• 제목/요약/키워드: T$_c$ drop

검색결과 96건 처리시간 0.028초

Effect of Pr substitution on the normal-state and superconducting properties of GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$

  • Park, Jung-Rok;Ha, Dong-Han;Lee, Ho-Keum
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.70-75
    • /
    • 2000
  • We report results of a comparative study of the normal-state and superconducting properties in the GdBa$_2$(Cu$_{2.9}$Al$_{0.1}$)O$_z$ system with substitutions by Pr for the Gd and Ba sites. It is observed that, fur both Pr-doped systems, the superconducting transition temperature(T$_c$) decreases almost linearly with the Pr-content, but Pr at Ba sites results in a faster T$_c$ drop than that of Pr at Gd sites. The thermoelectric power measurements indicate that there is a strong correlation between the T$_c$ and the room temperature value of thermoelectric power. The experimental results are discussed in connection with existing models.

  • PDF

증발기 과열도제어에 따른 냉동장치의 동특성에 관한 연구 (A Study on Dynamic Characteristics of a Refrigeration System by Controlling the Evaporator Superheat)

  • 김재돌;오후규;윤정인
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.2012-2021
    • /
    • 1995
  • An experimental study was performed for the analysis of dynamic characteristics of refrigeration system by controlling the evaporator superheat. Experimental data have been taken utilizing two different devices, thermostatic expansion valve(T.E.V.) and electronic expansion valve(E.E.V.), for the control of the evaporator superheat. The ranges of parameters, such as superheat, mass flow rate of refrigerant and inlet temperature of evaporator were 5-30.deg. C 90-170 kg/h and 10-25.deg. C, respectively. The data taken from the T.E.v.and E.E.v.were discussed with the control of the superheat, pressure drop, refrigerating capacity, compression work, evaporating temperature, condensing temperature and COP affecting performance characteristics of refrigeration system. In case of the refrigerant flow control with T.E..V., the superheat and pressure drop of the evaporator varied periodically, but the control with E.E.V., the parameters were very stable. In E.E.v.control, refrigerating capacity, compression work and evaporating temperature were decreased with increasing superheat, and the highest COP was obtained in the range of superheat from 5.deg. C to 15.deg. C.

위상 배열 안테나를 위한 C-대역 CMOS 양방향 T/R 칩셋 (A C-Band CMOS Bi-Directional T/R Chipset for Phased Array Antenna)

  • 한장훈;김정근
    • 한국전자파학회논문지
    • /
    • 제28권7호
    • /
    • pp.571-575
    • /
    • 2017
  • 논문은 $0.13{\mu}m$ TSMC CMOS 공정을 이용한 위상 배열 안테나의 C-대역 양방향 T/R 칩셋에 관한 연구이다. 위상 배열 안테나의 필수 부품인 T/R 칩셋은 6 비트 위상변위기, 6 비트 가변 감쇄기, 양방향 증폭기로 구성하였다. 위상 변위기의 경우 정밀한 빔 조향을 위해서 $5.625^{\circ}$의 간격으로 최대 $354^{\circ}$까지 제어가 가능하며, 측엽 레벨을 제어하기 위한 가변 감쇄기는 0.5 dB 간격으로 최대 31.5 dB까지 감쇄가 가능하다. 또한, 1.2 V의 안정적인 전원공급을 위한 LDO(Low Drop Output) 레귤레이터와 디지털 회로의 제어가 간편하도록 SPI(Serial Peripheral Interface)를 집적화 하였으며, 칩 크기는 패드를 포함하여 $2.5{\times}1.5mm^2$이다.

배전계통 저압배전선 전압강하 추정방법 (Estimation of Voltage Drop in Low Voltage Distribution Line)

  • 김태응;김창순;김재언;손진만;박종근;노대석;김광호;조재형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.118-120
    • /
    • 2002
  • Voltage drop of low voltage distribution line is closely related with proper voltage regulation. It depends on the voltage drop of pole transformer, low voltage distribution line, and low voltage customer entrance line. Using above voltage drop factors, we proposes an estimation method of voltage drop in low voltage distribution line. Proposed method has been applied to a 22.9kV practical distribution system.

  • PDF

시효열화시킨 1Cr-1Mo-0.25V 강의 고온에서의 J$_lc$ 및 T$_mat$ 의 평가 (Evaluation of J$_lc$ and T$_mat$ of aged 1Cr-1Mo-0.25V steel at elevated temperature)

  • 윤기봉;윤석호;서창민;남승훈
    • 대한기계학회논문집
    • /
    • 제18권11호
    • /
    • pp.2860-2870
    • /
    • 1994
  • When crack are detected in aged turbine rotors of power plants, information on fracture resistance of the aged material at operating temperature is needed for determination of critical loading condition and residual life of the turbine. In this study, fracture toughness (J$_lc$) and tearing modulus(T$_mat$) of virgin and thermally degraded 1Cr-1Mo-0.25V steel, which is one of the most widely used rotor steels, were measured at 538.deg. C according to ASTM E813 and ASTM E1152, respectively. Five kinds of specimen with different degradation levels were prepared by isothermal aging heat treatment at $630^{\circ}C.$ It was observed that J$_lc$ and T$_mat$ value decreased as the degradation level increased. Analysis of microstructures using a scanning electron microscope showed that the decrement of J$_lc$ is related to segregation of impurities at grain boundaries. It was also verified that the DC electric potential drop method is accurate and reliable for crack length monitoring at elevated temperature.

Safety assessment of nuclear fuel reprocessing plant under the free drop impact of spent fuel cask and fuel assembly part I: Large-scale model test and finite element model validation

  • Li, Z.C.;Yang, Y.H.;Dong, Z.F.;Huang, T.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2682-2695
    • /
    • 2021
  • This paper aims to evaluate the structural dynamic responses and damage/failure of the nuclear fuel reprocessing plant under the free drop impact of spent fuel cask (SFC) and fuel assembly (FA) during the on-site transportation. At the present Part I of this paper, the large-scale SFC model free drop test and the corresponding numerical simulations are performed. Firstly, a composite target which is composed of the protective structure, i.e., a thin RC plate (representing the inverted U-shaped slab in the loading shaft) and/or an autoclaved aerated concrete (AAC) blocks sacrificial layer, as well as a thick RC plate (representing the bottom slab in the loading shaft) is designed and fabricated. Then, based on the large dropping tower, the free drop test of large-scale SFC model with the mass of 3 t is carried out from the height of 7 m-11 m. It indicates that the bottom slab in the loading shaft could not resist the free drop impact of SFC. The composite protective structure can effectively reduce the damage and vibrations of the bottom slab, and the inverted U-shaped slab could relieve the damage of the AAC blocks layer dramatically. Furthermore, based on the finite element (FE) program LS-DYNA, the corresponding refined numerical simulations are performed. By comparing the experimental and numerical damage and vibration accelerations of the composite structures, the present adopted numerical algorithms, constitutive models and parameters are validated, which will be applied in the further assessment of drop impact effects of full-scale SFC and FA on prototype nuclear fuel reprocessing plant in the next Part II of this paper.

자기장하의 액체금속 유동의 차압 측정 (MHD Pressure Drop of a Liquid-Metal Flow under a Transverse Magnetic Field)

  • 차재은;김희령;김종만;남호윤;김성오;김병호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2638-2641
    • /
    • 2007
  • The magnetohydrodynamic(MHD) pressure drop along a liquid sodium flow was measured in a rectangular duct under a transverse magnetic field. The test section was made of a 3 mm thick stainless steel SUS304 with a $74{\times}5mm^2$ rectangular flow channel. The range of experimental parameters was roughly B=0${\sim}$0.18T and U=0${\sim}$0.9m/s at around $200^{\circ}C$. The differential pressure was measured by a diaphragm seal-type pressure transmitter filled with a high temperature silicon oil within 0.1MPa. The experimental results show a similar pressure drop with the theoretical estimation according to a change of the flow velocity and the magnetic field.

  • PDF

평행평판의 전극형상에 따른 ER 유체의 유동특성 I (The Flow Characteristics of ER Fluids According to the Electrode Shape of Two Parallel-Plate)

  • 장성철;염만오;김도태;김태형;배태열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.207-212
    • /
    • 2001
  • Electro-Rheological(ER) fluid are suspensions which show an abrupt increase in rheological properties under electric fields. ER effects arise from electrostatic forces between the starch particles dispersed in the electrically insulating silicone oil, induced when an electric field is applied. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields. This paper presents performance analyses of four types of the two parallel-plate. Which have different electrode length and width but same electrode area. On the basis of the pressure drop and flow rate analysis. Four types of the two parallel-plate are designed and manufactured. Using ER fluid, it is possible to directly interface between electric signals and fluid power without moving parts.

  • PDF

냉매의 불균일한 분배가 증발기의 성능에 미치는 영향 (Effects on Refrigerant Maldistribution on the Performance of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.230-240
    • /
    • 2004
  • An experimental investigation was conducted to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R22. A comparison was made between the predictions by previously proposed tube-by-tube method and experimental data for the heat transfer rate of evaporator. Experiments were carried out under the conditions of saturation temperature of 5$^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of 27$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71㎧. Experiment show that air velocity increased by 85.2% is need for T-type distributor with four outlet branches than that of two outlet branches under the superheat of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 130% for T-type distributor with four outlet branches as compared to two outlet branches.

고순도 Polymer 방사기계 필터 시스템 최적설계 기술 개발에 관한 실험적 연구 (A Experimental Study of Optimum Filter System Design of High Purity Polymer Thread Machine)

  • 오태훈;김창식;송동주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.514-519
    • /
    • 2000
  • Predicting a pressure drop between inlet and outlet of the filter system is essential in designing the optimum filter system. This experiment has been carried out to investigate several design parameters which influence in a pressure drop, such as different tube length and metal fiber filter mesh size. A 1/50 scale filter system was made to simulate a real filter system. Results are compared with Darcy equation for a porous media.

  • PDF