• Title/Summary/Keyword: Systolic velocity

Search Result 103, Processing Time 0.035 seconds

Clinical Study of Blood Flow Velocity Using Transcranial Doppler Ultrasound on Cerebral Arteries in Dizziness Patients (경두개 도플러 초음파를 이용한 현훈 환자의 뇌혈관 혈류 측정에 관한 임상적 연구 (중대뇌동맥, 추골동맥 및 기저동맥을 중심으로))

  • Kim, Bong-Suk;Oh, Jung-Han;Kim, Dong-Woo;Choi, Bin-Hye;Jang, Woo-Seok;Seo, Young-Ho;Son, Dae-Yong;Byun, Joon-Seok;Lim, Hee-Yong
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.418-426
    • /
    • 2004
  • Objectives : This study was designed to research whether transcranial doppler ultrasound(TCD) can yield a suitable diagnosis or prognosis for dizziness. Methods : To evaluate the blood flow, we measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of the middle cerebral artery(MCA), vertebral artery(VA) and basilar artery(BA) in 54 dizziness patients and 44 normal subjects. To investigate the difference between dizziness patients and normal subjects, we selected 54 dizziness patients diagnosed normal by Brain MRI, and 44 normal subjects who did not have any symptoms of hyperlipemia, hypertension, diabetes melitus, heart disease, or smoking, diagnosed normal by Brain MRI. 30-69 year olds were divided into 30-49 year olds, 50-59 year olds and 60-69 year olds. Results : In normal subjects, there was a significantly higher Vm, Vs in the MCA and BA, and Vs in the VA of female subjects, and there was a significant difference in PI in the MCA and BA increasing with age. In comparison with normal subjects, dizziness patients had a significantly lower Vm in the BA. Male dizziness patients had significantly lower PI in the MCA. 30-49 year olds had significantly lower Vm in the BA. Conclusions : The significant difference in blood flow velocities in the BA between dizziness patients and normal subjects suggests that dizziness is related to blocking of blood flow in the BA and that diagnosis and prognosis can be made through TCD. More detailed study of dizziness patients will be needed.

  • PDF

Imaging Diagnosis of Dilated Cardiomyopathy in a Maltese Dog

  • An, Soyon;Park, Junghyun;Mok, Jinsu;Kim, Areum;Han, Changhee;Song, Joong Hyun;Yu, Dohyeon;Hwang, Tae Sung;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.163-168
    • /
    • 2021
  • A 6-year-old, spayed female, Maltese dog with tachypnea and dry cough was presented to Gyeongsang National University Veterinary Medical Teaching hospital. On physical examination, its respiration rate was 132 per minute. Decreased partial pressure of oxygen, partial pressure of carbon dioxide, and hyperlactatemia were found on arterial blood gas analysis. Its diastolic blood pressure was 80 mmHg. Auscultation revealed arrhythmia. Electrocardiogram revealed P pulmonale, P mitrale, and ventricular premature complexes. Thoracic radiographs revealed mild enlargement of both atrium and moderate enlargement of the left ventricular. There was also a moderate alveolar pattern in the right and caudal part of the left cranial lung lobe. Two-dimensional echocardiography showed enlargement of generalized four chambers without remarkable findings of valvular degeneration. M-mode echocardiography showed decreased left ventricular fractional shortening and enlarged left ventricular internal diameter at both end-systolic and end-diastolic. Color-flow Doppler imaging revealed eccentric turbulent flow starting below the left ventricular outflow tract and extending into the left atrium during systole. Spectral Doppler recordings revealed a high velocity flow through the mitral, tricuspid, aorta, and pulmonic regurgitation. Restrictive transmitral flow revealed high E-wave velocity, short E-wave deceleration time, and reduced A-wave velocity. There was also low ejection velocity thorough left ventricular out tract flow. Based on echocardiographic examination, dilated cardiomyopathy was the tentative diagnosis. The dog was medicated with inotropes, angiotensin converting enzyme inhibitor, and diuretics. At the 10-day following-up, the dog died suddenly. This report describes echocardiographic diagnosis and prognosis of dilated cardiomyopathy rarely reported in small breed dogs.

Analysis of Changes in Carotid Intima-media Thicknesses according to Metabolic Syndrome-inducing Factors (대사증후군 유발 인자에 따른 경동맥 내중막 두께의 변화 분석)

  • Nan-Hee An;Tae-Jeong Ji;Hyeon-Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.597-606
    • /
    • 2023
  • This study retrospectively analyzed the test results of 235 patients who visited a medical institution in Busan from May 2022 and February 2023 and conducted both carotid ultrasonography and blood tests. The purpose of this study was to investigate the effect on intima-media thickness and blood flow velocity by measuring the intima-media thickness and blood flow velocity through carotid ultrasonography and analyzing the factors influencing the subject's body mass index and metabolic syndrome. Correlation analysis between carotid intima-media thickness and body mass showed (p=0.000) confirming that there is a correlation. As a result Correlation analysis between blood flow velocity and body mass index (p=0.015) was found, comfirming that there was a correlation. Age (p= 0.000), fasting blood glucose (p=0.002) and alcohol consumption (p=0.006) were found to be correlated with carotid intima-media thickness. An increase in Carotid intima-media thicknesses causes an increase in events caused by cardiovascular disease. Therefore, efforts must be made to exclude factors that increase Carotid intima-media thicknesses, and it will be most important to prevent cardiovascular disease through research on various prediction methods and regular checkups.

Effects of stenotic severity on the flow structure in a circular channel under a pulsatile flow

  • Kim, Kyung-Won;Cheema, Taqi-Ahmad;Park, Cheol-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.140-146
    • /
    • 2014
  • Stenosis is the drastic reduction in the cross-sectional area of blood vessel caused by accumulations of cholesterol. It affects the blood flow property and structure from the fluid dynamic point of view. To understand the flow phenomenon more clearly, a particle image velocimetry method is used and the fluid dynamic characteristics in a circular channel containing stenosis structure is investigated experimentally in this study. Different stenotic-structured models made of acrylic material are subjected to a pulsatile flow generated by an in-house designed pulsatile pump. The inner diameter of the tube inlet is 20 mm and the length of reduced area for stenosis ranges between 35mm and 40mm. It is circulated continuously through a circular channel by the pump system. Pressure is measured at four different sections during systolic and diastolic phase changes. The phase-averaged velocity field distribution shows a recirculation regime after the stenotic structure. The effects of the stenotic obstructions are found to be more severe when the aspect ratio is varied.

Effects of Foot Reflexo-massage on Physical, Psychological, Physiological Parameters in Patients with Osteoarthritis (발반사마사지가 골관절염 환자의 신체적, 심리적, 생리적 지수에 미치는 영향)

  • Uhm, Dong-choon
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.2
    • /
    • pp.276-287
    • /
    • 2004
  • Purpose: This study was undertaken to investigate the effects of foot reflexo-massage on physical, psychological, and physiological parameters in patients with osteoarthritis of the knee. Method: This study was employed non-equivalent control group pretest-posttest time series experimental design. The subjects of this study were 47 elderly patients with osteoarthritis of the knee from two different nursing homes in Deajeon. The patients were divided into two groups; 26 patients in experimental group, the rest in control group. Each patient in experimental group received the 30-minute foot reflexo-massage, 3 times per week for 4 weeks. The dependent variables of each patient were measured before treatment, after 2 weeks and after 4 weeks during the treatment session. The collected data was analyzed using the Social Package Social Science(version 10.0) software program. Result: There were significant differences in the flexion angle of both knees; the flexion and extension muscle strength of both knees; systolic blood pressure; POMS; plantaris skin temperature and blood velocity of dorsalis pedis artery between the two groups over different the three measurement times. Conclusion: The results suggest that foot reflexo-massage could be an effective intervention to improve physical, psychological and physiological parameters for patients with knee osteoarthritis.

  • PDF

Echocardiographic Diagnosis of Subaortic Stenosis with Severe Deformation of Mitral Valve Apparatus in a Dog

  • Chung, Doo-ri;Yoon, Young-min;Hwang, Tae-sung;Choi, Moon-yeong;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.54-57
    • /
    • 2017
  • A 1-year-old castrated male Schnauzer dog was presented with heart murmur. Auscultation revealed systolic murmur located at the left heart base (grade 5/6). There were no remarkable findings on thoracic radiographs. Two-dimensional echocardiography revealed subaortic tunnel-like obstruction at the entrance to the left ventricular outflow tract. Anterior mitral valve leaflet appeared to be tethered to septum with minimal motion. Chordae tendineae was abnormally thickened. Color Doppler analysis revealed turbulent flow starting below the aortic valve. Mitral regurgitation was presented during systole. Spectral Doppler recordings revealed high velocity flow through the aorta and mitral regurgitation. Based on echocardiographic examination, the dog was diagnosed with subaortic stenosis concurrent with mitral dysplasia. The patient was medicated with ${\beta}-blocker$ and diuretics. It has been doing well without apparent clinical signs at 2 year after the diagnosis.

Diffusion Tensor Imaging and Cerebrospinal Fluid Flow Study of Cine Phase Contrast in Normal Cervical Spinal Cords (정상인 경수에 대한 확산텐서영상과 PC기법을 이용한 뇌척수액 속도 측정에 관한 연구)

  • Son, B.K.;Kwak, S.Y.;Han, Y.H.;Yoo, J.S.;Kim, O.H.;Ko, H.Y.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • Purpose : We report the results of the various parameters of diffusion tensor imaging (DTI) and CSF flow study of the cervical spinal cord using magnetic resonance (MR) imaging techniques. Materials and Methods: Intramedullary FA and MD were measured in the gray matter and posterior cord of the white matter and both lateral cords of the white matter at the C2-3, C4-5, C5-6 spinal levels. For the CSF flow study, velocity encoding was obtained at the C2-3, C4-5, C5-6 spinal levels. Results: There was a significant difference of the FA and MD between the white matter and gray matter (p < 0.05). The FA of the gray matter was significantly different according to the cervical spinal cord levels (p < 0.05). Otherwise, the FA and MD parameters were not significantly different (p > 0.05). The mean peak systolic velocity and mean peak diastolic velocity were $5.18{\pm}2.00cm/sec$ and $-7.32{\pm}3.18cm/sec$, respectively from C2 to C6 spinal cords. There was no significant difference in these velocities among the cervical spinal cord (p > 0.05). Conclusion: This basic information about DTI and CSF dynamics of the cervical spinal cord may be useful for assessing cervical spinal cord abnormalities using MR imaging.

Cerebral Blood Flow as Measured by TCD in Hyperlipidemic Group (TCD를 이용한 정상군과 고지혈증군의 혈류측정에 관한 비교연구)

  • Park, Sun-Mi;Kim, Young-Kyun;Kwon, Jung-Nam;Shin, Woo-Jin;Son, Yeon-Hui;Jeong, Hyun-Yun;Han, Hyun-Young;Park, Ga-Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1513-1520
    • /
    • 2009
  • The purpose of this study was to compare cerebral blood flow between hyperlipidemic patient group and normal healthy aldult group using transcranial doppler ultrasonography(TCD). I investigated cerebral blood flow of 63 hyperlipidemic patients and 42 healthy adults. To evaluate the cerebral blood flow, I measured the systolic peak velocity(Vs) and mean flow velocity(Vm) of the milddle cerebral artery(MCA), anterior cerebral artery(ACA), posterior cerebral artery(PCA), basilar artery(BA), internal carotid artery(ICA) in the two groups using TCD. In normal healthy adults, subjects showed a decerease in Vs and Vm with advancing in age. There was a significant difference in the Vm of ICA. There was no significant differences in the Vm of ACA and ICA. In normal healthy adults, females showed high velocities of all examined vessel. There was a significant difference in the Vs of ICA. There was a significant differences in the Vm of MCA and ICA. Normal healthy adults higher than hyperlipidemic patients in the Vs of MCA, ACA, PCA. There was no significant difference in the Vs of all exmined vessels. Hyperlipidemic patientsincrease higher than normal healthy adults in the Vm of ACA. There was a significant difference in the Vs of BA. In the patients aged under 50's, normal healthy adults higher than hyperlipidemic patients in the Vs and Vm except BA. But there was no significant difference in all exmined vessels. In the patients aged over 50's, hyperlipidemic patients higher than normal healthy adults in all examined vessel expect PCA. There was a significant difference in the Vs of BA and ICA. And hyperlipidemic patients higher than that normal healthy adults in all exmined vessels. There was a significant difference in BA and ICA. In this study, visible differences in blood flow between hyperlipidemic patient group and normal healthy aldult group were shown. However, these results do not come up to the previous values that were reported and known worldwide.

Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound (대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰)

  • Um, Eun-Jin;Park, Woo-Rham;Kim, Ju-Sung;Lee, Beom-Joon;Na, Byung-Jo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.

Gender Differences in Physiological Effects of a Transient Exposure to Experimental Noise

  • Hyun, Kyung-Yae;Kim, Chong-Rak;Kim, Hwa-Il;Kim, Young-Hwal;Choi, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.375-383
    • /
    • 2006
  • The physiological responses following stress are different in individual or personality. We performed this study to clarify gender differences in influences of noise stress on physiological factors. 70 healthy subjects, which was divided man (n=30) and woman (n=40) groups, were exposed to 85 decibels of excavator noise for 15 minutes. Cardiac factors such as heart rate (HR), systolic and diastolic blood pressures (SBP and DBP, respectively), and heart rate-systolic pressure product (RPP) were determined. Transcranial Doppler ultrasound (TCD) was used to measure mean blood flow velocity (Vm), pulsatility index (PI), and resistance index (RI) in the middle, anterior and posterior cerebral arteries (MCA, ACA and PCA, respectively) before and during noise exposure. Cortisol level and hematological variables were also measured before (baseline) and immediately after the end of noise exposure. In the both groups HR, SBP, and RPP significantly decreased during noise exposure (P<0.05) but not significantly different between two groups (P>0.05). Vms of three cerebral arteries in man group decreased, whereas Vm of PCA in woman group fell during noise exposure (P<0.05). Vm, PI and RI in MCA and ACA during noise exposure were low in man group compared with woman group (P<0.05). Vm of PCA was low, whereas PI and RI of PCA were high in man group compared with woman group during noise exposure (P<0.05). Total leukocyte and red blood cell (RBC) counts slightly decreased during noise exposure but not significant (P>0.05). Levels in hematological variables decreased but not significant changed following noise exposure. Decreased rate of total leukocyte in man group was higher (P<0.05). Cortisol levels in the both groups decreased immediately after the end of noise exposure, while the decreased rate in man group was greater than that in woman group (p<0.05). These findings indicate that a transient exposure to experimental excavator noise may cause decreased changes in cardiac factors, cerebral hemodynamics and cortisol levels and the changes may be greater in men than in women.

  • PDF