• Title/Summary/Keyword: T-Box test

Search Result 111, Processing Time 0.023 seconds

Effect of Organizational Diagnosis, Job Satisfaction and Organizational Commitment of a Single-grade Korean Medicine Hospital Using Six-Box Model (Six-Box Model을 이용한 일개대학 부속 한방병원의 조직진단과 직무만족, 조직몰입에 미치는 영향)

  • Ahn, Hwa-Young;Kwon, Sung-Bok
    • The Korean Journal of Health Service Management
    • /
    • v.12 no.1
    • /
    • pp.35-46
    • /
    • 2018
  • Objectives : The purpose of this study was to present basic data on organizational changes in a Korean medicine hospital by performing organizational diagnosis and examining the job satisfaction and organizational commitment of the hospital. Methods : The subjects were a total of 218 employees in four Korean medicine hospitals, and data were collected from 1st to 25th September 2015. Using SPSS 21.0, frequency analysis, technical statistical analysis, t-test, ANOVA, Pearson's correlation analysis, and multiple regression analysis were performed. Results : The Korean medicine hospital tended to value relationships, the rewards for and attitudes towards change were low. The number of participants in this study with higher organizational diagnosis scores was high for job satisfaction and organizational commitment, and there was a strong positive correlation. It was seen that rewards, relationship, helpful mechanisms, and leadership among organizational diagnosis areas had an effect on job satisfaction, and helpful mechanisms, purposes, and leadership had an effect on organizational commitment. Conclusions : These findings will be useful because policies, research, and education are needed to facilitate organizational changes in Korean medicine hospitals.

Study on the Adsorption of Antibiotics Trimethoprim in Aqueous Solution by Activated Carbon Prepared from Waste Citrus Peel Using Box-Behnken Design (박스-벤켄 설계법을 이용한 폐감귤박 활성탄에 의한 수용액 중의 항생제 Trimethoprim의 흡착 연구)

  • Lee, Min-Gyu;Kam, Sang-Kyu
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.568-576
    • /
    • 2018
  • In order to investigate the adsorption characteristics of the antibiotics trimethoprim (TMP) by activated carbon (WCAC) prepared from waste citrus peel, the effects of operating parameters on the TMP adsorption were investigated by using a response surface methodology (RSM). Batch experiments were carried out according to a four-factor Box-Behnken experimental design with four input parameters : concentration ($X_1$: 50-150 mg/L), pH ($X_2$: 4-10), temperature ($X_3$: 293-323 K), adsorbent dose ($X_4$: 0.05-0.15 g). The experimental data were fitted to a second-order polynomial equation by the multiple regression analysis and examined using statistical methods. The significance of the independent variables and their interactions was assessed by ANOVA and t-test statistical techniques. Statistical results showed that concentration of TMP was the most effective parameter in comparison with others. The adsorption process can be well described by the pseudo-second order kinetic model. The experimental data of isotherm followed the Langmuir isotherm model. The maximum adsorption amount of TMP by WCAC calculated from the Langmuir isotherm model was 144.9 mg/g at 293 K.

Difference in Lower Extremity Landing Biomechanics between Male and Female Ballet Dancers During the Box Drop Landing (박스 드롭 착지 시 남자와 여자 발레 무용수들의 하지의 생체역학적 요인의 차이)

  • Choi, In-Ae;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.647-653
    • /
    • 2009
  • The purpose of this study was to investigate the differences between female and male ballet dancers in anterior cruciate ligament injury risk factors during the box drop landing task. Nine female and nine male collegiate ballet dancers participated in this study. Kinematic and ground reaction data were collected and combined with inverse dynamics to estimate the knee extensor and abductor moment. EMG data from the biceps femoris and rectus femoris were used to estimate the ratio of quadriceps-hamstrings muscle activity. No gender differences in anterior cruciate ligament injury risk factors were found during the box drop landing task. A significant relationship was found between female and male ballet dancers in the knee flexion angle.

A STUDY ON THE MARGINAL LEAKAGE OF CLASS II LIGHT CURING COMPOSITE RESIN RESTORATION ACCORDING TO FILLING METHODS (2급와동 광중합 복합레진의 충전방법에 따른 변연누출에 관한 실험적 연구)

  • Kim, Kyung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.55-72
    • /
    • 1993
  • The aim of this study was to compare the marginal leakage of class II light curing composite resin restoration according to filling methods. With using acid etching technique and dentin bonding agent, various methods were suggested to eliminate or reduce the marginal leakage. In this study, class II cavities were prepared in 100 extracted human premolars with cementum margin(1mm below the CEJ) and the teeth were randomly assigned to 5 groups of 20 teeth each. The teeth in group 1, 2, 3 and 4 were restored by direct filling methods using P-50 and Clearfil Photoposterior of 10 teeth each, but the method of insertion of the restorative materials varied with each group. And the teeth in group 5 were restored by inlay method using Kulzer Inlay and CR Inlay. Filling methods are as follows : Group 1 : The composite resin was inserted in one layer in the proximal box and one layer in the occlusal portion. Group 2 : Insertion was in two equally thick horizontal layers in the proximal box. Group 3 : Insertion was in two diagonally placed layers in the proximal box. Group 4 : The composite resin was inserted in the same way as in group 3 except that a glass ionomer liner was first placed on the axial wall and gingival floor. Group 5 : The teeth were restored by Inlay technique using dure cure resin cement. All the teeth were thermocycled, stained with 1 % methylene blue solution, sectioned mesiodistally, and scored for marginal leakage. To compare the marginal leakage, ANOVA and T-test were used in analysis. The following results were obtained : 1. In direct filling methods, there was no significant difference in marginal leakage at both occlusal and cervical margins. 2. In all groups, occlusal margin showed significantly less leakage than cervical margin. 3. In group using glass ionomer liner, there was no significant reduction of marginal leakage at the cervical margin. 4. The group restored by inlay method showed significantly less marginal leakage than groups restored by direct filling methods at both occlusal and gingival margins. 5. There was no significant difference in each group according to filling materials.

  • PDF

A Study on Bending Fatigue Strength of One Side Fillet Welded T-Joint by SM 490A steel (Sm 490A강으로 제작된 T형 편면용접이음재의 굽힘피로강동에 관한 연구)

  • 엄동석;강성원;이태훈;이해우;조수형
    • Journal of Welding and Joining
    • /
    • v.16 no.5
    • /
    • pp.134-141
    • /
    • 1998
  • In this study, a fillet size for bending fatigue strength of one side fillet welded T-joint, used in box type girder and other welding structure, was investigated by bending fatigue test with or without edge preparation and burn through, with variation of joint shape. As a result, the following conclusions were obtained. (1) In one side fillet welded T-joint, the larger the leg length, the greater the bending fatigue strength. The increase in bending fatigue strength. (2) One side filet welded T-joint with edge preparation showed higher bending fatigue strength than that with twofold-large leg length and without edge preparation. (3) In one side fillet welded T-joint without edge preparation, both manual welding and automatic welding were carried out with same condition. In this case, automatic welding shoed deeper penetration and more increased horizontal leg length than manual welding, so that automatic welding offers grater bending fatigue strength. (4) For one side fillet welded T-joint without edge preparation, the ratio(h/t) of the leg length (h) and the main plate thickness (t) in which toe crack can occur was 1.2 over. (5) In one side fillet welded T-joint with edge preparation, the burn through led to reduced bending fatigue strength. However, this bending fatigue strength was higher than that of one side fillet welded T-joint without edge preparation and with a larger leg length.

  • PDF

Construction of the Phosphate-Limitation Inducible Expression Vector Containing the phoA Promoter of Enterobacter aerogenes (Enterobacter aerogenes 의 phoA 유전자 Promoter를 이용한 인 제한환경에서 발현하는 벡터 구축)

  • 장화형;고병훈;박신영;이성호;김성진;임유정;한갑진;김영호;이영근
    • Korean Journal of Microbiology
    • /
    • v.38 no.4
    • /
    • pp.318-321
    • /
    • 2002
  • To induce recombinant protein under phosphate restricted conditions such as soil, we have constructed the expression vector (pEAAP) with phoA gene promoter of Enterobacter aerogenes. To construct the pEAAP, deletion of the T7 promoter and lac operator from pET-22b(+) by BglII-XhoI digestion and addition of the phoA gene promoter (containing the pho box) were performed. To test pEAAP as an expression vector controled by phosphate limitation, pEAPHY1 was constructed with the phytate gene (Bsa-phy1) of Bacillus subtillis var. amyloliquefaciens (KCTC 8913P). Under the phosphate-limitation condition, CK-PHY1 ( Escherichia coli JM109 was transformed with pEAPHY1) expressed the 41 kD Bsa-Phy1 . Also CK-PHY1 formed the clear zone in solid medium containing phytate as a sole phosphate source.

Evaluating fire resistance of prestressed concrete bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Hou, Wei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • v.62 no.6
    • /
    • pp.663-674
    • /
    • 2017
  • This paper presents an approach for evaluating performance of prestressed concrete (PC) bridge girders exposed to fire. A finite element based numerical model for tracing the response of fire exposed T girders is developed in ANSYS. The analysis is carried out in three stages, namely, fire temperature calculation, cross sectional temperature evaluation, and then strength, deformation and effective prestress analysis on girders exposed to elevated temperatures. The applicability of the computer program in tracing the response of PC bridge girders from the initial preloading stage to failure stage, due to combined effects of fire and structure loading, is demonstrated through a case study, and validated by test data of a scaled PC box girder under ISO834 fire condition. Results from the case study show that fire severity has a significant influence on the fire resistance of PC T girders and hydrocarbon fire is most dangerous for the girder. The prestress loss caused by elevated temperature is about 10% under hydrocarbon fire till the girder failure, which can lead to the increase in deflection of the PC girder. The rate of deflection failure criterion is suggested to determine the failure of PC T girder under fire.

A Single-Blind Randomized Controlled Pilot Study of Electroacupuncture with Transcranial Direct Current Stimulation for Improving Motor Function in Stroke Patients (뇌졸중 환자의 운동 기능 개선에 대한 전침과 경두개직류전기자극 병행 치료의 단일 맹검 무작위 대조군 예비 연구)

  • Irang Nam;Jisoo Baik;Yong-Il Shin;In Lee
    • The Journal of Internal Korean Medicine
    • /
    • v.45 no.4
    • /
    • pp.646-662
    • /
    • 2024
  • Objectives: This study aimed to confirm the effectiveness and safety of electroacupuncture (EA) with transcranial direct current electrical stimulation (tDCS) on motor function improvement in stroke patients. Methods: This study was conducted on patients diagnosed with stroke more than 2 weeks but within 12 months of onset. A total of 22 patients were randomly assigned to the experimental and control groups. The experimental group received EA and tDCS treatment, while the control group received sham EA and sham tDCS treatment. Assessments were conducted using the Korean version of the Fugl-Meyer Assessment (K-FMA) scores, grip and pinch strength tests, Box and Block test (BBT), Nine-hole peg test (9HPT), Berg balance scale (BBS), and the Korean version the Modified Barthel Index (K-MBI) scores. Adverse events were recorded at each intervention. Results: No statistically significant differences were observed in general characteristics between the two groups. The K-FMA, BBS, and K-MBI scores of both groups increased significantly after the intervention, but there was no significant difference between the two groups. Although hand strength and dexterity improved after intervention in both groups, the changes were not statistically significant. In the experimental group, the lateral pinch score increased significantly after the intervention, but this increase was not significant compared to the control group. There was no significant difference in the incidence of adverse events between the two groups. All nine reported adverse reactions were minor, with no moderate or severe adverse reactions reported. Conclusion: This study confirmed the potential effectiveness and safety of EA with tDCS in improving motor function in stroke patients.

Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties (고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가)

  • Jung, Ye-Lee;Chae, Young-Jin;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

An Experimental Evaluation of Structural Performance for the Beam to Column Joints in Unit Modular System (유닛 모듈러 기둥-보 조인트의 구조 성능에 대한 실험적 평가)

  • Lee, Sang Sup;Bae, Kyu Woong;Park, Keum Sung;Hong, Sung Yub
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.255-265
    • /
    • 2013
  • The major goal of this study is to develop the industrialized structural system that can build high-rise buildings using the box-shaped steel frames such as a unit module system. In order to achieve such a goal, we need the advanced details for joints that consist in a single unit. Furthermore we also need to commercialize the unit modular building system through the basic experiments, research of theoretical analysis and the achievement of seismic performance. This study derived to develop the derails in the beam-to-column joint and to carry out structural performance test. Test results, a joint with thickness of 6.0T can be possible to maintain the plastic rotational angle for strength and seismic performance. Therefore, joint with thickness of 6.0T is able to apply when considering reinforcement in the local of stress concentration.