• Title/Summary/Keyword: T1 relaxation time

Search Result 140, Processing Time 0.033 seconds

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

A Comparison Study of Signal Intensity of Gadolinium Contrast Media on Fast Spin echo and Ultra Short Time Echo Pulse Sequence at 3T MRI-Phantom Study (3T 자기공명영상 Fast Spin Echo (FSE)와 Ultra Short Time Echo (UTE) 펄스 시퀀스에서 가돌리늄 조영제 희석농도와 신호강도 비교 -팬텀 연구)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2015
  • The information of contrast media concentration on target organ is very important to get reduce the side effect and high contrast imaging. We investigated alternation of signal intensity as a function of the modality of Gd-based contrast media on spin echo and ultra short time echo (UTE) of T1 effective pulse sequence at 3T MRI unit. Gadoxetic acid, which is a MRI T1 contrast medium, was used to manufacture an agarose phantom diluted in various molarities, and sterile water and agarose 2% were used as the buffer solution for the dilution. The gold standard T1 calculation was based on coronal single section imaging of the phantom mid-point with 2D Inversion recovery spine-echo pulse sequence MR imaging for testing of phantom accuracy. The 1-2mmol/L and 7mmol/L was shown the maximum signal intensity on spin echo and UTE respectively. We confirm the difference of contrast media concentration which was shown the maximum signal intensity depending on the T1 effective pulse sequence.

MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent (조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.73-82
    • /
    • 1998
  • Purpose : A precise NMR technique for measuring the rate of water exchange and cell membrane permeability across the hepatocyte membrane using liver-specific MR contrast agent is described. Materials and Methods : The rat hepatocytes isolated by perfusion of the livers were used for the NMR measurements. All experiments were performed on an IBM field cycling relaxometer operating from 0.02MHz to 60 MHz proton Larmor frequency. spin-echo pulse sequence was empolyed to measure spin-lattice relaxation time, T1. The continuous distribution analysis of water proton T1 data from rat hepatocytes containing low concentrations of the liver specific contrast agent, Gd-EOB-DTPA, modeled by a general two compartment exchange model. Results : The mean residence time of water molecule inside the hepatocyte was approximately 250 msec. The lower limit for the permeability of the hepatocyte membrane was $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$. The CONTIN analysis, which seeks the natural distribution of relaxation times, reveals direct evidence of the effect of diffusive exchange. the diffusive water exchange is not small in the intracellular space in the case of hepatocytes. Conclusions : Gd-EOB-DTPA, when combined with continuous distribution analysis, provides a robust method to study water exchange and membrane permeability in hepatocytes. Water exchange in hepatocyte is much slower thatn that in red blood cells. Therefore, tissue-specific contrast agent may be used as a functional agent to give physiological information such as cell membrane permeability.

  • PDF

An Effect of Guided Imagery on Pain (통증에 대한 지시적 심상요법의 효과 - 대학생을 중심으로 -)

  • Kim Joo-Hyun
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.5 no.1
    • /
    • pp.20-38
    • /
    • 1999
  • This study is conducted to test an effect of the guided Imagery program on artificially induced pain and to develop an effective nursing intervention for patients with pain. The subjects of this study were 37 normal female university students. The data were collected from September 1998 to December 1998. And two group non-equal quasi -experimental research with pre and post design was used in this study, The data were analyzed with the SPSS $PC^+$ program with percentage, t-test, paired t-test and ANCOVA. The results of this study were as follows : 1. There are no significant differences of systolic blood pressure between groups. 2. The experimental group showed significantly lower diastolic blood pressure than control group after treatment. 3. There are no significant differences of pulse rate between groups. 4. The experimental group showed significantly higher body temperature than control group after treatment. 5. There are no significant differences of pain intensity between groups. 6. There are no significant differences of pain sensation between groups. 7. There are no significant differences of perceived pain tolerance time between groups. 8. The experimental group showed significantly longer real pain tolerance time than control group after treatment. 9. There are no significant differences of anxiety scores between groups. 10. There are no significant differences of Self-esteem scores between groups. 11. There are no significant differences of Self-esteem scores between groups. 12. There are no significant differences of imagability scores between groups. 13. The post-experimental group showed significantly higher relaxation rate than pre -experimental group. 14. There are no significant differences of imaging depth degree between pre-experimental group and post-experimental group. From the above results, it can be concluded that 1. This guided imagery program could be recommenced as an effective nursing intervention to relieve pain. 2. A follow up study is needed to identify long-term effects.

  • PDF

Study on nuclear magnetic resonance of superionic conductor NH4HSeO4 in rotating frame

  • Choi, Jae Hun;Lim, Ae Ran
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.18 no.1
    • /
    • pp.41-46
    • /
    • 2014
  • In order to obtain information on the structural geometry of $NH_4HSeO_4$ near the phase transition temperature, the spectrum and spin-lattice relaxation time in the rotating frame $T_{1{\rho}}$ for the ammonium and hydrogen-bond protons were investigated through $^1H$ MAS NMR. $T_{1{\rho}}$ for the hydrogen-bond protons abruptly decreased at high temperature and it is associated with the change in the structural geometry in $O-H{\cdots}O$ bonds. This mobility of the hydrogen-bond protons may be the main reason for the high conductivity.

Dynamics of Poly[oxy-1,4-phenyleneoxy-2-{6-(4-(4-butylphenylazo)phenoxy)hexyloxy}terephthaloyl] and Poly[oxy-1,4-phenyleneoxy-2-{10-(4-(4-butylphenylazo)phenoxy)decyloxy}terephthaloyl] Studied by $^{13}C$ CP-MAS NMR

  • 조경규;한옥희;진정일
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.178-183
    • /
    • 1998
  • Carbon-13 CP-MAS NMR techniques were used to investigate dynamics of new combined type liquid crystalline polymers, poly[oxy-1,4-phenyleneoxy-2-{6-(4-(4-butylphenylazo)phenoxy)hexyloxy}terephthaloyl] and poly[oxy-1,4-phenyleneoxy-2-{10-(4-(4-butylphenylazo)phenoxy)decyloxy}terephthaloyl]. Noticeable mobility change of either aromatic groups or methylene groups is not detected between 25 ℃ and 82 ℃ from 13C spinlattice relaxation time in the rotating frame (T1ρ(C)) and contact time array experiments. However, line shape analysis shows the increase of mobility of methylene carbons in poly[oxy-1,4-phenyleneoxy-2-{6-(4-(4-butylphenylazo)phenoxy)hexyloxy}terephthaloyl] at higher temperature. The dynamics of side chanis does not seem to be affected in our experimental temperature range by the length of aliphatic chain which is connecting the side chain group to the main chain.

Supramolecular Micelle from Amphiphilic Mn(III)-porphyrin Derivatives as a Potential MRI Contrast Agent

  • Choi, Kwang-Mo;Lee, Do-Hyung;Jang, Woo-Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.639-644
    • /
    • 2010
  • Amphiphilic porphyrin derivatives have been synthesized and characterized by $^1H$ NMR and MALDI-TOF-MS. All porphyrin derivatives showed very high solubility to aqueous medium as well as hydrophobic organic solvent. The UV-vis absorption of the porphyrin derivatives showed significant broadness and decrease of maximum intensity of absorption in aqueous solution. SEM experiment showed the formation of spherical micellar structure. The $T_1$ relaxation time of aqueous medium was drastically decreased in the presence of Mn(III)-porphyrin derivative, indicating that the supramolecular micelle has strong possibility to use as a $T_1$ contrast agent.

Backbone Dynamics and Model-Free Analysis of N-terminal Domain of Human Replication Protein A 70

  • Yoo, Sooji;Park, Chin-Ju
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.1
    • /
    • pp.18-25
    • /
    • 2018
  • Replication protein A (RPA) is an essential single-stranded DNA binding protein in DNA processing. It is known that N terminal domain of RPA70 (RPA70N) recruits various protein partners including damage-response proteins such as p53, ATRIP, Rad9, and MRE11. Although the common binding residues of RPA70N were revealed, dynamic properties of the protein are not studied yet. In this study, we measured $^{15}N$ relaxation parameters ($T_1,\;T_2$ and heteronuclear NOE) of human RPA70N and analyzed them using model-free analysis. Our data showed that the two loops near the binding site experience fast time scale motion while the binding site does not. It suggests that the protein binding surface of RPA70N is mostly rigid for minimizing entropy cost of binding and the loops can experience conformational changes.

Determination of Correlation Times of New Paramagnetic Gadolinium MR Contrast Agents by EPR and 17O NMR

  • Kim, Hee-Kyung;Lee, Gang-Ho;Kim, Tae-Jeong;Chang, Yong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.849-852
    • /
    • 2009
  • The work describes EPR and 17O NMR measurements followed by theoretical calculation of the rotational correlation time $({\tau}_R)$, the water residence time $({\tau}_m)$, and the longitudinal electronic spin relaxation time $(T_{le})$(T_1e) for two new gadolinium complexes 1 and 2 of the type [$Gd(L)(H_2O)$] (L = tranexamic esters) in order to investigate their efficiency as a paramagnetic contrast agent (PCA). Of three correlation times, τR plays a major and predominant role to the unusually high relaxivity of 1 and 2 as compared with that of clinically approved MR CAs such as [$Gd(DTPA)(H_2O)]2‐ (Magnevist${\circledR}$), [Gd(DTPA-BMA)(H2O)] (Omniscan${\circledR}$), and $[Gd(DOTA)(H_2O)]^-$ (Dotarem${\circledR}$). The presence of bulky tranexamic ester in the ligand seems to be responsible for the conformational rigidity, which in turn causes such great an increase in ${\tau}_R$.

The Feasibility Study of 3-D Magnetic Resonance Neurograms (자기공명단층촬영장치를 이용한 신경조영영상의 기초연구)

  • Mun, C.W.;Lee, S.Y.;Lim, T.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.28-30
    • /
    • 1993
  • We have investigated the feasibility study, especially for optimal TR, to obtain 3-D MR neurographic imaging (neurograms or nervography) which shows the distribution of peripheral nerve fibers at the human forearm using 4.7 T magnet. To peform a successful formation of MR neurographic imaging, nerve signal should be separated from the other signal comes from surrounding muscle or fat, because nerves are usually embeded in muscle or fat. Generally, it is well known that nerve has shoter T1 value than that of muscle. Thus, repetition time was optimized to maximize the signal intensity defference between the muscel and nerve. We have also used spin-echo(SE) sequence with long echo time($60{\sim}90\;msec$) to enhance the different signal intensity between muscles and pheriperal nerves base on the fact that muscle tissue has longer T2 relaxation lime than that or nerve.

  • PDF