• Title/Summary/Keyword: System operation line

Search Result 1,503, Processing Time 0.037 seconds

On-Line Fault Diagnosis System using Neural Network (신경망을 이용한 실시간 고장 진단 시스템)

  • 김문성;유승선;소정훈;곽훈성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11C
    • /
    • pp.75-84
    • /
    • 2001
  • In this paper, we propose an on-line FDD(Fault Detection and Diagnosis) system based on the three layer feed-forward neural network which is trained by the back-propagation teaming algorithm. We implement the on-line fault detection and diagnosis system by Visual C++ and Visual Basic. The proposed FDD system is applied to an air handling unit in operation. Experimental results show the high performance of our system in the task of fault detection and diagnosis.

  • PDF

Implementation and Effectiveness of Smart Equipment Engineering System (스마트 설비관리시스템 구축 및 효과분석)

  • Sim, Hyun-Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2017
  • EES System support to maximize equipment efficiency by providing real-time information of main equipment which has a significant effect on product quality and productivity, and to prevent equipment failure by detecting equipment abnormality in advance. Smart Equipment Engineering System(S-EES) integrates the activities performed at equipment that are the core of production activities and manages them by system so as to maximize the efficiency of equipment and raise the quality level of products to one level. In other words, when the product is put into the equipment, the recipe is downloaded through the RMS, the recipe is set to the optimal condition through R2R(process control), and the system detects and controls the abnormality of the equipment during operation through the FDC function in real time it means. In this way, we are working with the suitable recipe that matches the lot of product, detecting the abnormality of the equipment during operation, preventing the product from being defective, and establishing a system to maximize the efficiency through real-time equipment management. In this study, we review the present status and problems of equipment management in actual production lines, collect the requirements of the manufacturing line for the PCB line, design and develop the system, The measurement model was studied.

  • PDF

A Study on Permissible Operation Limit of Distributed Generation System in Distribution System (배전계통에서 분산전원 운전가능 범위에 대한 연구)

  • Jung, Won-Jae;Kim, Tae-Eung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.19-21
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case it is difficult to properly maintain the terminal voltage of low voltage customers by using only LDC(Line Drop Compensator). So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper clarifies the relationship between LDC voltage regulation principle and real, reactive power of DGS, and examines the permissible operation limit of the introduced DGS in distribution system which the voltage is controlled by LDC.

  • PDF

Series Line Compensation through Voltage Source Inverter (전압원 인버터에 의한 선로의 직렬보상)

  • 한병문;한경희;신익상;강중구
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.299-302
    • /
    • 1997
  • This paper describes a dynamic var compensator to compensate the line reactance for power transmission and distribution system. The compensator consists of a voltage source inverter with dc capacitor, coupling transformers, and control circuit. The operation of compensator was verified by computer simulations with EMPT and experimental works with a scaled hardware model. The advantage of the proposed system is rapid and continuous regulation of the reactive power.

  • PDF

A NOVEL MERHOO AND PROCEDURE FOR ON-LINE MEASUREMENT OF FLUID PROPERTIES FOR CONTROL AND OPTIMIZATION

  • Kaya, Azmi;Keyes, Marion-A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.844-847
    • /
    • 1989
  • This work describes an on-line method and procedure for calculating the fluid properties in real time while system is in operation. The method utilizes function blocks of distributed control systems. Thermodynamic relations of fluid from tables along with a fluid property formula are imbedded into the proposed signal processing block. Once the pressure and temperature measurements are entered the system provides other properties.

  • PDF

A Study of the Optimal Condenser Operation in Distribution System (배전선로의 적정 콘덴서 운용 연구)

  • Jeon, Young-Soo;Jang, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1238-1240
    • /
    • 1998
  • For economic operating of distribution system, utility has to minimize the loss in distribution line by controlling reactive power and power factor. This paper presents calculation of reactive power in distribution line, estimation of the condenser capacity according to distance, and computation of optimal location and proper condenser capacity.

  • PDF

A Study on The Power Line Communication Module for a Rainwater Management System (빗물관리 시스템을 위한 전력선 통신 모듈에 관한 연구)

  • Jung, Yong-Chae;Jung, Ho-Seok;Kim, Jeong-Uk
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.500-502
    • /
    • 2007
  • In case Power Line Communication (PLC) method is applied to a rainwater monitoring system, PLC module should be utilized. In this paper, PLC module using ST7538Q is implemented. The design rules of the IC peripheral circuit are explained in detail. The operation of the implemented PLC module is verified through the experimental results.

  • PDF

The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway (교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션)

  • 창상훈;이장무
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF

Study on the Calculation of the Optimal Power Operation Considering Line Contingencies (상정사고를 고려한 전력계통 최적운용에 관한 연구)

  • 박영문;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.241-246
    • /
    • 1984
  • The power system scheduling process is formulated as an optimization problem with linear inequality constraints. AC Loadflow method is used for the problem solution and line losses are considered. The constraints under consiceration are generator power limits, load schedding limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time applications.

  • PDF