• 제목/요약/키워드: T-gap

검색결과 990건 처리시간 0.027초

리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향 (Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

결합 갭의 영향을 고려한 링 공진기의 설계 (The Design of Ring Resonator with Considering Effect of Coupling Gap)

  • 오데레사;김흥수
    • 전자공학회논문지D
    • /
    • 제36D권8호
    • /
    • pp.27-35
    • /
    • 1999
  • 링 공진기의 반경은 공진 주파수에 의해서 결정된다. 실제적으로 파자아의 정수 배인 원주를 갖는 링 공진기는 설계하고자 하는 공진 주파수에 맞게 설계하기가 어렵다. 본 논문에서는 결합 갭을 갖는 링 공진기가 원하는 공진 주파수에서 공진할 수 있도록 설계하는 방법을 제시한다. 전송선로 해석법을 이용하여 갭 크기에 따라 반경을 줄일 수 있는 관계식을 유도하고, 유전율에 따라서 반경을 결정할 수 있는 조건식을 제시한다. 새로운 방법에 의해 설계된 링 공진기는 크기 면에서 초기의 공진 주파수에 의해 설계한 링 공진기 크기의 1/3정도의 크기를 갖고, 초기에 설계하고자 하는 정확한 공진 주파수를 갖는다. $S_{11}$이 통과대역에서 많이 감쇠하는 특성을 얻기 위해서 링 공진기와 인접하는 결합선로를 T형으로 설계한다. 이러한 병렬 결합 선로의 캐패시턴스는 갭 캐패시턴스 보다 훨씬 적기 때문에 공진 주파수에 영향을 주지 않는다.

  • PDF

사상체질에 따른 여대생의 건강 특성 분석과 BMI에 영향을 미치는 요인 (Study of health characteristics of female college students according to sasang constitution and factors affecting BMI)

  • 김민정;이수진
    • 사상체질의학회지
    • /
    • 제30권3호
    • /
    • pp.48-61
    • /
    • 2018
  • Objectives The purpose of this study was to investigate the ordinary symptoms, special symptoms and Body Mass Index (BMI) according to Sasang constitution in female college students. Also, we aimed to analyze the factors affecting BMI. Methods Forty-four female college students participated in this study. Sasang Constitution was determined by Questionnaire for Sasang Constitution Classification (QSCC) II. BMI was measured and ordinary symptoms were acqired through the questionnaire. Special symptoms was determined by Fatigue Severity Index (FSS), Premenstrual Symptom Screening Tool (PSST), ROME III, Ocular Surface Disease Index (OSDI), respectively. For statistical analysis, t-test, analysis of variance and correlation test has been used. Results There existed significant differences in ordinary symptoms and special symptoms between sasang constitutions. Taeumin had higher urine frequency than soyangin, soeumin had higher gap of feces than taeumin. Taeumin had higher BMI and ROME III score than soyangin and soeumin. They showed significant differences in ordinary symptoms and special symptoms according to BMI. Overweight and obese group is higher in water intake than low and normal group. Low weight and normal group is higher in gap of feces than overweight and obese group. High score group in PSST and ROME III showed high BMI than low score group. We analyzed the factors that affect BMI. BMI are highly correlated with systolic and diastolic blood pressure. Also, FSS, PSST, ROME III and OSDI showed high correlation with each other. Conclusion Urine frequency and gap of feces are different among sasang constitutional types. The obese group and normal group showed significant differences in water intake, gap of feces, PSST and ROME III score. It is found that factors that affecting BMI are systolic and diastolic blood pressure. These results may lead to identifying the causes and factors of obesity in female college students related to Sasang constitution.

공공부문의 사이버보안 교육격차 해소를 위한 탐색적 연구 (Are There Any Solutions for the Cybersecurity Education Gap in the Public Sector?)

  • 이송하;전효정;김태성
    • 정보보호학회논문지
    • /
    • 제31권5호
    • /
    • pp.973-985
    • /
    • 2021
  • 우리나라는 명실상부한 전자정부 강국으로서 오랜 기간의 경험과 잘 구축된 정보통신 인프라를 기반으로 일찌감치 행정업무의 효율성과 국민의 편의성은 확보했지만, 그만큼 크고 작은 사이버 공격에 항시 노출되어 있다. 행정 및 공공부문의 사이버보안 대응력 및 회복력 확보는 국가경쟁력의 중요한 요소이며, 이를 위해 잘 훈련된 사이버보안 전문인력을 확보하고 재교육을 통해 계속해서 역량개발을 지원해야 한다. 하지만 국가균형발전사업으로 기관과 인력이 지방으로 이전하였음에도 교육시설의 이전이나 확장은 이루어지지 않아, 오히려 재교육을 통한 역량개발의 기회는 박탈되고 있는 것은 아닐지에 대한 논의가 필요한 시점이다. 본 연구는 공공부문 사이버보안 교육기회나 요구사항에 있어 지역, 기관, 인력의 특성에 따라 격차가 있는지 실증하고자 한다. 더불어 실증 결과를 바탕으로 공공부문 사이버보안 인력의 교육격차 해소방안을 제안하고자 한다.

Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro (Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro)

  • 이태희;이하빈;김지환
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

급속소결이 다층 지르코니아 치과보철물의 변연 및 내면 적합도에 미치는 영향 (Effect of the speed sintering schedule on the marginal and internal gaps of multi-layered zirconia prothesis)

  • 김세연;김재홍
    • 대한치과기공학회지
    • /
    • 제44권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: The purpose of this in vitro study is to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of multi-layered zirconia prothesis by speed sintering. Methods: The two specimen types come from the same manufacturer but differ in the ingredients in layered zirconia and indication, that is anterior and posterior. The designs of both specimens were full contour crowns, and a total of 20 pieces were repeatedly fabricated, 10 for each group. The specimens were divided into two subgroups (n=10) and sintered with various total times (4 hours, 8 hours) at the maximum temperature (1,530℃). The gap between the two groups of multi-layered zirconia prostheses was measured using a silicone replica technique of 2D analysis method. The independent sample t-test was then used to compare and analyze the data obtained from the two groups (α=0.05). Results: The marginal and internal gap was superior in the 8-hour compared to the 4-hour group, and the results exhibited significant differences (p<0.05). All specimens showed that using the speed sintering schedule does not exceed the clinically permitted value of 120 ㎛, meaning zirconia prothesis using the speed sintering was adequate. Conclusion: The sintering condition is shown to affect the marginal and internal gaps of multi-layered zirconia restoration.

Bridgman법으로 성장한 CdIn2Te4 단결정의 광전류 온도 의존성 (Temperature dependence of photocurrent for CdIn2Te4 single crystal grown by Bridgman method)

  • 유상하;홍광준
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.157-157
    • /
    • 2003
  • 수평 전기로에서 CdIn2Te4 다결정을 용융법으로 합성하고 Bridgman법으로 tetragonal structure의 c축에 평행한 CdIn2Te4 단결정을 성장시켰다. c축에 평행한 시료의 광흡수와 광전류 spectra를 293K에서 10K까지 측정하였다. 광흡수 spectra에 의해 band gap Eg(T)는 varshni공식에 따라 계산한 결과 1.4753eV-(7.78$\times$$10^{-3}$eV/K)T$^2$/(T+2155K)임을 확인하였다. Hall 효과는 van der Pauw 방법에 의해 측정되었으며, 온도에 의존하는 운반자 농도와 이동도는 293K에서 각각 9.01$\times$$10^{16}$ /㎤, 219 $\textrm{cm}^2$/V.S였다. 광전류 스펙트럼으로부터 Hamilton matrix(Hopfield quasicubic mode)법으로 계산한 결과 crystal field splitting $\Delta$cr값이 0.2704 eV이며 spin-orbit $\Delta$so 값은 0,1465 eV임을 확인하였다. 10K일 때 광전류 봉우리들은 n=1일때 Al-, Bl-와 Cl-exciton 봉우리임을 알았다.

  • PDF

맥스웰 응력텐서의 물리적 의미의 고찰 (On the Physical Meaning of Maxwell Stress Tensor)

  • 최홍순;박일한;문원규
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.725-734
    • /
    • 2009
  • Maxwell stress tensor is one of the methods which are generally used for electromagnetic force calculation. In this paper, it is presented that Maxwell stress tensor T and n${\cdot}$T have no physical meaning and therefore should not be used as sources of mechanical force for deformations or dynamics. The divergence of Maxwell stress tensor ${\nabla}{\cdot}T$ is the one which can acquire a physical identity and is electromagnetic body force density by an action at a distance like a gravity. This result can be derived from the principle of power balance, and also verified by some thought experiments. The virtual air-gap approach is proposed as a valid solution for the calculation of the body force.