• 제목/요약/키워드: System of radiation protection

검색결과 406건 처리시간 0.024초

국내 원자력발전소 방사선작업에 대한 피폭 분석 및 대표 고 피폭 작업 선정 (Exposure Analysis and Selection of Representative High Exposure Tasks for Radiation Work in Domestic Nuclear Power Plants)

  • 이찬양;임영기;김광표
    • 방사선산업학회지
    • /
    • 제18권2호
    • /
    • pp.117-126
    • /
    • 2024
  • This study aims to identify high exposure tasks among the tasks performed in domestic nuclear power plants as a basis for developing training programs to improve the efficiency of workers' work. To this end, we first analyzed the exposure status of radiation work in domestic nuclear power plants. Radiation tasks in nuclear power plants were categorized, collective doses were investigated, and the collective doses were calculated based on the collective doses, and representative high exposure tasks were identified. We found that the collective and individual doses in domestic nuclear power plants are continuously decreasing, but there is an imbalance of exposure among workers. In terms of work classification, nuclear power plants are managed in 236 work codes based on light water reactors and 181 work codes based on heavy water reactors, depending on the work equipment and location. Among the total work codes, 23 codes have an annual average dose exceeding 10 μSv, and based on this, 10 representative high exposure tasks were derived. The representative high exposure tasks were selected as S/G nozzle dam work, S/G debris removal work, nuclear instrumentation system, S/G eddy current detection work, and insulation work. The results of this study are expected to serve as an important basis for reducing the exposure of workers in nuclear power plants and improving work efficiency.

경수로 사용후핵연료 건식 중간저장시설에 대한 예비 방사선 영향 평가 (Preliminary Assessment of Radiation Impact from Dry Storage Facilities for PWR Spent Fuel)

  • 김태만;백창열;차길용;이우교;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제37권4호
    • /
    • pp.197-201
    • /
    • 2012
  • 경수로 사용후핵연료 중간저장시설의 부지면적을 산출하기 위하여 콘크리트 저장시설 개념모델의 연간선량을 계산하였다. 초기농축도 4.5 wt%, 연소도 45,000 MWd/MTU, 냉각기간 10년인 사용후핵연료를 대상으로 ORIGEN-ARP를 사용하여 선원항을 생산하였으며, MCNP 코드를 사용하여 저장시설에 대한 모델링 및 방사선차폐계산을 수행하였다. 연간선량은 저장시설의 용량별로 계산하였으며, 중앙집중식 저장시설의 경우, 반경 700 m 이상에서 10CFR72에서 권고하는 통제구역 경계에서의 연간선량 기준 0.25 mSv를 만족하였다.

방사성 물질 등의 이용 증가에 따른 안전 관리 문제점 고찰 (The Increased Use of Radiation Requires Enhanced Activities Regarding Radiation Safety Control)

  • 이윤종;이진우;정교성
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.103-109
    • /
    • 2015
  • More recently, companies that have obtained permission to use radioactive materials or radiation device and registered radiation workers have increased by 10% and 4% respectively. The increased use of radiation could have an effect on radiation safety control. However, there is not nearly enough manpower and budget compared to the number of workers and facilities. This paper will suggest a counteroffer thought analyzing pending issues. The results of this paper indicate that there are 47 and 31.3 workers per radiation protection officer in educational and research institutes, respectively. There are 20.1 persons per RPO in hospitals, even though there are 2 RPOs appointed. Those with a special license as a radioisotope handler were ruled out as possible managers because medical doctors who have a special license for radioisotope handling normally have no experience with radiation safety. The number of staff members and budget have been insufficient for safety control at most educational and research institutes. It is necessary to build an optimized safety control system for effective Radiation Safety Control. This will reduce the risk factor of safety, and a few RPOs can be supplied for efficiency and convenience.

Risk Assessment from Heterogeneous Energy Deposition in Tissue. The Problem of Effects from Low Doses of Ionizing Radiation

  • Le, Feinendegen;J, Booz
    • 대한핵의학회지
    • /
    • 제26권1호
    • /
    • pp.8-13
    • /
    • 1992
  • Low doses of ionizing radiation from external or internal sources cause heterogeneous distribution of energy deposition events in the exposed biological system. With the cell being the individual element of the tissue system, the fraction of cells hit, the dose received by the hit, and the biological response of the cell to the dose received eventually determine the effect in tissue. The hit cell may experience detriment, such as change in its DNA leading to a malignant transformation, or it may derive benefit in terms of an adaptive response such as a temporary improvement of DNA repair or temporary prevention of effects from intracellular radicals through enhanced radical detoxification. These responses are protective also to toxic substances that are generated during normal metabolism. Within a multicellular system, the probability of detriment must be weighed against the probability of benefit through adaptive responses with protection against various toxic agents including those produced by normal metabolism. Because irradiation can principally induce both, detriment and adaptive responses, one type of affected cells may not be simply summed up at the expense of cells with other types of effects, in assessing risk to tissue. An inventory of various types of effects in the blood forming system of mammals, even with large ranges of uncertainty, uncovers the possibility of benefit to the system from exposure to low doses of low LET radiation. This experimental approach may complement epidemiological data on individuals exposed to low doses of ionizing radiation and may lead to a more rational appraisal of risk.

  • PDF

방사선 에너지 분석을 위한 MCA시스템 제작에 관한 연구 (Construction of Multichannel Analyser with Successive Approximation Type ADC)

  • 육종철;오병훈;김영균
    • Journal of Radiation Protection and Research
    • /
    • 제12권1호
    • /
    • pp.12-25
    • /
    • 1987
  • SA(Successive Approximation)형 ADC(Analog to Digital Converter)를 사용하여 방사선다중채널파고 분석기를 설계 제작하였다. 선형게이트, 윈도우 및 펄스스트레처는 논리 IC와 선형 IC들을 위주로 결합하여 구성하였으며, 분석시간이 $120{\mu}sec$인 ADC 1211(12 bit)을 중심으로 한 ADC 모듈의 메모리로는 S-RAM 6264 (Address 13 bit, Data 8 bit) 2개를 병렬로 연결하여 사용하였다. 마이크로 컴퓨터 (Apple II)가 전체 시스템을 제어하고 또 계측된 결과의 데이타를 분석할 수 있도록 인터페이스와 소프트 웨어도 만들었다. 제작된 시스템의 동작시험은 표준펄스 발생기로 $0{\sim}10V$ 사이의 일정한 펄스를 만들어 시스템에 입력시켜 그 펄스들을 계측하게 하고, 계측이 끝난 후 컴퓨터가 그 결과를 받아들여 분석하게 함으로써 이루어졌다.

  • PDF

차폐천이 물리치료실 환경내 전자기장 감소에 미치는 효과 (The Effect of Electromagnetic Fields Shielding on Electromagnetic Fields Decrease in P. T Room)

  • 임창훈;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.69-82
    • /
    • 2000
  • Physical therapists are exposured to radio-and microwave-frequency electromagnetic radiation by operating electrotherapy units. So there is few protection system in physical therapy room. Clinical pathology room and so on where various kins of electromagnetic instruments is used in hospital while protection failities like protection wall or protection glass is being used only in radiological room to reduce the damage of radiation. Acoording to Larsen's survey on female physical therapist in denmark. it was said that the percentage of congenital malfornation was $3.6\%$ and cadiac malformation made up $0.7\%$. It is likely that effect of electromagnetic fields on the result cannot be ruled out. Rita ouellet-Hellstron and Walter F. Steward insisted that the danger of abortion increase in the case of pregnant femeal physical therapist exposured to microwave diathermy. The intention of our study is arousing the necessity of microwave protection in P.T room and finding the proper method for physical therapist safe. The results of this study were as follows: 1. Each electrotherapy units are occurrenced the electromagnetic fields, and specially amply occurrenced in H.P,I.C.T 2 unit operating, M.W.D unit head on parallel, S.W.D unit head on parallel. all electrotherapy units are operating. 2. There were electric fields mount are consideration to species of electrotherapy units(p<.05). 3. There were magnetic fields mount are consideration to species of electrotherapy units(p<.05). 4. There were electric fields mount are consideration to distance of electrotherapy units(p<.05). 7. There were magnetic fields mount are consideration nut to distance of electrotherapy units(p>.05). 8. Before and after protection on magnetic fields mount are consideration to all distance(0m, 0.3m, 1m, 3m, 5m)(p<.05) 9. Before and after protection on electric fields mount are consideration to 0m, 1m, 3m distance(p<.05), and consideration not to 0.3m, 5m distance(p>.05) 10. After protection fellow the each electrotherapy units. distance, intencity to electromagnetic fields are reduced(p<.05).

  • PDF

Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities

  • Choi, Sang Hyoun;Shin, Dong Oh;Shin, Jae-ik;Kwon, Na Hye;Ahn, So Hyun;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.83-91
    • /
    • 2021
  • Various types of high-precision radiotherapy, such as intensity-modulated radiation therapy (IMRT), tomotherapy (Tomo), and stereotactic body radiation therapy have been available since 1997. After being covered by insurance in 2015, the number of IMRT cases rapidly increased 18-fold from 2011 to 2018 in Korea. IMRT, which uses a high-beam irradiation monitor unit, requires higher shielding conditions than conventional radiation treatments. However, to date, research on the shielding of facilities using IMRT and the current understanding of its status are insufficient, and detailed safety regulation procedures have not been established. This study investigated the recommended criteria for the shielding evaluation of facilities using medical linear accelerators (LINACs), including 1) the current status of safety management regulations and systems in domestic and international facilities using medical LINACs and 2) the current status of the recommended standards for safety management in domestic and international facilities using medical LINACs. It is necessary to develop and introduce a safety management system for facilities using LINACs for clinical applications that is suitable for the domestic medical environment and corresponds to the safety management systems for LINACs used overseas.

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

  • Ostheimer, Christian;Hubsch, Patrick;Janich, Martin;Gerlach, Reinhard;Vordermark, Dirk
    • Radiation Oncology Journal
    • /
    • 제34권4호
    • /
    • pp.313-321
    • /
    • 2016
  • Purpose: Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). Materials and Methods: A retrospective treatment plan databank search was performed and 5 patient cases were randomly selected. Cranial imaging was restored from the initial planning computed tomography (CT) and target volumes and OAR were redelineated. For each patients, three treatment plans were calculated (coplanar/non-coplanar IMRT, VMAT; prescribed dose 50 Gy, single dose 2 Gy). Conformity, homogeneity and dose volume histograms were used for plan. Results: VMAT featured the lowest monitor units and the sharpest dose gradient (1.6 Gy/mm). Planning target volume (PTV) coverage and homogeneity was better in VMAT (coverage, 0.95; homogeneity index [HI], 0.118) compared to IMRT (coverage, 0.94; HI, 0.119) but coplanar IMRT produced the most conformal plans (conformity index [CI], 0.43). Minimum PTV dose range was 66.8%-88.4% in coplanar, 77.5%-88.2% in non-coplanar IMRT and 82.8%-90.3% in VMAT. Mean dose to the brain, brain stem, optic system (maximum dose) and lenses were 18.6, 13.2, 9.1, and 5.2 Gy for VMAT, 21.9, 13.4, 14.5, and 6.3 Gy for non-coplanar and 22.8, 16.5, 11.5, and 5.9 Gy for coplanar IMRT. Maximum optic chiasm dose was 7.7, 8.4, and 11.1 Gy (non-coplanar IMRT, VMAT, and coplanar IMRT). Conclusion: Target coverage, homogeneity and OAR protection, was slightly superior in VMAT plans which also produced the sharpest dose gradient towards healthy tissue.

월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가 (Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants)

  • 진영권;김용일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.53-64
    • /
    • 1995
  • 월성 원자력발전소 2,3,4 호기의 보조건물 주요 지역에서 냉각재 다량상h7사고 (large LOCA) 후의 방사선장을 평가하였다. 핵분열 생성물의 총량은 ORIGEN2 코드를 사용하여 계산하였고 선원항은 2중고장 시나리오, 즉 LOCA 사고후 비상노심냉각 (ECC) 계통의 고장이 결부된 사고시의 방사능 방출에 근거하였다. 원자로건물, 보조건물 및 ECC 계통의 구조모형을 QAD-CG 모델에 포함하여 계산하였다. 사고시점부터 90일 경과시까지 시간대 별로 선량율과 누적선량을 계산하였다. 결과적으로, 연속출입이 요구되는 중요지역에서의 방사선장은 충분히 낮은 것으로 평가되었다. 그러나, 일부구역에서는 제한적인 출입을 허용할 정도로 상대적으로 높은 방사선장을 나타내었다.

  • PDF

국내 복수호기 원전 운영을 고려한 일반인 선량제약치 설정에 대한 고찰 (A Preliminary Establishment of Dose Constraints for the Member of Public Taking into Account Multi-unit Nuclear Power Plants in Korea)

  • 공태영;최종락;손중권;김희근
    • Journal of Radiation Protection and Research
    • /
    • 제37권3호
    • /
    • pp.129-137
    • /
    • 2012
  • 국제방사선방호위원회(ICRP)는 2007년 발행된 ICRP 103 권고를 통해, 행위와 개입으로 대변되는 방사선방호 지침을 각 피폭상황 별로 적용하도록 변경하여 권고하였다. 이 지침에는 계획피폭상황에서 방사선방호 최적화의 수단으로 방사선작업종사자와 일반인에 대해 선원중심의 선량제약치(dose constraint)를 설정하여 운영하도록 권고하고 있다. 이 논문에서는 계획피폭상황에서 일반인 선량제약치를 설정하는데 필요한 국내 원전의 방사성물질의 배출량과 이에 따른 주변주민의 피폭방사선량 평가 결과를 분석하였다. 이를 바탕으로 국내 원전의 동일부지 내 복수호기 원전의 운영을 고려한 선량제약치 설정 방안을 제시하였다.