• Title/Summary/Keyword: T2 Measurement

Search Result 2,003, Processing Time 0.034 seconds

Differences in Blood Pressure among Adults in the Community according to Blood Pressure Measurement Time and Age (지역사회 성인의 혈압측정횟수 및 연령에 따른 혈압의 차이)

  • Park, Kyung-Yeon
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.4
    • /
    • pp.275-282
    • /
    • 2019
  • Purpose: This study aimed to identify the differences in blood pressure among adults in the community according to age and time of the blood pressure measurement. Methods: This was a secondary analysis study, using data from a 2015 community health survey, conducted by the Korea Centers for Disease Control and Prevention. The data of three-time-measured blood pressure were collected from 337 subjects, 25, 35, 45, 55, 65, 75 years old, which are median ages by each age group. Results: The primary systolic pressure was significantly higher than the secondary systolic pressure (t= 3.46, p= .001) and the tertiary systolic pressure (t= 4.83, p= .001). The secondary systolic pressure was higher than the tertiary measurement (t= 2.05, p= .041). There was no significant difference between the three-time-measured values for diastolic pressure. There was a significant interaction between measurement times and age in the systoic blood pressure readings (F= 1.95, p= .036). However, there was no significant interaction between measurement times and age in the diastolic blood pressure readings (F= 1.03, p= .418). Conclusion: The findings suggest that attention must be paid to the use of blood pressure values in studies or one-time-measured clinical blood pressure values. In particular, the differences in systolic pressure readings taken at different times in the older age groups were significant. Therefore, it is more important to carefully assess blood pressure in adults over the age of 45 compared to other age groups.

A Study on Effective Management for Measurement System (측정시스템의 효율적 운영에 관한 실증적 연구 - 중소제조기업(中小製造企業)을 중심(中心)으로 -)

  • Yoo, Hyun-Jong;Jun, Hyun-Jung;Yoo, Jae-Kwon
    • Journal of Industrial Convergence
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2003
  • "All things possibly could be measured.", measurement is a essential part in all kinds of industry, especially in manufacturing. Korean Industrial Standard has been established and announced in September, 1961. Measurement has been emphasized. But until now, measurement hasn't been located to the core of manufacturing in domestic. So, this study suggests improvement guide line for the multilateral problems of measurement system based on the investigation of 146 small and medium-sized enterprises in April, 2002.

  • PDF

Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment (High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

Characteristics of Nonpoint Source Pollutant Loads from Forest watershed with Various Water Quality Sampling Frequencies (수질샘플빈도에 따른 산림유역의 비점원오염부하특성)

  • Shin, Min-Hwan;Shi, Yong-Chul;Heo, Sung-Gu;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2008
  • A monsoon season monitoring data from June to September, 2005 of a small forested watershed located at the upstream of the North Han River system in Korea was conducted to analyze the flow variations, the NPS pollutant concentrations, and the pollution load characteristics with respect to sampling frequencies. During the 4-month period, 1,423 mm or 79.2% of annual rainfall(1,797 mm) were occurred and more than 77%, 54% and 68% of annual T-N, $NO_3$-N and T-P loads discharged. Flow rate was continuously measured with automatic velocity and water level meters and 58 water quality samples were taken and analyzed. It was analyzed that the flow volume by random measurement varied very widely and ranged from 79% to 218% of that of continuous measurement. It was recommended that flow measurement of small forested watersheds should be continuously measured with automated flow meters to precisely measure flow rates. Flow-weighted mean concentrations of T-N, $NO_3$-N and T-P during the period were 2.114 mg/L, 0.836 mg/L, and 0.136 mg/L, respectively. T-N, $NO_3$-N and T-P loads were sensitive to the number of samples. And it was analyzed that in order to measure the pollution load within the error of 10% to the true load, the rate of sampling frequency should be higher than 89.7% of the sample numbers that were required to compute the true pollution load. If it is compared to selected foreign research results, about 10 water samples for each rainfall event were needed to compute the pollution load within 10% error. It is unlikely in Korea and recommended that thorough NPS pollution monitoring studies are required to develop the standard monitoring procedures for reliable NPS pollution quantification.

Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.

A Case Study on Explosives Demolition of Central Library (중앙 도서관 발파해체 시공사례)

  • Park, Keun-Soon;Kim, Sang-Hoon
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.77-91
    • /
    • 2008
  • According as demand for superannuated building increases recently, much researches about demolition method of construction are going on. This case study executed to center library building located in Dankook University. Explosives demolition method applied Progressive Collapse. Explosives demolition main blasting floors are 2, 4floor, assistance blasting floor is 1 floor. In the nearest distance (150 m), Vibration measurement result were 0.0302 cm/sec (PPV). Change was not in measurement value is crack gauge which install beforehand.

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Approach for Microwave Frequency Measurement Based on a Single Photonic Chip Combined with a Phase Modulator and Microring Resonator

  • Zhang, Jiahong;Zhu, Chuyi;Yang, Xiumei;Li, Yingna;Zhao, Zhengang;Li, Chuan
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.576-581
    • /
    • 2018
  • A new approach for identification of a microwave frequency using an integrated optical waveguide chip, combined with a phase modulator (PM) and two microring resonators (MRRs), is proposed, theoretically deduced, and verified. By wavelength tuning to set the PM under the condition of a double side band (DSB), the measurement range can be started from the dc component, and the measurement range and response slope can be adjusted by designing the radius and transmission coefficient of the MRR. Simulations reveal that the amplitude comparison function (ACF) has a monotonic relationship from dc to 32.5 GHz, with a response slope of 5.15 dB under conditions of DSB modulation, when the radius values, transmission coefficients, and the loss factors are designed respectively as $R_1=400{\mu}m$, $R_2=600{\mu}m$, $t_1=t_2=0.63$, and ${\gamma}_1={\gamma}_2=0.66$. Theoretical calculations and simulation results both indicate that this new approach has the potential to be used for measuring microwave frequencies, with the advantages of compact structure and superior reconfigurability.

The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times (상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구)

  • Kim In-Sung;Lee Young-Ju;Kim Ju-Hyun;Sujit Dutta;Kim Suk-Kyung;Kim Tae-Jeong;Kang Duk-Sik;Chang Yong-Min
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2006
  • To evaluate the T1, T2 magnetic relaxation properties of water molecule according to molecular weight of paramagnetic complex. 4-aminomethyicyclohexane carboxylic acid (0.63 g, 4 mmol) was mixed with the suspension solution of DMF (15 ml) and DTPA-bis-anhydride (0.71 g, 2 mmol) to synthesize the ligand. The ligand was then mixed with $Gd_2O_3$ (0.18 g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1 mM and then the relaxation times were measured at 1.57 (64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG (Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. In case of inversion recovery sequence, total 35 images with different inversion time(T1)s ranging from 50 msec to 1,750 msec. To estimate the relaxation times, the signal intensity of each sample was measured using region of Interest (ROI) and then fitted by non-linear least square method to yield T1, T2 relaxation times and also R1 and R2. Compared to T1=($205.1{\pm}2.57$) msec and T2=($209.4{\pm}4.28$) msec of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, T1 and T2 values of new paramagnetic complexes were reduced along with their molecular weight. That is, T1 value was ranged from $(96.35{\pm}2.04)\;to\;(79.38{\pm}1.55)$ msec and T2 value was ranged from $(91.02{\pm}2.08)\;to\;(76.66{\pm}1.84)$ msec. Among new paramagnetic complexes, there is a tendency that the R1 and R2 increase as the molecular weight is increases. As molecular weight of paramagnetic complex increases, T1 and T2 relaxation times reduce and thus the increase of relaxivity (R1 and R2) Is proportional to molecular weight.

  • PDF

Design and Characterization of Low-noise Dewar for High-sensitivity SQUID Operation (고감도 SQUID 냉각을 위한 저잡음 듀아의 설계 및 특성 조사)

  • Yu, K.K.;Lee, Y.H.;Kim, K.;Kwon, H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.152-157
    • /
    • 2010
  • We have fabricated the low noise liquid helium(LHe) dewar with a different shape of thermal shield to apply the 64-channel SQUID(Superconducting Quantum Interference Device) gradiometer. The first shape of thermal shield was made of an aluminum plate with a wide width of 100 mm slit and the other shape was modified with a narrow width of 20 mm slit. The two types of dewars were estimated by comparing the thermal noise and the signal-to-noise ratio(SNR) of magnetocardiography(MCG) using the $1^{st}$ order SQUID gradiometer system cooled each dewar. The white noise was different as a point of the dewar. The noise was increased as close as the edge of dewar, and also increased at the thermal shield with the more wide width slit. The white noise of the dewar with thermal shield of 100 mm slit was 6.5 fT/$Hz^{1/2}$ at the center of dewar and 25 fT/$Hz^{1/2}$ at the edge, and the white noise of the other one was 3.5 - 7 fT/$Hz^{1/2}$. We measured the MCG using 64-channel SQUID gradiometer cooled at each LHe dewar and compared the SNR of MCG signal. The SNR was improved of 10 times at the LHe dewar with a modified thermal shield.