    • 2011
  • 모니터링 자료의 부족으로 인하여 다양한 토지이용에서 발생하는 비점오염물질의 관리에 어려움을 겪고 있는 실정이다. 현재 환경부에서는 현행 토지계의 원단위를 세부적으로 분류하여 재산정하기 위하여 지목별로 장기 모니터링이 수행되고 있다. 특히, 산림 지역의 경우 도시 및 축산지역에 비하여 강우유출수의 농도는 낮더라도 유량적인 측면에 보았을 때 전체 수계에 대한 부하량 기여도는 매우 높다고 볼 수 있다. 따라서 본 연구는 장기모니터링의 일환으로 산림지역에 대한 비점오염물질 유출 특성을 파악하기 위하여 모니터링 및 분석을 실시하였으며, 이러한 결과는 향후 비점오염원 평가기반을 마련하고자 한다. 본 연구는 활엽수지역을 대상으로 2010년 4월부터 10월까지 총 16회에 걸쳐 모니터링이 수행되었으며, 시료의 성분 변화를 막기 위해 냉장기능이 있는 자동채수기를 이용하여 시료를 채취하였다. 수질분석항목은 BOD, COD, DOC, SS, T-N, $NO_3$-N, $NH_3$-N, T-P, $PO_4$-P로 총 9가지 항목을 분석하였다. 강우사상에 대한 모니터링 결과, 총강우량은 7.0~76.5mm, 강우지속시간은 1~30hr, 평균 강우강도는 0.88~18.50mm/hr의 범위를 보이고 있으며, EMC(Event Mean Concentration, 유량가중평균농도)결과 BOD는 0.4~2.4mg/L, T-N은 1.156~14.777mg/L, T-P는 0.009~0.562mg/L인 것으로 나타났으며, SS는 1.8~71.9mg/L 로 비교적 높은 값을 나타내는 것으로 분석되었다. 농도 변화 및 유출경향의 패턴을 볼 때, 유량이 증가함에 따라 농도도 점점 증가하여 첨두유량이 발생된 후 감소하는 경향을 나타내는 것으로 분석되었다. 또한 우리나라의 경우, 시험유역을 대개 산지 소유역에 설치하는 경우가 많아서 일반적으로 지연시간이 짧은 경우가 많기 때문에 이 지역 역시 강우가 내린 후 계류유출량의 증가에 영향을 주는 강우의 유출속도는 비교적 빠른 것으로 나타났다. 그리고 단기 수문곡선상에서 강우량이 많을 시 유출이 빠르게 일어나 첨두 유량에 도달하는 시간이 짧고, 강우량이 적을 시에는 첨두 유량의 출현시간이 늦어지는 것을 볼 수 있었다.

  • PDF

Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling (모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구)

  • Lee, Hyunseop;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.251-256
    • /
    • 2019
  • In the upstream and nearby areas of the water source, there are many areas where the sewerage penetration rate is relatively low due to development restrictions. This has been continuously affecting the pollution of the water source. As a measure to prevent this, method of distributing sewage and improving existing facilities are suggested. In this study, A MWTP(Municipal Watewater Treatment Plant) using the Air-vent SBR process located at upstream of An-dong and Im-ha Dam was selected as a modeling facility. And, the retrofit method to improve the effluent from RCSTP(Rural Community Sewage Tratment Plant) was induced based on A MWTP modeling result. The model construction and verification were carried out based on the operating data for 5 years (2012 ~ 2016). As a result, it was analyzed that the water quality of the effluent during the winter could be improved through control of cycle time in Air-vent SBR process and decreasing SRT (BOD: 1.8%, COD: 54.5%, SS: 4.3%, T-N; 0.8% and T-P: 7.7%). This research suggests that result of this research can be utilized as a retrofit method to improve the effluent overall treatment efficiency of the MWTP and the RCSTP which have similar operation process.

The Runoff Characteristics of Non-point Pollution Sources in Industrial Complex(II): Focusing on the Outflow Characteristics of the C Industrial Complex by Rainfall Event (산업단지 비점오염원의 유출특성(II): C산업단지의 강우사상별 유출특성을 중심으로)

  • Woo, Jae-Suk;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.1
    • /
    • pp.41-47
    • /
    • 2022
  • In this study, rainfall water outlet water quality monitoring was performed on the C industrial complex to evaluate the characteristics of non-point pollutant runoff from the industrial complex during rainfall and to use it as basic data for calculating the load and unit of non-point pollutant. As a result of calculating EMC according to the outflow amount by rainfall event, the 1st rainfall showed EMCs ranges of BOD, CODMn, SS, T-N, and T-P of 1.32~48.76, 3.32~43.75, 2.89~199.43, 2.76~8.93, 0.08~068, and the 2nd rainfall was 0.5~2.9, 2.71~7.13, 2.82~174.94, 1.33~4.03, 0.01~1.28 mg/L, respectively. As a result of calculating the ratio of cumulative outflow and cumulative pollution load, most of the pollution load was less than the rainfall outflow, but over time, the initial washing phenomenon occurred as the ratio of cumulative rainfall outflow and cumulative pollution load increased to more than 1.