• 제목/요약/키워드: T/R coil

검색결과 42건 처리시간 0.027초

사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계 (YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF

YBCO Coated Conductor의 과전류 특성해석 (Analysis of Over-current Characteristics in YBCO Coated Conductor)

  • 이찬주;남관우;강형구;고태국;석복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.693-694
    • /
    • 2006
  • In order to develop a high temperature superconducting(HTS) coil for the fault current limiter(FCL), the over-current characteristics in YBCO coated conductor(CC) with Ni-W alloy substrate are analyzed. The HTS wire is wound by bifilar winding method for resistive current limitation and it is operated in 65K sub-cooled nitrogen. In order to analyze the resistance and the temperature characteristics of the CC wire, an analysis program is developed considering all the composition materials except the buffer layer. Using this program, the temperature rise, the resistance development and the current limitation of CC are calculated depending on the applied voltage and the stabilizer materials. According to the analysis results, under the temperature restriction of 300K, the maximum voltage per meter is determined as 40V/m if the stabilizer is $25{\mu}m$ thick stainless steel at each side. Finally, the wire length needed for the distribution level HTS FCL is estimated.

  • PDF

지구자기장을 이용한 소구경 탄약 신관용 소형 회전수 계수 센서 (A miniaturized turn-counting sensor using geomagnetism for small-caliber ammunition fuzes)

  • 윤상희;이석우;이영호;오종수
    • 센서학회지
    • /
    • 제16권1호
    • /
    • pp.17-23
    • /
    • 2007
  • This paper presents a miniaturized turn-counting sensor (TCS) where the geomagnetism and high-rpm rotation of ammunition are used to detect the turn number of ammunition for applications to small-caliber turn-counting fuzes. The TCS, composed of cores and a coil, has a robust structure with no moving part for increasing the shock survivability in the gunfire environments of ${\sim}30,000$ g's. The TCS is designed on the basis of the simulation results of an electromagnetic analysis tool, $Maxwell^{(R)}$3D. In experimental study, the static TCS test using a solenoid-coil apparatus and the dynamic TCS test (firing test) have been made. The presented TCS has shown that the induction voltage of $6.5{\;}mV_{P-P}$ is generated at the magnetic flux density of 0.05 mT and the rotational velocity of 30,000 rpm. From the measured signal, the TCS has shown the SNR of 44.0 dB, the nonlinearity of 0.59 % and the frequency-normalized sensitivity of $0.26{\pm}0.01{\;}V/T{\cdot}Hz$ in the temperature range of $-30{\sim}+43^{\circ}C$. Firing test has shown that the TCS can be used as a turn-counting sensor for small-caliber ammunition, verifying the shock survivability of TCS in high-g environments.

급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성 (Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke)

  • 오근택;정홍량;임청환;조영기;하본철;홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.323-331
    • /
    • 2011
  • 본 연구는 급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 임상적 유용성을 평가하고자 하였다. 급성 허혈성 뇌경색 증상으로 응급실로 내원한 환자 중 확산강조영상(DWI)의 병변의 크기가 3 cm 이상이고 역동적 자화율대조 조영증강 관류자기공명(DSC)영상, 동맥스핀표지 관류자기공명(ASL)영상을 모두 시행한 22명과 정량적 분석을 위한 정상대조군 36명을 대상으로 하였다. 사용된 장비로는 Siemens Magnetom Verio 3.0 T이고 12 Chanel Head Coil을 사용하였다. 정성적 평가는 rMTT, TTP, rCBF, rCBV, ASL지도의 병변 인지도평가와 확산강조영상과 병변의 크기 비교평가를 하였고 정량적 평가는 각 관류영상의 평균 상대값을 Mann-Whitney U test를 사용하여 병변 그룹과 정상군 그룹의 유의성을 분석한 결과는 다음과 같다. 첫째, 병변의 인지도평가에서 TTP(95.5%), rCBF(95.5%), 지도가 가장 높았고, 둘째, 최종 뇌경색부위 연관성은 rCBV와 rCBF지도가 높게 나타났다. 셋째, 정량적 분석에서는 병변그룹의 평균 상대값은 유의하게 나타났다(p<0.05). 동맥스핀표지 관류자기공명(ASL)영상은 높은 병변의 인지율을 보여 임상에서 적용가능하다 생각되며, 정량적 상대값은 제시하기 어렵지만 참고적 자료로 사용될 수 있을 것이며 향후 지속적 연구를 한다면 뇌경색의 조기진단, 허혈성 반영부의 존재여부와 범위, 혈류역동학적평가가 가능함으로써 치료방침을 정하고 예후를 파악하는데 ASL영상이 유용할 것으로 사료된다.

등가회로 해석법에 의한 환단면형 유도전자펌프의 설계 (A design of the annular induction electromagnetic pump by equivalent circuit modelling)

  • 김희령;홍상희;황종선;민병태;남호윤;조만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

300MHz급 NMR Transceiver 설계 및 제작 (A Study on the 300MHz NMR Transceiver)

  • 박양하;진승오;원진임;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3210-3212
    • /
    • 2000
  • We designed and manufactured 300MHz NMR RF Transceiver. NMR system is composed of NMR Spectrometer, Superconductive Magnet and Pulse Programmer, GUI. NMR RF Transceiver is composed of transmitter, receiver, frequency synthesizer. T/R switch, main power amp., RF coil. To phase modulation, transmitter is composed of mixer, splitter and combiner et al. To weak signal detection, receiver is composed of pre-amp., filter, mixer et al. Each module is manufactured PCB. And installed NMR system to detect chemical component of specimen. In result, we can get the information of specimen.

  • PDF

원전 증기발생기세관 진단을 위한 와전류탐상 수치해석 (Numerical Analysis of ECT for Investigation of SG Tube in NPP)

  • 임건규;이향범
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.509-512
    • /
    • 2008
  • 본 논문에서는 원전 증기발생기세관 진단을 위한 와전류탐상의 전자기 수치해석을 수행하였다. 전자기적 특성을 해석하기 위하여 맥스웰 방정식을 이용하여 지배방정식을 유도하였고, 3차원 전자기 유한요소 프로그램인 OPERA 3D를 이용하여 전자기 수치 해석을 수행하였다. 신호해석을 위해 사용된 프로브의 종류는 배열와전류프로브이며, FBH 결함의 신호를 해석하였다. 결함의 깊이는 세관 두께의 40[%], 60[%] 및 100[%]로 하였다. 시험주파수는 100[kHz], 300[kHz], 400[kHz]를 사용하였고, 각각의 결함 및 시험주파수에 대한 결과를 비교 분석하였다. 본 논문의 결과는 앞으로 배열와전류프로브를 이용하여 원전 증기발생기세관 진단을 할 경우 신호 해석에 도움이 될 것으로 사료된다.

  • PDF

Comparisons and analysis on the prototype EU-DEMO TF CICC with Nb3Sn cable

  • Kwon, Soun Pil
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권4호
    • /
    • pp.31-39
    • /
    • 2017
  • European R&D on designing their version of a DEMO fusion tokamak has recently resulted in the testing of a prototype $Nb_3Sn$ Cable-in-Conduit Conductor (CICC) for the DEMO TF coil. The characteristics and reported results of low temperature performance tests with the prototype CICC sample are compared with those from CICC samples incorporating other recent $Nb_3Sn$ cable designs. The EU-DEMO TF CICC prototype shows performance characteristics similar to that of the ITER CS CICC with short twist pitch. This is a first for a CICC sample that does not have a circular cross section. Assessment of its internal magnetostatic self-field suggests that a reduction in the internal self-field due to the rectangular geometry of the EU-DEMO TF CICC prototype compared to one with a circular geometry may have contributed to the performance characteristics showing current sharing temperature ($T_{cs}$) initially increase then stabilize with repeated electromagnetic loading, similarly to ITER CS CICC results. However, constraints on the internal self-field are not a sufficient condition for this $T_{cs}$ characteristic to occur.

슬관절 연골 평가를 위한 자기공명영상 검사 시 지방 신호 억제 3D T2* Weighted 기법과 지방 신호 억제 3D SPGR 기법의 비교 및 유용성 평가 (The Comparative Analysis Study and Usability Assessment of Fat Suppressed 3D T2* weighted Technique and Fat Suppressed 3D SPGR Technique when Examining MRI for Knee Joint Cartilage Assesment)

  • 강성진
    • 한국자기학회지
    • /
    • 제26권6호
    • /
    • pp.219-225
    • /
    • 2016
  • 퇴행성 슬관절 연골 질환의 평가를 위하여 지방 신호 억제 3D SPGR 기법과 지방 신호 억제 3D $T2^*$ weighted 기법을 이용하여 자기공명영상을 획득하였다. 정량적 평가를 위해서 슬관절 연골을 내측대퇴연골(medial femoral cartilage, MFC), 내측경골연골(medial tibial cartilage, MTC), 외측대퇴연골(lateral femoral cartilage, LFC), 외측경골연골(lateral femoral cartilage, LFC), 슬개연골(patella cartilage, Pat) 구역으로 분류하여 관심영역을 설정한 후 각각의 신호강도, 신호 대 잡음비, 대조도 대 잡음비를 측정하였다. 측정된 값은 Mann-Whitney U-검정을 이용 두 기법간의 통계적 유의성을 검증하였다. 정성적 평가를 위해서 각각의 영상을 2명의 영상의학의가 관찰한 후 영상 내 인공음영, 연골의 경계, 조직 간 대조도, 병소의 묘사정도를 4점 척도(1점: 나쁨, 2점: 적당함, 3점: 좋음, 4점: 매우 좋음)로 평가하고, 그 결과를 바탕으로 Kappa-value 검정을 통해 통계적 유의성을 검증하였다. 영상획득에 사용된 장비는 3.0T MR system과 HD T/R 8ch knee array coil을 사용하였다. 정량적 분석결과, SNR 측정값을 토대로 한 두 기법 간의 통계적 유의성 검증 결과 MFC, LFC, LTC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. CNR 측정값의 통계적 유의성 검증 결과 MFC, LFC, Pat에서는 통계적으로 유의한 결과(p < 0.05)를 보였으나, MTC, LTC에서는 유의하지 않은 결과(p > 0.05)를 보였다. 정성적 분석결과, 영상의 평가항목별 결과 값의 평균을 비교해 보면 3D $T2^*$ weighted 영상에서 조금 높은 결과를 보였고, Kappa-value test를 이용한 두 관찰자간의 일치성 검증에서는 모든 평가항목에서 통계적으로 의미 있는 결과(p < 0.05)를 보였다. 결론적으로 3D $T2^*$ weighted 영상 기법은 3D SPGR 영상기법과의 비교에서 슬관절 연골의 묘사와 주변 조직 간의 대조도 및 병소의 묘사 등 영상의 평가에서 동등 및 그 이상의 진단적 가치를 낼 수 있다.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.