• 제목/요약/키워드: T2 Measurement

검색결과 2,008건 처리시간 0.029초

Temperature dependence of photocurrent spectra for $AgInS_2$ epilayers grown by hot wall epitaxy

  • Baek, Seung-Nam;Hong, Kwang-Joon
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.123-124
    • /
    • 2007
  • A silver indium sulfide ($AgInS_2$) epilayer was grown by the hot wall epitaxy method, which has not been reported in the liteniture. The grown $AgInS_2$ epilayer has found to be a chalcopyrite structure and evaluated to be high quality crystal. From the photocurrent measurement in the temperature range from 30 K to 300 K, the two peaks of A and B were only observed, whereas the three peaks of A, B, and C were seen in the PC spectrum of 10 K. These peaks are ascribed to the band-to-band transition. The valence band splitting of $AgInS_2$ was investigated by means of the photocurrent measurement. The temperature dependence of the energy band gap of the $AgInS_2$ obtained from the photocurrent spectrum was well described by the Varshni's relation, $E_g(T)=\;E_g(0)\;eV-(7.78\;{\times}\;10^{-4}\;eV/K)T^2/(T\;+\;116\;K\;K)$. Also, Eg(0) is the energy band gap at 0 K, which is estimated to be 2.036 eV at the valence band state A and 2.186 eV at the valence band state B.

  • PDF

초음파 위배출 측정과 한의설문 간의 상관성 분석 (Correlation Analysis between Gastric Emptying Measurement by Ultrasonography and Korean Medical Questionnaires)

  • 조수호;이재홍;고석재;김진성;박재우
    • 대한한방내과학회지
    • /
    • 제39권4호
    • /
    • pp.570-591
    • /
    • 2018
  • Objective: This study was designed to investigate the correlation between gastric emptying measurement by ultrasonography and the findings of various questionnaires of functional dyspepsia (FD) or in Korean medicine to explore the possibility of quantification of questionnaires. Methods: Eighty-eight patients (44 patients with FD and 44 healthy controls) were recruited from October 2016 to November 2017. Gastric emptying half-time (T1/2) was measured by ultrasonography at fasting, and at 0, 15, 30, 45, 60, 90, and 120 min after meals (apple juice, 500 ml, 224 kcal). The average half-time (average T1/2) was calculated by averaging all measured half-times. A visual analogue scale (VAS), food retention questionnaire (FRQ), damum questionnaire (DQ), cold and heat questionnaire (CHQ), deficiency and excess questionnaire (DEQ), spleen-qi deficiency questionnaire (SQDQ), Nepean dyspepsia index-Korean version (NDI-K), and quality of life of NDI (NDI-QoL) were filled out by all participants. Correlation between the average T1/2 and questionnaires were analyzed for 79 patients (37 patients with FD and 42 healthy controls) after excluding missing and erroneous data. Results: The FRQ, DEQ, SQDQ, NDI-K, and NDI-QoL scores, especially for some gastrointestinal symptoms and general weakness-related symptoms, showed statistically significant correlations with average T1/2. Conclusions: Our results suggest that gastric emptying measurement by ultrasonography may be a quantitative substitute method for some Korean medical questionnaires or for some dyspepsia-related and deficiency-related items among them. However, further studies using various measurements of gastric emptying will be needed.

TRY 방법론에 의한 표준일사량데이터 평가 (Evaluation of Typical Solar Radiation Data by the TRY Methodology)

  • 유호천;이관호;김경률;박소희
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.23-28
    • /
    • 2007
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Clear data should be prepared to apply solar energy to architecture aggressively and properly. This study used FS statistical analysis data regarding average daily solar radiation of Seoul observed over 20 years to find out standard year and standard daily solar radiation. This study also aims to compare and evaluate an appropriate method of selecting a standard year which is too close to measurement value through comparison and analysis with daily solar radiation acquired by applying overseas researchers' suggesting weight factor. As a result, the data nearest to measurement value of daily solar radiation was UK CIBSE TRY(TYPE 2) displaying 0.100in t-statistic index. For UK CIBSE TRY(TYPE 2), weight factor was applied to three climatic elements except relative humidity. TYPE 1 and TYPE 3 recorded 0.343 and 0.367, respectively, showing higher record of t-statistic than TYPE 2. TYPE 1 was calculated through FS statistical value of single data about daily solar radiation with other climatic elements excluded. For TYPE 3, relative humidity was added to TYPE 2. In particular, since TYPE 2 was closer to the measurement value compared to the others, it is necessary to consider relationship with other climate elements if other climate elements are added.

모니터링위원회를 통한 작업환경 개선 활성화 방안 (Study on the Promoting the Improvement of Work Environment by the Monitoring Committee for Work Environment Measurement)

  • 황규석
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.158-165
    • /
    • 2018
  • Objectives: We analyzed the problems that work environment measurement results don't lead to workplace improvement in the Work Environment Measurement System to propose an alternative. Methods: We reviewed reports and articles written by the Korea Occupational Safety and Health Agency and academic circles to identify the problems in the current Work Environment Measurement System and suggest an alternative. Results: One of the reasons that the Work Environment Measurement has not resulted in workplace improvement is that there were no proper regulating systems for managing the workplace improvement plans or improvement results. Moreover, there are not enough professional manpower in ministry of labor to evaluate the improvement plans and results from the Work Environment Measurement. Therefore, all of the workplace whose Work Environment Measurement results exceed the occupational exposure limit (OEL) should be managed by regional ministry of labor, and outside experts and new system for verifying improvement are needed. Conclusions: To accomplish the purpose of Work Environment Measurement, it is necessary to improve the work environment according to the results of Work Environment Measure. For this, it is necessary for the government to manage the fulfillment of workplace improvement plans and for measurement agencies to secure expertise.

투과특성의 on-line 측정을 위한 투과장치 (Permeation Apparatus for on-line Measurement of the Permeation Characteristics through Dense Polymeric Membranes)

  • 염충균;김범식;김철웅;김광주;이정민
    • 멤브레인
    • /
    • 제8권2호
    • /
    • pp.86-93
    • /
    • 1998
  • 비다공성막을 통한 투과성분의 투과속도와 투과 조성을 on-line방식으로 측정할수 있는 장치를 개발하였다. 가교폴리비닐알콜막을 통한 물의 투과증발실험을 행하여 이 장치의 효용성을 확인하였다. 투과증발실험에서 투과가 정상상태에 도달하는데 15분미만의 시간이 걸렸으며 측정을 20분이내에 마칠 수가 있었다. 또한 측정된 투과속도 정확성과 신뢰도를 확인하기 위해서 종래의 방법대로 액체질소에 의해 투과물을 일정시간 응축시켜 투과속도를 동시에 측정하여 이를 장치의 record에 표시된 투과속도와 비교한 결과 그 오차가 $\pm$2% 이내로 일치하였다. 측정된 시간에 따른 투과속도 곡선으로 부터 3가지 종류의 확산계수 $D_{slope}, D_{1/2}, D_t$를 구하였고 이들이 문헌치와 비교한 결과 비교적 일치함을 보였다. 또한 on-line 방식으로 모든 측정이 이루어지므로 종래 방법, 즉 투과물 응축, 가열, 무게측정과정 등에서 발생할 수 있는 실험오차를 줄일수 있기 때문에 정확한 투과특성을 얻을 수가 있다. 본 연구에서 개발한 투과 장치를 사용하여 액체상태의 feed 투과를 효과적으로 분석할 수 있음을 확인하였다.

  • PDF

RADIATION SAFETY STUDIES AT TOHOKU UNIVERSITY CYRIC

  • Yamadera M. Baba A.;Miura T.;Aoki T.;Hagiwara M.;Kawata N.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.231-236
    • /
    • 2001
  • A brief introduction is presented on the radiation safety studies at Tohoku University Cyclotron & Radioisotope Center. Studies on two subject are described; (1) measurement of the thick target neutron yield and radioisotope production / activation cross section for ten's of MeV neutrons and ions using K=110 Tohoku University cyclotron to provide basicdata for accelerator shielding, and (2) development of techniques for high sensitive radiation detection and profile measurement using an Imaging Plate which is a high sensitive two-dimensional radiation sensor. Application of the Imaging Plate techniques to localization of very weak radioactivity and to neutron profile measurement is described.

  • PDF

잡음평형도와 측정회로에 관한 연구 (A Study on the Degree of Line Balance to Noise and its Measurement Circuits)

  • 여상근;김정태
    • 정보통신설비학회논문지
    • /
    • 제9권2호
    • /
    • pp.35-41
    • /
    • 2010
  • The balance coefficients between telecommunication lines are specified in the technical standard and the power induction computation method varies in the order of 100 times in magnitude according to the amount of impedance. The results of actual balance measurements, differing from time to time with the measurement circuit or increasing proportionally as the induction voltage increases, appeared as a measurement error because of not using the standard measurement circuit. This article investigates such errors and proposes the use of a standard balance measurement circuit and a measurement device impedance under the domestic notification standard and the ITU-T international standard.

  • PDF

여름철 단일수목의 음이온 발생에 관한 평가 (Assessment of Anion Generation on the Isolated Trees at Summer)

  • 김정호;서유환;주창훈;윤용한
    • 한국조경학회지
    • /
    • 제42권4호
    • /
    • pp.1-9
    • /
    • 2014
  • 본 연구는 단일수목 중심으로 측정지점의 변화를 통해 위치에 따른 음이온 변화를 분석하고자 하였다. 연구대상지는 건국대학교 글로컬캠퍼스 내에 위치한 느티나무를 선정하여 하지를 기준으로 총 3일간 측정을 실시하였으며, 그림자가 형성되는 반대 방향에 위치한 $T_a$지점과 수목의 중앙에 위치시킨 $T_b$지점, 그림자 중앙에 위치시킨 $T_c$지점, 그림자 끝 지점에 위치시킨 $T_d$지점으로 총 4개소로 구분하여 측정하였다. 측정일 간 평균기온은 $T_a$지점이 $28.4^{\circ}C$로 가장 높았으며, 그림자 중앙에 위치시킨 $T_c$지점이 가장 낮은 $27.9^{\circ}C$로 나타났다. 상대습도는 기온이 가장 높았던 $T_a$지점에서 가장 낮은 42.5%를 기록하였다. 일사량의 경우 $T_a$지점에서 $1,024.6W/m^2$로 가장 높았으며, $T_d$지점($701.48W/m^2$) > $T_c$지점($215.63W/m^2$) > $T_b$지점($227.75W/m^2$) 순으로 조사되었고, 음이온 측정결과, $T_a$지점에서 가장 높은 $654ea/cm^3$로 측정되었으며, $T_d$지점 > $T_c$지점 > $T_b$지점 순으로 각각 $639.4ea/cm^3$, $615.3ea/cm^3$, $612.3ea/cm^3$로 나타났다. 상관성 분석결과, 음이온은 세 가지 기상요소, 기온, 일사량, 상대습도와 상관성이 검증되었다. 기온과 일사량의 경우 정의 상관성을 보이고, 각각 .687과 .332의 상관계수를 보였으며, 유의확률은 .000, .037로 나타났다. 또한 상대습도는 부의 상관관계로 상관계수와 유의확률이 각각 -.557, .000으로 분석되었다.

반절연성 GaAs에서 열자극 전류에 관한 연구 (A study on thermally stimulatede current in semi-insulating GaAs)

  • 배인호;김기홍;김인수;최현태;이철욱;이정열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권5호
    • /
    • pp.383-388
    • /
    • 1994
  • Deep levels in semi-insulating GaAs were observed by thermally stimulated current(TSC) measurement In the temperature ranges of 100-300K Tl(E$\_$c/-0.18eV), T2(E$\_$c/-0.20eV), T3(E$\_$c/-0.31eV), T4(E$\_$c/-0.40eV), and T5(E$\_$c/-O.43eV) traps have been observed. The TI, T2, and T5 traps seem to be related to the V$\_$As/, V$\_$Ga/-complex, and As$\_$Ga/$\^$++/ respectively. T4 trap is considered with respect to V$\_$Ga/-V$\_$As/ complex.

  • PDF

함정 자기신호 측정용 3-축 디지털 자기센서 설계 및 제작에 관한 연구 (Design and Fabrication of Digital 3-axis Magnetometer for Magnetic Signal from Warship)

  • 김은애;손대락
    • 한국자기학회지
    • /
    • 제24권4호
    • /
    • pp.123-127
    • /
    • 2014
  • 본 연구에서는 함정을 자기소거시키는 과정에서 함정에 의한 자기장을 측정하기위한 3-축의 flux-gate 마그네토미터를 설계 제작하였다. 설계에서 고려한 사항은 자기장측정지점과 자기장 데이터를 수집하는 장치 사이의 거리가 수백미터로 멀기 때문에 입력전압의 변동이 커도 동작이 되게 전압 범위가 16~36 V까지 가능한 DC/DC 변환기를 사용하였고, 데이터의 전송은 자기장 측정값을 디지털로 변환 시킨 후 RS422통신으로 전송하게 하였다. 또한 함정을 자기소거 하는 과정에서 발생하는 ${\pm}1mT$ 자기장하에서도 0점의 변화가 ${\pm}2nT$ 이하가 되게 피측정자기장의 보상은 ${\pm}1mT$, 측정범위는 ${\pm}0.1mT$가 되게 제작을 하였다. 또한 수심 30 m에서도 동작되어야하는 조건을 고려하여 6기압 하에서 센서가 수밀이 되고 정상 작동이 되는 것을 확인 하였다. 마그네토미터의 일반특성으로는 선형도가 측정범위 ${\pm}0.1mT$에서 0.01 % 이상 이였고 센서의 노이즈는 1 Hz에서 $30pT/\sqrt{Hz}$이였다.