• Title/Summary/Keyword: T/L ratio

Search Result 999, Processing Time 0.028 seconds

ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load (측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구)

  • Cho Young-Jin;Kang Seok-Youn;Moon Jong -Sun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.

Simulation of SI-HCCI Transition in a Two-Stroke Free Piston Engine Fuelled with Hydrogen (수소 2행정 프리피스톤엔진의 SI-HCCI 변화에 관한 수치해석적 연구)

  • Hung, Nguyen Ba;Park, Kyuel;Lim, Ocktaeck
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.472-479
    • /
    • 2013
  • A free piston linear engine could be operated under HCCI combustion due to its variable compression ratios. To obtain HCCI combustion, the free piston linear engine needs a high compression ratio to achieve auto-ignition of the fuel/air mixture. In this study, an idea for obtaining a high compression ratio using the transition from SI combustion to HCCI combustion was proposed. The fuel used in this study is hydrogen, which is considered to be an environmentally friendly fuel. Besides, the effects of key parameters such as equivalence ratio (${\phi}$), load resistance ($R_L$) and intake temperature ($T_{in}$) on the SI-HCCI transition were numerically investigated. The simulation results show that the SI-HCCI transition is successful without any significant reduction of in-cylinder pressure as the intake temperature is increased from $T_{in}$=300K (SI mode) to $T_{in}$=450K (HCCI mode), while the load resistance and equivalence ratio are retained respectively at $R_L=120{\Omega}$ and ${\phi}$=0.6 in both SI mode and HCCI mode.

Phosphorus Removal (Characteristics by Anoxic Oxic Process) by Anoxic and Oxic Processed Combined with Iron Electrolysis (철 석출장치가 결합된 무산소.호기공정에 의한 인 제거 특성)

  • Kim, Min-Ho;Kim, Young-Gyu;Kim, Soo-Bok
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.502-509
    • /
    • 2010
  • In this study, the (phosphorous removal) the characteristics of phosphorous removal due to (the iron compound precipitated) iron compound precipitation by iron electrolysis in (the anoxic. oxic process) anoxic and oxic processes (equipped with the) in an iron precipitation device were analyzed. During the device operation period, the average concentration of BOD, T-N, and T-P were 219.9 mg/l, 54.6 mg/l and 6.71 mg/l, respectively. The BOD/$COD_{Cr}$ ratio was 0.74, and the BOD/T-N and BOD/T-P ratios were 4.0 and 32.8, respectively. The removal rate of (the organic matters) organic matter (BOD and $COD_{Cr}$) was very high at 91.6% or higher, and that of nitrogen was 80.5%. The phosphorous concentration (of the final) in the treated water was 0.43 mg/l (0.05-0.74 mg/l) on average, and the removal efficiency was high at 90.8%. The soluble T-P concentrations in (an) the anoxic reactor, oxic reactor (II) and final treated water were 1.99 mg/l, 0.79 mg/l and 0.43 mg/l, respectively, which indicated that the phosphorous concentration in the treated water was very low. Regardless of the changes in the concentrations of (organic matters) organic matter, nitrogen and phosphorous in the influent, the quality of the treated water was relatively stable and high. The removal rate of T-P somewhat increased with the increase in the F/M ratio in the influent, and it also linearly increased in proportion to the T-P loading rate in the influent. In the treatment process used in this study, phosphorous was removed (using) by the precipitated iron oxide. Therefore, the consumption of organic (matters) matter for biological phosphorus removal was minimized and (most of the organic matters were) was mostly used as the organic carbon source for the denitrification in the anoxic reactor. This (can be an economic) treatment process (without the need for the supply of additional organic matters) is economic and does not require the supply of additional organic matter.

ADPI Characteristics of a Line-Diffuser (라인-디퓨저의 ADPI특성에 관한 연구)

  • Lee, Jae-Heon;Cho, Young-Jin;Kang, Seok-Youn;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.958-964
    • /
    • 2001
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the ADPI(Air Diffusion Performance Index) vs. T/L(Throw/Length) curve listed in conventional guide does not consider the perimetric heating load. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and to propose a selection guide for proper diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI value are obtained numerically with various heat load ratios and air flow rates. The ADPI values by numerical result were compared with existing experimental data to verify the method for evaluation of ADPI proposed in present study. In case of a high side wall diffuser, the ADPI decreased with increases of the flow rate on every heat load ratio of present study except 0.75. Also, the ADPI vs. T/L curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee comport thermal environment when diffusers are installed in perimeter zone.

  • PDF

Haploid Plant Characteristics and Screening for T.M.V. Resistance from in Vitro Anther Culture of Nicotiana tabacum L. (담배 약배양에 의한 반수체식물의 특성과 T.M.V. 저항성 검정)

  • Ahn, D.M.;Lee, S.C.;Yoon, I.B.;Heu, I.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.22 no.1
    • /
    • pp.41-44
    • /
    • 1977
  • Production of haploids in vitro anther culture of Nicotiana tabacum L. was oriented in a large number on a chemically defined culture medium. The haploids were screened for T.M.V. resistance and the segregating ratio in F$_1$ were in good agreement with the expected ratio.

  • PDF

Characteristics of Water and Sediment Qualities in the Oncheon Stream, Busan during Summer Rainy Season (부산 온천천의 하계 우수기 수질 및 퇴적물 환경 특성)

  • Lee, Young-Hyeong;Moon, Changho;Kang, Hyun-Jung;Choi, Seong-Ryul;Kim, Suk-Hyun
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.659-672
    • /
    • 2020
  • Water and sediment qualities were investigated in the Oncheon Stream and at the Wondong bridge of the Suyoung River, during the summer rainy season, 2019. Dissolved oxygen (DO) showed the lowest levels at 4.7 and 5.0 m/L, and biogeochemical oxygen demand (BOD) showed the highest at 5.3 mg/L downstream where the tributary flows into the main river. Chemical oxygen demand (COD) increased from 2.0 to 5.9 mg/L on average as it flowed downstream, The COD/BOD ratio decreased gradually as it flowed downstream, reaching 1.0. However, COD/BOD ratio at the Wondong bridge was 5.8-22.2, indicating that easily biodegradable and non-biodegradable organic matter flows into the Oncheon Stream and Suyoung River, respectively. Total nitrogen (T-N) / total phosphorus (T-P) ratio tended to decrease from 72 to 21 as it flowed downstream, measuring 71 to 86 at the Wondong bridge. The water quality index (WQI) generally improved better than grade IV after heavy rainfalls. However, DO and T-P were the parameters that deteriorated the WQI. Ignition loss (IL), COD, T-N, and T-P of sediments had distribution of 1.44 ± 1.01%, 0.35 ± 0.16%, 43 ± 63 mg/kg, and 10.9 ± 21.9 mg/kg, respectively. These were several times lower than the annual averages of IL, T-N, and T-P in 2017 before the dredging project was conducted in the first half of 2018.

The Study on the Gragting Rate MAA onto Silk Fiber by Redox System (Redox계에 의한 MAA Gragt 속도에 관한 연구)

  • 배도규;김종호
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.62-66
    • /
    • 1997
  • The MAA graftings in silk fiber were done by redox system for the purpose of investingating the effect of ferrous sulfate additive on the grafting rate and graft ratio in various conditions. The graft ratio was higher in redox graft system than in peroxide graft system and the graft ratio in redox graft system was also higher depending on decrease of ferrous sulfate additive. The saturation graft ratio obtained by empirical equation, log X=K/t, was increasing depending on the increase of ferrous sulfate additive. Initial grafting rate was increased but the latter grafting rate was decreased in redox graft system. The effects of liquor ratio(L.R.) on the graft ratio in redox graft system, were higher in high L.R. than in low L.R..

  • PDF

Ring-Opening Polymerization of L-lactide with Glycidol as Initiator (Glycidol을 개시제로 이용한 L-lactide 개환중합)

  • Yim, Jin-Heong;Kim, Da Hee;Ko, Young Soo
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.606-612
    • /
    • 2013
  • Glycidol-poly(lactide) (Gly-PLA) were synthesized via L-lactide ring opening polymerization with glycidol as an initiator and $Al(O-i-Pr)_3$ catalyst. The structure of Gly-PLA was analyzed and successfully confirmed by 1H NMR. The OH group of glycidol in Gly-PLA was absent according to the $^1H$ NMR analysis, indicating that the terminal OH group of glycidol successfully served as an initiator in the L-lactide polymerization. The solution and bulk polymerizations of L-lactide with glycidol were performed to examine the effect of L-lactide/glycidol molar ratio, polymerization temperature and time on the molecular characteristics of Gly-PLA. The conversion and molecular weight increased with an increase in L-lactide/glycidol molar ratio. Gly-PLA showed the bimodal type DSC curve. The low $T_m$ peak of low molecular weight reduced but the high $T_m$ peak of high molecular weight increased as L-lactide/glycidol molar ratio increased.

Significance of varying concentrations of T-2 toxin on growth performance, serum biochemical and hematological parameters in broiler chickens

  • Singh, Ram;Park, Sungkwon;Koo, Jin Su;Kim, In Ho;Balasubramanian, Balamuralikrishnan
    • Journal of Animal Science and Technology
    • /
    • v.62 no.4
    • /
    • pp.468-474
    • /
    • 2020
  • The study was to determine the effects of diverse concentrations of T-2 toxin in broiler diet. Three hundred 1-day-old chicks with initial body weight of 46 ± 0.52 g were chosen and randomly assigned into five dietary treatments with 5 replicate cages and 12 broilers per cage for 42 d feeding trial. Dietary treatments were prepared with basal diets containing 0 (T1), 50 (T2), 100 (T3), 150 (T4), 200 (T5) ppb T2-toxin. Significant results were observed in the decreased intake of feed, feed conversion ratio (FCR), body weight gain (BWG), level of serum protein, cholesterol and hemoglobulin of broilers in increased concentration of the T-2 toxin in diet (150 and 200 ppb) groups than control. Also, observed that the uric acid, serum glutamic pyruvic transferase (SGPT), serum glutamic oxaloacetic transferase (SGOT) and Heterophil/Lymphocyte (H/L) ratio value were significantly higher (p < 0.05) in groups T4 and T5 than control. However, the BWG, feed intake and FCR, as well blood biochemical profiles of serum protein, cholesterol, hemoglobulin, uric acid, SGPT, SGOT and H/L ratio in groups T2 and T3 were statistically similar to control diet of broilers. It was concluded that the results showed that no adverse effects on growth performance and blood biochemical parameters in broilers feed with T-2 toxin (50 and 100 ppb) during the entire trial.

Diagnostic Efficiency of Lactate Dehydrogenase, Creatine Kinase and Troponin T in Acute Myocardial Infarction (심근 손상에 있어서 Lactate Dehydrogenase, Creatine Kimase 및 Troponin T 진단적 유용성 비교)

  • Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.1
    • /
    • pp.48-55
    • /
    • 1995
  • The present study was designed to evaluate the efficiency of total lactate dehydrogenase, total creatine kinase, LD1/LD2 ratio, CK-MB and newly developed troponin T in acute myocardial infarction. The level of troponin T was $0.01{\pm}0.02{\mu}g/L$ in 34 healthy person, but the peak vaule of acute myocardial infarction ranged in 4.7-24.2 ${\mu}g/L$. Total lactate dehydrogenase was peaked in 1 to 3 days after chest pain and then progressively decreased, but LD1/LD2 ratio was persistently higher than 1.0 for 10 days in most patients. Total creatine kinase and CK-MB were peaked in 1-2 days, and normalized in 3-4 days, so they were useful in early diagnosis of acute myocardial infarction, but not for the late stages of acute myocardial infarction. Troponin T is early elevated and persistently high level for more than 10 days. Comparing with total lactate dehydrogenase, total creatine kinase, LD1/LD2 ratio and CK-MB, troponin-T test improves the efficiency of serodiagnostic method for the detection of ischemic myocardial damage.

  • PDF