• Title/Summary/Keyword: T2 강조영상

Search Result 267, Processing Time 0.025 seconds

The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D FSPGR T1 Technique and Fat Suppressed Isotropic 3D FSE T1 Technique when Examining MRI of Patient with Triangular Fibrocartilage Complex (TFCC) Tear (삼각 섬유성 연골(TFCC) 손상 환자의 자기공명영상 검사 시 Fat Suppressed 3D FSPGR T1 강조 기법에 대한 Fat Suppressed Isotropic 3D FSE T1 강조 기법의 비교 분석 및 유용성에 관한 평가)

  • Kang, Sung-Jin;Cho, Yong-Keun;Lee, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.105-114
    • /
    • 2016
  • In this study, For assessment of triangular fibrocartilage complex (TFCC) injury, we acquired images by fat suppressed 3D fast spoiled gradient recalled T1 and fat suppressed Isotropic 3D fast spin echo T1 techniques. For quantitative evaluation, measured signal to noise ratio and contrast to noise ratio and verified statistical significance between two imaging techniques by Mann-Whitney U verification. And for qualitative evaluation, marked 4-grade scoring (0: non diagnostic, 1: poor, 2: adequate, 3: good) on shape of TFCC, artifacts by partial volumes, description of the lesions by two radiologist, verified coincidence between 2 observer using Kappa-value verification. We used 3.0 Tesla MR equipment and 8-channel RF coil for imaging acquisition. As quantitative evaluation results, signal to noise ratio and contrast to noise ratio value of Isotropic 3D fast spin echo T1 technique is higher in every image sections, also between two imaging techniques by Mann-Whitney U verification was statistically significant (p < 0.05). As qualitative results, observer 1, 2 marked a higher grade on Isotropic 3D FSE T1 technique, coincidence verification of evaluation results between two observers by Kappa-value verification was statistically significant (p < 0.05). As a result, during MRI examination on TFCC injury, fat suppressed Isotropic 3D fast spin echo T1 technique is considered offering more useful information about abnormal lesion of TFCC.

MR Findings of Hypoxic Brain Damage: Relation to Time Elapse and Prognosis of Patients (저산소성 뇌손상의 자기공명영상 소견: 유병기간 및 예후와의 연관성)

  • Suh, Kyung-Jin;Kang, Chae-Hoon;Yoo, Dong-Soo;Kim, Sang-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.8-15
    • /
    • 2006
  • Purpose : To describe MR imaging features of hypoxic brain damage in relation to time elapse and prognosis of patients. Materials and methods : We reviewed 19 MR studies of 18 patients with hypoxic brain damage. MR imaging studies were performed between 1 to 20 days after the hypoxic insults (mean 8.6 days). MR images were analyzed with regard to the locations of abnormal signal intensities, the presence of brain edema. And imaging findings were correlated with the time elapse after the insults and the prognosis of patients. Results : On 19 cases of MR studies, abnormal high intensities on T2-weighted images were found in the basal ganglia (15, 78.9%), cerebral cortex (13, 68.4%), white matter (9, 47.4%), thalamus (6, 31.6%), cerebellum (4, 21.1%) and brainstem (1, 5.3%), respectively. Cerebral cortical involvement was typically bilateral and diffuse, but sometimes limited to the parieto-occipital area. The brainstem and cerebellar involvement was rare and in all cases, cerebral cortical lesions accompanied. Most of the white matter lesions were accompanied with cortical and deep gray matter lesions and found in subacute period(>6 days). The cortical high signal intensity lesions on T1-weighted image were found mostly in subacute stage, but in some cases involvement was also found in acute stage ($\leq$ 6 days). The cortical edema is found on 11 cases in acute and subacute stages. In cases of recovered consciousness, cortical involvement and edema on MR were rare. Conclusion : MR findings of hypoxic brain damage were various, but diffuse bilateral involvement of cortex and/or deep gray matter was found in most of the cases. White matter involvement was rarely found in acute stage and usually found in subacute stage. In cases of good pronosis, cortical involvement and edema were rare.

  • PDF

In Vivo and In Vitro Studies of the Steady State Free Precession-Diffusion-Weighted MR Imagings on Low b-value : Validation and Application to Bone Marrow Pathology

  • Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Purpose : The purpose of this study was a phantom study to measure the diffusion properties of water molecules by steady-state free precession diffusion-weighted imaging (SSFP- DWI) with a low b-value and to determine if this sequence might be useful for application to the evaluation of bone marrow pathology. Materials and methods : 1. The phantom study: A phantom study using two diffusion weighted sequences for the evaluation of the diffusion coefficient was performed. Three water-containing cylinders at different temperatures were designed: phantom A was $3^{\circ}C$, B was $23^{\circ}C$ and C was $63^{\circ}C$. Both SSFP and echo planar imaging (EPI) sequences (b-value: $1000s/mm^2$) were performed for comparison of the diffusion properties. The Signal to noise ratios (SNR) and apparent diffusion coefficient (ADC) values of the three phantoms using each diffusion-weighted sequence were assessed. 2. The Clinical study: SSFP-DWI was performed in 28 patients [sacral insufficiency fractures (10), osteoporotic lumbar compression fractures (10), malignant compression fractures (8)]. To measure the ADC maps, a diffusion-weighted single shot stimulated echo-acquisition mode sequence ($650s/mm^2$) was obtained using the same 1.5-T MR imager Results : For the phantom study, the signal intensity on the SSFP as well as the classic EPI-based DWI was decreased as the temperature increased in phantom A to C. The ADC values of the phantoms on EPI-DWI were $0.13{\times}10^{-3}mm^2/s$ in phantom A, $0.22{\times}10^{-3}mm^2/s$ in B and $0.37{\times}10^{-3}mm^2/s$. in C. The SSFP can be regarded as a DWI sequence in view of the series of signal decreases. Conclusion : Bone marrow pathologies with different diffusion coefficients were evaluated by SSFP-DWI. All benign fractures were hypointense compared to the adjacent normal bone marrow where as the malignant fractures were hyperintense compared to the adjacent normal bone marrow.

  • PDF

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

Quantitative Evaluation of Optimized Fat-Suppression Techniques for T2 Weighted Abdominal MR Imaging : Comparison of TSE-SPIR and GE-PROSET (T2 강조 복부자기공명영상에 대한 최적의 지방소거 기법의 정량적 평가 : TSE-SPIR 와 GE-PROSET 비교)

  • Goo, Eun-Hoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4962-4969
    • /
    • 2013
  • The purpose of this experiment is to evaluate of optimized FS techniques for T2 weighted abdominal MRI compared of TSE-SPIR fat suppression and GE-PROSET fat suppression. All MR examinations were performed on a 1.5 T(Philips, Medical System, Achieva) scanner using 16 channel mult-coils. All images were performed in the axial plane using TSE-SPIR and GE-PROSET. The mean SNRs of the retroperitoneal and mesenteric fat for TSE-SPIR and GE-PROSET were 31.50, 4.15 and 32.39, 7.03. The mean CNRs of the bowel and retroperitoneal, mesenteric fat for TSE-SPIR and GE-PROSET were 52.69, 74.54 and 26.12, 68.78). The delineation of bowel wall margins with TSE-SPIR(2.4) and GE-PROSET(1.8) were significantly improved using TSE-SPIR. The delineation of pancreas wall with TSE-SPIR(1.90), GE-PROSET(2.80) were significantly improved using GE-PROSET. In conclusion, TSE-SPIR fat suppression was superior to GE-PROSET fat suppression in T2 WI FS abdominal MRI.

A Case Report of Axillary Hibernoma: US, CT, MR, and Histopathologic Findings (액와부 갈색지방종의 증례 보고: 초음파, 컴퓨터단층촬영, 자기공명영상, 병리 소견)

  • Ji Yeon Park;Seong Yoon Yi;Ji Young Lee;Tae Jung Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.439-443
    • /
    • 2022
  • Hibernoma is a rare benign tumor of brown adipose tissue. Herein, we report a case of axillary hibernoma in a 53-year-old female and discuss the various radiologic findings. The US revealed a 4.5-cm well-defined oval heterogenous hyperechoic mass in the right axilla with anterior displacement of the axillary vessels. Non-enhanced chest CT showed a 5.0-cm well defined, oval, and low-attenuated mass. MRI demonstrated a 5.5-cm mass with heterogeneous intermediate-to-high signal intensity on T1-and T2-weighted images and irregular enhancement at the peripheral portion. The patient underwent an US-guided core needle biopsy and the final diagnosis was hibernoma.

SCHWANNOMA OF THE SUBLINGUAL GLAND : REPORT OF A CASE (설하선에 발생된 신경초종)

  • Lee Eun-Sook;Choi Soon-Chul;Park Tae-Won;You Deong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.461-466
    • /
    • 1994
  • 신경초종은 신경초에서 발생되는 성장이 느린 양성 종양으로 단발성이며 드물다. 이 종양은 말초 신경,자율 신경,뇌신경의 Schwann세포에서 발생된다. 두경부 영역의 두개외 신경성 종양은 드물며 특히 타액선에서 발생되는 예는 드물다. 저자들은 20세 여자 환자에서 아래와 같은 소견을 나타내는 신경초종을 경험하였기에 보고하는 바이다. 1.주소는 좌측 악하선 부위의 종창이었으며 촉진시 3×4㎝의 단단한 종괴가 만져졌으나 동통이나 림프절병증은 없었다. 2. 일반방사선사진에서 종괴와 관련된 골변화는 없었으나 초음파 영상에서는 불균질한 반사 양상을 보이는 종괴가 좌측 악하선 영역에서 관찰되었다. 3. 자기공명영상으로 병소의 정확한 위치를 확인할 수 있었다. 병소의 경계는 명확하였으나 신호 강도는 균일하지 않았으며 T1 강조 영상에서는 근육과 유사한 신호 강도를 보였으나 T2 강조 영상에서는 근육보다 높은 신호 강도를 나타냈다. 4. 조직 병리학적으로 Antoni type B 부위보다는 A 부위가 지배적이었으며 Verocay body도 나타났다. 종양 세포는 anti-S-100 염색에 양성으로 반응하였다.

  • PDF

Dynamic Characteristic Change of the Cerebral Blood Volume in Cats Using Perfusion MR Imaging (MR 관류영상을 이용한 고양이 대뇌 혈류량의 동적특성 변화)

  • 박병래;김학진;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.243-251
    • /
    • 2004
  • This study was to quantitative analysis compare to dynamic characteristic change of the regional cerebral blood volume (rCBV) after development of cerebral fat embolism in cats using perfusion MR Imaging. Forty-four adult rats were used. Triolein (n = 15), oleic acid (n = 9) and linoleic acid (n = 11) were injected into the internal carotid artery using microcatheter through the transfemoral approach. Polyvinyl alcohol (Ivalon) (n = 9) was injected as a control group. Perfusion MR images were obtained at 30 minutes and 2 hours after embolization, based on T2 and diffusion-weighted images. The data was time-to-signal intensity curve and ΔR$_2$* curve were obtained continuously with the aid of home-maid image proc in.leased significantly at 2 hours compared with those of 30 minutes (P<0.005). In conclusion, cerebral blood flow decreased in cerebral fat embolism immediately after embolization and recovered remarkably in time course. It is thought that clinically informations to dynamic characteristic change of the cerebral hemodynamics to the early finding in cerebral infarction by DWI and PWI

확산텐서영상에서 확산경사자장의 방향수에 따른 FA값 및 FA의 표준편차와의 상관 관계

  • 이영주;황문정;배성진;장용민;우성구;서수지
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.33-33
    • /
    • 2003
  • 목적: 확산텐서영상 획득시 확산경사자장의 방향수와 FA값, 그리고 FA값의 표준편차와의 상관관계를 조사해 보고자 하였다. 대상 및 방법: 3T MR scanner에서 정상성인 10명(남자 5명, 여자 5명)을 대상으로 걸어주는 확산강조 경사자장의 수(N = 6, 11, 23, 35, 47)를 증가시키며 확산텐서영상을 획득하였다. 획득된 영상들로부터 FA map을 만들고 주요 뇌구조물(frontal GM, putamen, posterior limb of internal capsule, thalamus 등)에 관심영역을 설정하여 FA값을 측정하였으며 그 FA값의 표준편차(sd) 를 계산하였다. 이때 사용한 펄스열은 Stejskal-Tanner type의 확산강조 경사자장이 포함된 single-shot SE EPI를 사용하였으며 영상획득시 사용한 피라미터는 다음과 같다. TR/TE=8000ms/71ms, Thickness/spacing=5/2mm, FOV=240mm, Matrix=$128{\times}128$, NEX= 1, b value=1000s/$\textrm{mm}^2$.

  • PDF