• 제목/요약/키워드: T-Box test

검색결과 111건 처리시간 0.026초

고충돌에너지 흡수용 알루미늄 크래쉬박스 개발 (Development of Al Crash Box for High Crashworthiness Enhancement)

  • 유정수;김석봉;이문용;허훈
    • 소성∙가공
    • /
    • 제17권3호
    • /
    • pp.182-188
    • /
    • 2008
  • Crash box is one of the most important automotive parts for crash energy absorption and is equipped at the front end of the front side member. The specific characteristics of aluminum alloys offer the possibility to design cost-effective lightweight structures with high stiffness and excellent crash energy absorption potential. This study deals with crashworthiness of aluminum crash box for an auto-body with the various types of cross section. For aluminum alloys, A17003-T7 and A17003-T5, the dynamic tensile test was carried out to apply for crash analysis at the range of strain from 0.003/sec to 200/sec. The crash analysis and the crash test were carried out for three cross sections of rectangle, hexagon and octagon. The analysis results show that the octagon cross section shape with A17003-T5 has higher crashworthiness than other cross section shapes. The effect of rib shapes in the cross section is important factor in crash analysis. Finally, new configuration of crash box with high crash energy absorption was suggested.

Asymptotic Relative Efficiency of t-test Following Transformations

  • Yeo, In-Kwon
    • Journal of the Korean Statistical Society
    • /
    • 제26권4호
    • /
    • pp.467-476
    • /
    • 1997
  • The two-sample t-test is not expected to be optimal when the two samples are not drawn from normal populations. According to Box and Cox (1964), the transformation is estimated to enhance the normality of the tranformed data. We investigate the asymptotic relative efficiency of the ordinary t-test versus t-test applied transformation introduced by Yeo and Johnson (1997) under Pitman local alternatives. The theoretical and simulation studies show that two-sample t-test using transformed date gives higher power than ordinary t-test for location-shift models.

  • PDF

Numerical simulation of dynamic segregation of self-consolidating concrete (SCC) in T-box set-up

  • Hosseinpoor, Masoud;Khayat, Kamal H.;Yahia, Ammar
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.297-310
    • /
    • 2017
  • A CFD software was used to simulate free surface flow of SCC in the T-Box test. In total, seven simulations were developed to study the effect of rheological parameters on the non-restricted flow performance of SCC in both horizontal and vertical directions. Different suspending fluids having five plastic viscosity values between 10 and 50 Pa.s, three yield stress values between 14 and 75 Pa, one density of $2500kg/m^3$, and one shear elasticity modulus of 100 Pa were considered for suspension of 178 spherical particles of 20-mm diameter and $2500kg/m^3$ density. The results of the simulations are found to correlate well to changes in rheological parameters of the suspending fluid. Plastic viscosity was shown to be the most dominant parameter affecting flowability and dynamic stability compared to the yield stress. A new approach was proposed to evaluate performability of SCC based on a trade-off between flowability and dynamic stability.

호흡기보호구의 밀착계수와 안면구조의 관계 (Correlation of Fit Factors for Respirators and Anthropometric Dimension)

  • 한돈희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제31권3호
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

직류철도차량에 대한 자계측정 및 분석 (Measurement and Analysis of Electromagnetic field for DC electric railway train)

  • 장동욱;김민철;이장무;한문섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

환아에게 적용한 얼굴그림 동통척도의 타당도 및 신뢰도 연구 (Testing the Validity and Reliability of FIPS(Face Interval Pain Scale) with Children림s Pain from Intramuscular Injection)

  • 김주희;김분한
    • 대한간호학회지
    • /
    • 제24권3호
    • /
    • pp.461-472
    • /
    • 1994
  • The main purpose of this study was to test the validity and reliability of FIPS as an assessment tool for pain in children. The subject were 81 children whose ages ranged from 3 to 14 years old who were experiencing pain from an intramuscular injection. 40 were being seen in a local primary hospital and 41 in a university hospital. The data were collected in two settings at a 6 month interval, the first was on Nov. 5th 1991 in a local clinic by one doctor, the second was on May 1st. 1992 in a university hospital by two nurse. McGrath's(1985) face interval cards and weight box scale which is a numeral scale that contains from one to five boxes of cards were used as measures. To analyze the subject's ability to use the face scale and weight box scale, statistical frequency was employed. To determine the difference in the rated pain in-tensity on the face interval scale and the weight box, Pearson correlation coefficient and t-test were employed. To compare the difference in the rated pain intensity of the face interval scale and the weight box scale according to subject's general characteristics, X²-test was employed. The findings were as follows : 1. The subject's ages were from 3 to 14 with a mean age of 8.3 years old. There were 54(66.7%) male children and 27(33.3%) female children. 2. The number of subjects who correctly displayed cards ranging from none to severe pain was 66(81.5%) and the number who correctly compared two cards 3 times was 73(90.l%). 3. Correlation coefficients between each level card of the FIPS and WBS (Weight Box Scale) were r=.52∼.80 P<0.01. 4. There was no statistical difference in rating of the intensity on the FIPS and WBS.(t=1.12∼l.02, P<0.22∼0.45). 5. The differences in rating pain intensity according to the children's general characteristics were re-lated to age(X²=8.94, P<0.05), but not to sex (X²=0.23, P=0.80).

  • PDF

Remarks on correlated error tests

  • Kim, Tae Yoon;Ha, Jeongcheol
    • Journal of the Korean Data and Information Science Society
    • /
    • 제27권2호
    • /
    • pp.559-564
    • /
    • 2016
  • The Durbin-Watson (DW) test in regression model and the Ljung-Box (LB) test in ARMA (autoregressive moving average) model are typical examples of correlated error tests. The DW test is used for detecting autocorrelation of errors using the residuals from a regression analysis. The LB test is used for specifying the correct ARMA model using the first some sample autocorrelations based on the residuals of a tted ARMA model. In this article, simulations with four data generating processes have been carried out to evaluate their performances as correlated error tests. Our simulations show that the DW test is severely dependent on the assumed AR(1) model but isn't sensitive enough to reject the misspecified model and that the LB test reports lackluster performance in general.

Ground effects on wind-induced responses of a closed box girder

  • Mao, Wenhao;Zhou, Zhiyong
    • Wind and Structures
    • /
    • 제25권4호
    • /
    • pp.397-413
    • /
    • 2017
  • When bridges are constructed with lower heights from the ground, the formed channel between the deck and the ground will inevitably hinder or accelerate the air flow. This in turn will have an impact on the aerodynamic forces on the deck, which may result in unexpected wind-induced responses of bridges. This phenomenon can be referred to "ground effects." So far, no systematic studies into ground effects on the wind-induced responses of closed box girders have been performed. In this paper, wind tunnel tests have been adopted to study the ground effects on the aerodynamic force coefficients and the wind-induced responses of a closed box girder. In correlation with the heights from the ground in two ground roughness, the aerodynamic force coefficients, the Strouhal number ($S_t$), the vortex-induced vibration (VIV) lock-in phenomena over a range of wind velocities, the VIV maximum amplitudes, the system torsional damping ratio, the flutter derivatives, the critical flutter wind speeds and their variation laws correlated with the heights from the ground of a closed box girder have been presented through wind tunnel tests. The outcomes show that the ground effects make the vortex-induced phenomena occur in advance and adversely affect the flutter stability.

FRP 보강재의 Box 형상 설계 및 거동 평가에 관한 연구 (A Study on the Behavior Evaluation & Box Shape Designs of FRP Stiffeners)

  • 정우영;송영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.165-168
    • /
    • 2008
  • 본 연구에서는 철근콘크리트 구조물의 보강에 이용되는 유리섬유강화 복합재료(Glass Fiber Reinforced Polymer, GFRP) 형상에 관한 연구로서 콘크리트의 피복두께 및 FRP 보강재의 형상(Plate, Box)을 실험 변수로 하여 FRP 보강 철근콘크리트 보의 거동 평가 관한 연구를 수행하였다. 이를 위하여 본 연구에서는 T. J. Teng 등이 제안한 설계식을 이용하여 보강량을 결정하였고 기존의 FRP Plate 보강재의 성능개선을 위하여 FRP Sandwich box 보강재를 설계, 적용하여 보았다. 연구의 결과 예상과 달리 FRP Plate 보강재가 Sandwich box 보강재보다 보강효과가 우수한 것으로 조사되었으며, 이는 보강재 제작상의 한계점 및 core 재료가 너무 약하여 Sandwich box 보강재의 Top Plate와 Bottom Plate가 일체화 거동을 하지 못하여 나타난 결과로 사료된다.

  • PDF

Control of tendon driven one-link manipulator

  • Choi, H.R.;Lee, Y.T.;Kim, J.H.;Chung, W.K.;Youm, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.290-295
    • /
    • 1992
  • Tendon driven method to drive one joint using two actuators is developed and implemented. While the method has advantages over conventional transmissions, it also has several drawbacks like tendon slack, elongation and endurability. In this paper, a compensation method of the intrinsic non-linearities of tendon is proposed to improve the performance of antagonistic tendon driven method. In this method, tendon tension measurement is prerequisite which is measured with strain gauge type tension sensor. The developed method is implemented on one link test bed with colocated and non-colocated position sensor.

  • PDF