• Title/Summary/Keyword: System Calibration

Search Result 2,072, Processing Time 0.035 seconds

Infrared LED Tracking and Aim Position Calibration for an Arcade Gun (아케이드 건(Gun)을 위한 적외선 LED 추적과 조준 위치 보정)

  • Baek, Seong-Ho;Kim, Jong-Soo;Kim, Tae-Yong
    • Journal of Korea Game Society
    • /
    • v.5 no.1
    • /
    • pp.3-10
    • /
    • 2005
  • In this paper, we propose an infrared LED tacking system called IRED Gun, which is designed for the game gun interface. The conventional systems are practically restricted by physical environment and are not robust to the measurement variations. We suggest the IRED Gun system to solve theses problems. Unlike conventional systems, our tracking system uses three infrared LED lights attached on monitor. Since the coordinate calibration is designed to regulate the detected target coordinates, more accurate aim position is calculated, which enables a game player to interact with a game more reliably. The experimental results verify the feasibility and validity of the calibration method and the infrared LED tacking system.

  • PDF

Calibration of the depth measurement system with a laser pointer, a camera and a plain mirror

  • Kim, Hyong-Suk;Lin, Chun-Shin;Gim, Seong-Chan;Chae, Hee-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1994-1998
    • /
    • 2005
  • Characteristic analysis of the depth measurement system with a laser, a camera and a rotating mirror has been done and the parameter calibration technique for it has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. The calibration techniques to minimize the effect of such major parameters are proposed.

  • PDF

Airspeed Calibration of a Light Airplane via Flight Test (비행시험을 통한 경비행기의 속도계 보정)

  • Lee, Jung-Hoon;Yoo, Si-Yoong;Lee, Jang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.629-634
    • /
    • 2008
  • This paper presents the flight test procedure and the results for the airspeed indicator calibration of a light airplane the name of ChangGong-91, which is the first type certified aircraft from Korean Ministry of Construction and Transportation, as a part of the flight test validation to get the certification. The flight tests for airspeed position error calibrations are conducted using tower fly by method in order to calibrate swivel head testboom which is attached to the right wing tip of the airplane. Also system to system method is applied in order to calibrate the airspeed indicator of the cockpit. The flight test is conducted at the basis of the 'Korean Airworthiness Standard' which is the regulation of Korean Ministry of Construction and Transportation. The airspeed error range for the testboom and the airspeed indicator are determined to $-0.75{\sim}+0.75$ knot and to $-4.0{\sim}+2.0$ knots, respectively. The calibration results are applied to ChangGong-91 Flight Operation Manual.

A Study on improving the Reliability of Thrust Measurement System (추력측정장치의 신뢰도 향상 방안에 관한 연구)

  • Kang, Donghyuk;Joo, Seongmin;Kim, Jong-gyu;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1188-1191
    • /
    • 2017
  • Thrust is one of the crucial performance parameter of a combustion chamber in the combustion chamber development test. So it is very important to measure an accurate thrust. Thrust calibration test was performed to identify the system characteristics, resistance and linearity of a vertical thrust measurement system(TMS) for accurate thrust measurement. It has been found 6.9% ~ 8.6% errors between the measured thrust by TMS calibration equations and theoretical thrust. It has been confirmed that the TMS calibration is necessary to be performed with the propellant lines connected to the combustion chamber for accurate thrust measurement.

  • PDF

Geometric error assessment system for linear guideway using laser-photodiodes (레이저-수광소자를 이용한 선형 이송측의 기하학적 오차측정 시스템)

  • Pahk, H.J.;Chu, C.N.;Hwang, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.180-188
    • /
    • 1994
  • Error assessment and evaluation for machine for machine tool slides have been considered as essential tools for improving accuracy. In this paper, a computer aided measurement technique is proposed using photo pin diodes of quadrant type and laser source. In thedeveloped system, three photo diodes are mounted on a sensor mounting table, and the sensored signal is processed by specially designed signal conditioner to give fine resolution with minimum noise. A micro computer inputs the processed signal, and the geometric errors of five degree of freedoms are successfully evaluated. Pitch, roll, yaw, vertical and horizontal straightness errors are thus assessed simultaneously for a machine tool slide. Calibration techniques such as optics calibration, photo diode calibration are proposed and implemented, giving precise calibration for the measurement system. The developed system has been applied to a practical machine tool slide, and has been found as one of efficient and precise technique for machine tool slide.

  • PDF

3-D measuring system for large structures

  • Yamamoto, Masayuki;Matsumoto-Moriyama, Masao;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.60-63
    • /
    • 1993
  • A system to measure 3-dimensional coordinates of large structures is presented in this paper. In order to enable accurate measurements calibration of the measuring system is important. Feature of our system are that by introducting one simplified calibration procedures setting of the measuring system is simplified and also that tracking performance is increased. An experimental result reveals the applicability of our systems.

  • PDF

Pipe Flange Measurement System Using Draw-Wire Sensor (Draw-Wire센서를 이용한 파이프 플랜지 계측시스템)

  • 윤재웅;윤강섭;이수철
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.62-69
    • /
    • 2003
  • In most shipyards, the measurement of 3-dimensional relative position of pipes should be connected in the block depends on the manual operation. It results a very tedious and inefficient procedure, thus the proper measurement system is needed to improve productivity and accuracy. This paper describes the development of pipe measurement system including system concepts, measuring procedures, system calibration, and its accuracy and productivity. And also, the possibility and things to be improved for application in shipyard are discussed in this paper.