• 제목/요약/키워드: System-frequency

검색결과 17,658건 처리시간 0.047초

태양광 연계 계통의 주파수 보호 기준 정립 (The Frequency Protection of Distribution System with Photovoltaic System)

  • 서훈철;김철환;윤영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

765kV 모델링 데이터에 의한 개선된 주파수 추정기법의 성능 평가 (Performance Evaluation of Advanced Frequency Estimation Technique using 765kV Modeling Data)

  • 박철원
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.253-257
    • /
    • 2010
  • The frequency is an important operation parameter for the control, protection, and stability of a power system. The frequency as a key index of power quality can be indicative of system abnormal conditions and disturbances. Due to the sudden change in generation and loads or faults in power system, the frequency is supposed to deviate from its nominal value. It is essential that the frequency must be maintained very close to its nominal frequency. An accurate monitoring of the power frequency is essential to optimal operation and prevention for wide area blackout. As most conventional frequency estimation schemes are based on DFT filter, it has been pointed out that the gain error could cause defects when the frequency is deviated from nominal value. This paper presents an advanced frequency estimation technique using gain compensation to improve the performance of DFT filter based techniques. To evaluate performance of the proposed algorithm, the 765kV T/L system in Korea is simulated by EMTP-RV software. The proposed technique can reduce the gain error caused when the power system frequency deviates from nominal value.

FIR 필터를 이용한 전력계통 주파수 추정기법에 관한 연구 (A Study on the Estimation Technique of Frequency in the Power System using FIR Filter)

  • 남시복;이훈구;박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.80-85
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Frequency of a power system remains constant if sum of all the loads plus losses equals total generation in the system. However, the frequency starts to decrease if total generation is less than the sum of loads and tosses. On the other hand, the system frequency increases if total generation exceeds the sum of loads and losses. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR(finite duration impulse response) filter, a phase angle of a voltage. The rate change of the phase angle is used for estimation and speed in its process. Also, to confirm the validity of the proposed algorithm, the simulation results obtained by using EMTP(electro magnetic transients program) are shown.

  • PDF

통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계 (High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy)

  • 박철원;원철희
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

평판 유도발열체의 거리·주파수 가변특성에 관한 연구 (A study on the Distance and Frequency Variable Characteristics of Flat Plate Induction Heating Element)

  • 우형균;신대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.68-74
    • /
    • 2013
  • Induction-heated system is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. This technique is used high frequency inverter. By using high frequency inverter high frequency in the range of kHz can be made with conventional alternative current. In this contribution IGBT module is used for high frequency inverter. In this paper are discussed analysis of characteristics according to the each frequency and produced Flat plate induction heating system using 1.5kW-class half-bridge resonant inverter. In addition, operating characteristics of the system to changes in the distance between the coil and the heater, applications of system are also discussed.

고주파 유압시스템에서 감치장치와 축압기에 의한 맥동 충격파 감쇄특성에 대한 연구 (Research for the Pulsating Pressure Characteristics by a Damper and an Accumulator in the High Frequency Hydraulic System)

  • 김양수;김재수;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.641-647
    • /
    • 2004
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. The accumulator in high frequency hydraulic system but that is not effective all frequency zone. Therefore, a hydraulic damper used with accumulator is suggested to reduce the high frequency pulsatile where the accumulator is not effective. The pulsating pressure obtained by Pressure measurement system are analyzed to power spectral density distribution. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator or pulsatile damper The amplitude of pressure with damper is very lower than those without accumulator or damper due to absorbing function of damper. As the frequency of actuator acceleration is increased, the effect of damper becomes very important to decrease the amplitude of pulsatile Pressure waveform with high frequencies.

  • PDF

FIR 필터를 이용한 전력계통의 주파수 추정기법 (Estimation Technique of Frequency using FIR Filter in the Power System)

  • 남시복;박철원;신명철
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

동적부하차단 모델을 이용한 KEPCO 계통의 주파수 해석 (Frequency Analysis on KEPCO Power System Using Dynamic Load Shedding Model)

  • 장병태;이소영;김경호;추진부;오화진;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.121-122
    • /
    • 2002
  • When a power system experiences a serious disturbance on insufficient power, the system frequency may drop. For system frequency will be maintain standard value, under_frequency relay will reconstruct balance of power and load by load shedding. Currently load shedding scheme is due to establishment plan by fixed scenario. Where compare current scheme with past scheme, system frequency should be recovered by load shedding using rate of frequency decline. This paper suggests the dynamic load shedding scheme by using the rate of change of frequency when The Korea Electric power system is happened the large disturbance.

  • PDF

주파수역에서의 피드백시스템의 성능향상을 위한 제어기 Atuo-tuning 기법 (Controller Auto-tuning Scheme for Improving Feedback System Performance in Frequency Domain)

  • 정유철;이건복
    • 한국공작기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.26-30
    • /
    • 2001
  • Controller refinement scheme to improve the performance of a conventional system automatically in frequency domain is proposed. The controller automatic tuning method features using experimental frequency responses of the conventional closed-loop system, the conventional controller, and the improved closed-loop system, instead of poorly modeled plant due to non-linearities and disturbances. The improved closed-loop system characteristics is automatically acquired by the con-ventional closed-loop system characteristics and the proposed performance index in system bandwidth. And the proper controller is realized by least squares approximation in frequency domain. To testify the usefulness of the approach, the path tracking control of robot arm is performed. Experimental results and analytic results are well-matched.

  • PDF