• Title/Summary/Keyword: System technique

Search Result 17,284, Processing Time 0.044 seconds

A Practical Voltage Error Correction Technique for Distribution System under Distribution Automation Environment

  • Aslam, Muhammad;Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.669-676
    • /
    • 2018
  • Transmission system has been well studied since long time and power system techniques of distribution system are more or less derived from transmission system. However, unlike transmission systems, many practical issues are encountered in the distribution system. Considerable amount of error is observed in voltage obtained from the Feeder Remote Terminal Units (FRTUs) measured by the pole mounted PTs along the distribution feeder. Load uncertainty is also an issue in distribution system. Further, penetration of Distributed Generators (DGs) creates voltage variations in the system. Hybrid radial/ loop distribution system also make it complicated to handle distribution system. How these constraints to be handled under Distribution Automation (DAS) environment in order to obtain error free voltage is described in this paper and therefore, a new approach of voltage error correction technique has been proposed. The proposed technique utilizes reliable data from substation and the FRTUs installed in DAS. The proposed technique adopts an iterative process for voltage error correction. It has been tested and proved accurate not only for conventional radial systems but also for loop distribution systems.

A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM (Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가)

  • Shin, Jung-In;Kum, Kee-Yeon;Lee, Sung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

Performance Analysis or MC / DS CDMA System with Hybrid SC / MRC Diversity over Multi-path Fading Channels (다중경로 페이딩 채널에서 Hybrid SC/MRC 기법이 적용된 MC / DS CDMA 시스템의 성능분석)

  • 김원섭;박진수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7A
    • /
    • pp.748-755
    • /
    • 2004
  • In this paper, the hybrid SC/MRC technique was applied to the MC/DS-CDMA system in the Nakagami-m multi-path fading environment. The applied scheme was compared with other cases when the MRC technique was applied and then performances were analyzed. The result of analysis showed that the performance of the applied system, whose number of branches (L) for the input diversity of each carrier wave was 3 and かme selected number of branches ( Lc) was 2, was better than that of the MRC technique when the Lc of the MRC technique was 2. The performance of the applied system was lower than that of the MRC technique, then the Lc of the MRC technique was 3. However, as the fading index was lowered, which means the telecommunication environment deteriorated, the performance of the hybrid SC/MRC-(2/3) diversity technique when Lc of MRC technique was 3, was almost the same as that of the MRC technique. The hybrid SC/MRC-(2/3) diversity technique shows a similar performance to that of the MRC technique, when the Lc of the MRC technique was 4. Therefore, it was confirmed that the MC/DS-CDMA system could reduce complexity and achieve similar performance to that of the MRC by applying the hybrid SC/MRC technique, which utilized the advantages of the SC technique and high performance of the MRC scheme, rather than the MRC diversity technique that requires bit synchronization, frequency of fading, and phase synchronization for every diversity branch.

Method of Quasi-Three Dimensional Stability Analysis of the Root Pile System on Slope Reinforcement (사면보강 뿌리말뚝공법의 준3차원적 안정해석기법)

  • Kim, Hong-Taek;Gang, In-Gyu;Park, Sa-Won
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.101-124
    • /
    • 1997
  • The root pile system is insitu soil reinforcement technique that uses a series of reticulately installed micropiles. In terms of mechanical improvement by means of grouted reinform ming elements, the root pile system is similar to the soil nailing system. The main difference between root piles and soil nailing are due to the fact that the reinforcing bars in root piles are normally grouted under high pressure and that the alignments of the reinforcing members differ. Recently, the root pile system has been broadly used to stabilize slopes and retain excavations. The accurate design of the root pile system is, however, a very difficult tass owing to geometric variety and statical indetermination, and to the difficulty in the soilfiles interaction analysis. As a result, moat of the current design methods have been heavily dependent on the experiences and approximate approach. This paper proposes a quasi-three dimensional method of analysis for the root pile system applied to the stabilization of slopes. The proposed methods of analysis include i) a technique to estimate the change in borehole radium as a function of the grout pressure as well as a function of the time when the grout pressure is applied, ii) a technique to evaluate quasi -three dimensional limit-equilibrium stability for sliding, iii) a technique to predict the stability with respect to plastic deformation of the soil between adjacent root piles, and iv) a quasi -three dimensional finite element technique to compute stresses and dis placements of the root pile structure barred on the generalized plane strain condition and composite unit cell concept talon형 with considerations of the group effect and knot effect. By using the proposed technique to estimate the change in borehole radius as a function of the grout pressure as well as a function of the time, the estimations are made and compar ed with the Kleyner 8l Krizek's experimental test results. Also by using the proposed quasi-three dimensional analytical method, analyses have been performed with the aim of pointing out the effects of various factors on the interaction behaviors of the root pile system.

  • PDF

Assessment of MSS Mechanism for Efficient WPS (효율적인 WPS를 위한 MSS기법의 평가)

  • Yi, Hyoun-Sup;Kim, Jin-Deog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.122-124
    • /
    • 2010
  • WPS(Wifi Positioning System) is a location determination technique that utilizes AP information scattered all over the real world. In general, the finger print technique is used for location calculations in WPS. However the finger print technique is a location determination technique that utilizes average values and has problems in the accuracy of the location determination. It also shows low performance of the system due to arithmetic operations. In this paper, the MSS(Max Signal Strength) method is proposed to resolve the existing problems in the finger print technique. The proposed method can reduce the operation time and improve the accuracy of the system under the same conditions. Test environments of the system is presented and the performance of the system is analyzed to verify the methods.

  • PDF

Experimental Study on the Probability-based Equivalent Linearization of a Friction Damper-Brace System (마찰감쇠기-가새 시스템의 확률분포 기반 등가선형화에 관한 실험적 연구)

  • Kang, Kyung-Soo;Park, Ji-Hun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.394-403
    • /
    • 2006
  • A new equivalent linearization technique is proposed for a friction damper-brace system (FDBS) idealized as a elastoplastic system. The equivalent linearization technique utilizes secant stiffness and dissipated energy defined by the probability distribution of the extremal displacement of the FDBS. In addition, a conversion scheme is proposed so that an equivalent linear system is designed first and converted to the FDBS. For comparative study, an existing model update technique based on system identification is modified in a form appropriate to update single element. For the purpose of verification, shaking table tests of a small scale three-story shear building model, in which a rotational FDBS is installed, are conducted and equivalent linear systems are obtained using the proposed technique and the model update technique. Complex eigenvalue analysis is conducted for those equivalent linear systems, and the natural frequencies and modal damping ratios are compared with those obtained from system identification. Additionally, RMS and peak responses obtained from time history analysis of the equivalent linear systems are compared with measured ones.

Development of Optimal Operation Rule for Multipurpose Reservoirs System (다목적댐의 연계운영을 위한 최적 운영률 개발)

  • Yi, Jae-Eung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.6
    • /
    • pp.487-497
    • /
    • 2004
  • Adding important new projects such as reservoirs which regulate a river discharge to a river system, existing operation methods should be changed considering these conditions. Since an original operation rule used for an existing system has been designed to be compatible to inputs and outputs of the existing system, the operation rule should be changed to consider the new projects. In this study, the technique of constructing new operation rules considering objectives of both old and new projects is suggested when new project is added to the river system. Reservoir operation rule using both stochastic inflow and optimization technique is developed. As a result of applying the technique to Geum river basin, the efficiency of the technique is verified.

Estimation Technique of deicing current for configuration of deicing system in conventional line (기존선 해빙시스템 구성을 위한 해빙전류 예측기법)

  • Jung, Ho-Sung;Kwon, Sam-Young;Park, Young;Ahn, Byeong-Lib;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.288-290
    • /
    • 2005
  • Deicing system operated in high speed line is to melt frost or ice freezed in catenary line when the temperature is lower than 0 in winter. The principle of deicing system is to m디t frost or ice by Joule heat of catenary impedance. The performance of deicing is dependant of deicing current determined by the length of deicing section, deicing impedance and current division ratio of catenary line and messenger line. So, We present technique for estimating deicing current in convention line. Deicing impedance is estimated using Carson - Pollaczek, current division ratio of catenary line and messenger line is estimated using voltage drop, and deicing current is estimated using power system data of operation secion for deicing system in this technique. To verify the validity of technique, we compare the estimated current using technique of this paper with deicng current of high speed line.

  • PDF

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Design of a Novel Multi-Dimensional HCOC Multi-code Spread Spectrum System Using Pre-coding Technique for High Speed Data Transmission of DS-CDMA

  • Kong, Hyung-Yun;Lee, Dong-Un
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • Recently, Mc(Multi-code) modulation/demodulation(modem) technique has been explored for high speed data transmission in wireless environment. The conventional Mc modem generates some side effects such as allocating Walsh codes, which motivates to propose a novel Mc modem method with sub-code. Our proposed system should expanded the size of sub-code to provide high-rate data transmission, which also affect adversely to the performance of the system with high PAPR(Peak to Average Power Ratio). Thus, in this paper, we propose a novel pre-coded Multi-Dimensional HCOC(High Capacity Orthogonal Code) Mc modem technique to reduce the high PAPR, which enables the performance improvement. This proposed system can be easily designed by concatenating HCOC Mc modem with the generic Mc modem. The pre-coding technique that is used in this paper is CAC(Constant Amplitude Coding), that helps the system maintain the constant transmission power and reduce the maximum transmission power.