• Title/Summary/Keyword: Systolic pressure

Search Result 1,580, Processing Time 0.028 seconds

A Study on the Circadian Blood Pressure Rhythm of Diabetic Patients (당뇨병 환자의 혈압 일주기 리듬에 관한 조사연구)

  • 김화순;서화숙
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.3
    • /
    • pp.741-749
    • /
    • 2000
  • This study was performed to investigate the relationship between reversed circadian blood pressure and risk factors of peripheral vascular disease in non-insulin-dependent diabetes mellitus (NIDDM) subjects. The subjects in this study were 18 NIDDM patients who were hospitalized in a medical unit of an university medical center located in Incheon, Korea, between November, 1998 and March, 1999. Blood pressure was measured with a mercury sphygmomanometer by 2 trained examiners every 2 hours during 24 hours. NIDDM subjects were divided into a dipper group and non-dipper group. Dippers are defined as those who show a mean nighttime blood pressure(BP) drop of more than 10% compared with daytime BP. Non-dippers are defined as those who show a mean nighttime BP drop of less than 10%, or an elevation in BP compared with daytime BP. Daytime BP included values obtained between 6 a.m. and 10 p.m. Night time BP included values obtained between 10 p.m. and 6 a.m. Data was analyzed by SPSS/PC package. Chi-square( $^2$) test was used for the comparison of sex between The dipper group and non-dipper group. Mann-Whitney test was used for comparisons of values of the risk factors of peripheral vascular disease and the frequency of complications of diabetes between the dipper group and non-dipper group. The results are as follows. There were no significant differences in daytime systolic, diastolic, and mean blood pressures between the dipper group and non-dipper group. However, night time systolic, diastolic, and mean blood pressures in the non-dipper group were significantly nigher than those in the dipper group (p=.021). There were no differences in sex, age, body, weight, duration of diabetes, serum lipid levels, BUN and HbA1c between the two groups. On the contrary, 87.5% of non-dipper group subjects showed having hypertension, 30% of dipper group subjects showed having hypertension and this difference was statistically significant (p=.018). All of the non-dipper group subjects (N=8) showed having at least one diabetic complication. However, 40% of the dipper group subjects (N=10) showed having no diabetic complication at all and this difference was also statistically significant (p=.049). There were no significant differences in frequency of nephropathy, neuropathy and retinopathy between the dipper group and non-dipper group.

  • PDF

Factors Related to Self-care Behavior and the Control of Hypertension in the Low-income Elderly (저소득층 고혈압노인의 자가간호행위 및 혈압조절에 관련된 요인)

  • Choi, Young-Soon;Kim, Hyun-Li
    • Research in Community and Public Health Nursing
    • /
    • v.17 no.4
    • /
    • pp.441-450
    • /
    • 2006
  • Purpose: The purposes of this study were to identify variables related to self-care behavior and to find factors related to the control of hypertension. A cross-sectional study was carried out to provide basic data for effective and continuous hypertension control in the low-income elderly. Methods: This study was performed with a total of 189 subjects who were hypertensive and were receiving pharmacological treatment of hypertension from a community health center in D Metropolitan City. Data were collected through a face to face survey, and systolic and diastolic blood pressure (the mean value of the two measures) were measured during May 2004. Obtained data were analyzed by $x^2$ test, t-test, multiple logistic regression and Pearson's correlation coefficient (using SPSS Version 10.1). Results: 1. According to demographical characteristics, the score of self-care behavior was significantly higher in elders living along ($47.63{\pm}7.276$) than in those living with the family ($45.19{\pm}5.501$) (p<.05), and in those with religion ($47.11{\pm}6.722$) than in those without religion ($45.01{\pm}6.110$) (p<.05) 2. As to blood pressure control, the percentage of blood pressure control within the normal range (systolic 140mmHg, diastolic below 90mmHg) was 37.03%. According to demographical characteristics, the percentage of blood pressure control was significantly lower in those without religion (p<.05). In practicing hypertension self-care behavior, those who do not control salk intake showed a significantly lower percentage of hypertension control (p<.05). The score of hypertension self-care was $48.28{\pm}4.443$ in the controlled group, and $45.42{\pm}7.399$ in the uncontrolled group, showing a significant difference (p<.01). 3. Hypertension self-care behavior was in a positive correlation with blood pressure control (r=.210, p<.05). Conclusion: Attention should be paid to self-care behavior to increase the control of hypertension in the low-income elderly. These results can be used guidances for improving self-care behavior and the control of hypertension in the low-income elderly.

  • PDF

Simulation of the Blood Pressure Estimation Using the Artery Compliance Model and Pulsation Waveform Model

  • Jeon, Ahyoung;Ro, Junghoon;Kim, Jaehyung;Baik, Seongwan;Jeon, Gyerok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, the artery's compliance model and the pulsation waveform model was proposed to estimate blood pressure without applying HPF (High Pass Filter) on signal measured by the oscillometric method. The method proposed in the study considered two ways of estimating blood pressure. The first method of estimating blood pressure is by comparing and analyzing changes in pulsation waveform's dicrotic notch region during each cardiac period. The second method is by comparing and analyzing morphological changes in the pulsation waveform during each cardiac period, which occur in response to the change in pressure applied on the cuff. To implement these methods, we proposed the compliance model and the pulsation waveform model of the artery based on hemodynamic theory, and then conducted various simulations. The artery model presented in this study only took artery's compliance into account. Then, a pulsation waveform model was suggested, which uses characteristic changes in the pulsation waveform to estimate blood pressure. In addition, characteristic changes were observed in arterial volume by applying artery's pulsation waveform to the compliance model. The pulsation waveform model was suggested to estimate blood pressure using characteristic changes of the pulsation waveform in the arteries. This model was composed of the sum of sine waves and a Fourier's series in combination form up to 10th harmonics components of the sinusoidal waveform. Then characteristic of arterial volume change was observed by inputting pulsation waveform into the compliance model. The characteristic changes were also observed in the pulsation waveform by mapping the arterial volume change in accordance with applied cuff's pressure change to the pulsation waveform's change according to applied pressure changes by cuff. The systolic and diastolic blood pressures were estimated by applying positional change of pulsation waveform's dicrotic notch region.

Replicated Association between SLC4A4 Gene and Blood Pressure Traits in the Korean Population

  • Jin, Hyun-Seok;Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.18 no.4
    • /
    • pp.377-383
    • /
    • 2012
  • Recent genome-wide association studies (GWAS) have identified a number of common variants associated with blood pressure homeostasis and hypertension in population. In the previous study, single nucleotide polymorphisms (SNPs) in the SLC4A4 gene have been reported to be associated with hypertension in Han Chinese population. We aimed to confirm whether the genetic variation of SLC4A4 gene influence the susceptibility to blood pressure and hypertension in Korean population. We genotyped variants in or near SLC4A4 in a population-based cohort including 7,551 unrelated Korean from Ansan and Ansung. Here, we performed association analysis to elucidate the possible relations of genetic polymorphisms in SLC4A4 gene with blood pressure traits. By examining genotype data of a total of 7,551 subjects in the Korean Association REsource (KARE) study, we discovered the SLC4A4 gene polymorphisms are associated with blood pressure and hypertension. The common and highest significant polymorphism was rs6846301 (${\beta}$=0.839, additive P=0.032) with systolic blood pressure (SBP), rs6846301 (${\beta}$=0.588, additive P=0.027) with diastolic blood pressure (DBP), and rs6846301 (OR=1.23, CI: 1.09~1.40, additive $P=1.2{\times}10^{-3}$) with hypertension. Furthermore, the SNP rs6846301 was consistently associated with both blood pressure and hypertension. Consequently, we found statistically significant SNPs in SLC4A4 gene that are associated with both blood pressure and hypertension traits. In addition, these results suggest that the individuals with the minor alleles of the SNP in the SLC4A4 gene may be more susceptible to the development of hypertension in the Korean population.

A Study for Changes of Blood Pressure and Heart Rate by Acupressure to Acupoints in Rat Model of Hemorrhagic Shock (출혈성 쇼크 흰쥐 모델에서 경혈 지압이 혈압과 심박수 변화에 미치는 영향)

  • Yang, Seung-Bum;Byun, Sin-Kyu;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.33 no.2
    • /
    • pp.58-66
    • /
    • 2016
  • Objectives : In order to find a possible non-invasive manipulation tool for maintenance of the cardiovascular functions in hemorrhagic shock, this study was aimed at evaluating effects of acupoints acupressure on the changes in blood pressure and heart rate from an animal model of hemorrhagic shock. Methods : In adult Sprague-Dawley rats, hemorrhagic shock was induced by a withdrawal of arterial blood from the femoral artery with volume of 0.8 ml per 100 g of body weight using peristaltic syringe pump. We applied the acupressure with a pressure oscillator to tail as a control and 2 different acupoints of sobu(HT8), youngchun(KI1) under 3 different conditions : 1) normal arterial blood pressure without bleeding, 2) at the beginning of bleeding, and finally 3) hemorrhagic shock. Results : Under normal arterial blood pressure without hemorrhage, there was a significant increase in systolic and diastolic blood pressures by the acupressure to the tail, HT8 and especially KI1 for 30 sec compared with before acupressure. Under hemorrhagic shock condition, the tail acupressure had minimal changes in cardiovascular parameters. Either the HT8 or KI1 acupressure resulted in a significant increase in arterial pressure but did not heart rate. At the beginning of bleeding, tail acupressure failed to change the reduction of arterial pressure and heart rate. However, there was a significant increase in blood pressure and heart rate following either the HT8 or especially KI1 acupressure. Conclusions : HT8 and KI1 acupressure affected cardiovascular signs but tail acupressure did not in rat model of hemorrhagic shock. These experimental data suggest that a acupressure with a pressure oscillator to HT8 or KI1 can be one of alternative emergency manipulations to ameliorate compromised cardiovascular functions under hemorrhagic shock condition.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

The Relationship between Stress and pain in patient Undergoing Angiocardiography (심혈관조영술 환자의 스트레스와 통증과의 관계)

  • Kwon, Kyung-Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.4
    • /
    • pp.317-324
    • /
    • 2004
  • The purpose of this study was to provide basic data for nursing intervention in patient undergoing angiocardiography. Method: The subjects of this study were 60 patients undergoing angiocardiography. The data were analyzed using mean, percentage and pearson correlation Coefficient. Result 1) The mean score of the affective stress(anxiety) was $48.00{\pm}12.24$ and behavioral stress was $1.98{\pm}1.97$. The mean score of the physiologic stress(vital sign) was systolic pressure $124.10{\pm}17.72$, diastolic pressure $79.71{\pm}12.68$, pulse: $81.03{\pm}12.16$, respiration: $21.21{\pm}1.40$ 2) The mean score of the pain was $1.40{\pm}0.67.$ 3) There was a significant positive correlation between stress and pain. Conclusion : The result of this study show that stress is very important factor that effect on the pain therefore it will be considered stress in patient undergoing angiocardiography.

  • PDF

The Effects of Transcutaneous Electrical Nerve Stimulation on Sympathetic Nerve Activity in Delayed Onset Muscle Soreness (경피신경전기자극이 지연성근육통의 교감신경활동에 미치는 영향)

  • Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.109-115
    • /
    • 2002
  • This study conducts eccentric exercise ti non-dominant elbow flexor of 20 persons in order to examine the effects of transcutaneous electric nerve stimulation on sympathetic nerve activity in delayed onset muscle soreness, induces delayed onset muscle soreness, divides them into 10 persons respectively as experimental and control groups. And a stimulation for 2 min. with 100 pps is given to elbow flexor after repeated three times of 10 minutes rest, temperature, blood pressure and pulse are measured and as a result of two-way ANOVA, change of temperature didn't show a significant difference according to the elapse of times(p>0.05) and systolic pressure and pulses in showed a significant difference between experimental and control groups(p<0.05). These results suggest that transcutaneous electrical nerve stimulation has a direct or indirect influence on sympathetic nerve activity in delayed onset muscle soreness under a restricted condition of electrical stimulation.

  • PDF

Surgical Correction of Pulmonary Atresia with VSD -Report of a Case- (심실 중격 결손증을 동반한 폐동맥 폐쇄증의 외과적 교정)

  • 김대영
    • Journal of Chest Surgery
    • /
    • v.28 no.11
    • /
    • pp.1045-1048
    • /
    • 1995
  • Pulmonary atresia with VSD is uncommon congenital anomaly with high mortality in neonatal period.Recently we experienced surgical correction of pulmonary atresia with VSD. The case was 2 month old male patient diagnosed as pulmonary atresia with VSD and PDA. Atretic pulmonary artery segment from Rt ventricular infundibulum to pulmonary artery was lcm in length. The pulmonary trunk tapered toward Right ventricular infundibulum and resulted in blind pouch with diameter of lmm. The left pulmonary artery was stenosed at just proximal and distal part to which PDA was connected. Total correction was undertaken which consisted of PDA ligation, dacron patch closure of VSD, establishment of continuity between right ventricle and pulmonary artery with autogenous pericardium. Postoperative systolic fight ventricular pressure and left ventricular pressure ratio was 0.7. In patient with pulmonary atresia with VSD it is advisable to perform a corrective operation, whenever the size and anatomy of pulmonary artery are acceptable for it.

  • PDF