• 제목/요약/키워드: Synchronous circuit

검색결과 369건 처리시간 0.024초

동기정류기 강제구동 방식을 이용한 TTFC의 효율 향상에 관한 연구 (A Study on the Efficiency Improvement of TTFC(Two Transistor Forward Converter) using Synchronous Rectifier of Compulsory Control-driver)

  • 배진용;김용;이은영;권순도;한경태;한대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.166-170
    • /
    • 2003
  • This paper presents the TTFC(Two Transistor Forward Converter) using Synchronous Rectifier of Compulsory Control-driver. The two transistor forward circuit is used to decrease voltage stress of primary side and the synchronous rectifier is used to reduce current stress of secondary side. Previous synchronous rectifier's MOSFET of TTFC have long dead time This paper presents synchronous rectifier of compulsory control-driver for minimized dead time. This paper compared with diode rectifier, self-driven synchronous rectifier and compulsory control-driver synchronous rectifier of TTFC. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 200W 100kHz MOSFET based experimental circuit.

  • PDF

단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석 (Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters)

  • 강규홍;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토 (Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network)

  • 최순호;이성두;김찬기
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

컴퓨터를 이용한 순차 논리 회로의 설계 (동기식 순차 논리 회로의 경우) (Computer Aided Design of Sequential Logic Circuits (Case of Synchronous Sequential Logic Circuits))

  • 김경식;조동섭;황희영
    • 대한전기학회논문지
    • /
    • 제33권4호
    • /
    • pp.134-139
    • /
    • 1984
  • This paper presents the computer program to design the synchronous sequential logic circuit. The computer program uses the MASK method to get the circuit of optimal cost. The computer program takes as an input, the minimal reduced state transition table where each state has its internal code. As an output,the optimal design of synchronous sequential logic circuit is generated for each flipflop type of JK,T,D, and RS respectively. And these circuits for 4 flipflop types are evaluated and sorted in ascending order of their costs, so that the user can select the proper flipflop type and its circuit. Furthermore,the proposed computer program may be applied to state assignment with its facility of cost evaluation.

  • PDF

직렬-병렬 공진 무선전력전송 시스템의 동기 좌표계 모델 (DQ Synchronous Reference Frame Model of a Series-Parallel Tuned Inductive Power Transfer System)

  • 노은총;이상민;이승환
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.477-483
    • /
    • 2020
  • This study proposes a DQ synchronous reference frame model of a series-parallel tuned inductive power transfer (SP-IPT) system. The wireless power transmission system experiences control difficulty because the transmitter-side controller cannot directly measure the receiver-side load voltages and currents. Therefore, a control-oriented circuit model that shows the dynamics of the IPT system is required to achieve a well-behaved controller. In this study, an equivalent circuit model of the SP-IPT system in a synchronously rotating reference frame is proposed using the single-phase DQ transformation technique. The proposed circuit model is helpful in modeling the dynamics of the voltages and currents of the transmitter- and receiver-side resonant tanks and loads. The proposed circuit model is evaluated using frequency- and time-domain simulation results.

고전압 비교기를 적용한 스마트 센서용 SECE 에너지 하베스트 인터페이스 회로 설계 (Design of SECE Energy Harvest Interface Circuit with High Voltage Comparator for Smart Sensor)

  • 석인철;이경호;한석붕
    • 한국전자통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.529-536
    • /
    • 2019
  • 스마트 센서 시스템에 압전 에너지 하베스터를 적용하기 위해서는 AC-DC 정류기를 비롯한 에너지 하베스트 인터페이스 회로가 필수적이다. 본 논문에서는 기본적인 회로인 Full Bridge Rectifier(: FBR) 회로와 동기식 압전 에너지 하베스트 인터페이스 회로의 성능을 보드레벨 시뮬레이션으로 비교하였다. 그 결과, 동기식 압전 에너지 하베스트 인터페이스 회로 중 하나인 Synchronous Electric Charge Extraction(: SECE) 회로가 FBR에 비해 출력 전력이 약 4 배 이상 더 컸고, 부하 변동에도 변화가 거의 없었다. 그리고, 출력 전압이 40V 이상인 압전 에너지 하베스터용 SECE 회로에 필수적인 고전압 비교기를 0.35 um BCD 공정으로 설계하였다. 설계한 고전압 비교기를 적용한 SECE 회로는 출력 전력이 FBR 회로 보다 427 % 향상됨을 검증하였다.

다출력 플라이백 컨버터를 위한 자동 동기 스위치 포스트 레귤레이터 (An Automatic Synchronous Switch Post Regulator for Multi-Output Flyback Converter)

  • 김호진;이해교;양승욱;목형수;최규하;이성주
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.321-327
    • /
    • 2006
  • 본 논문은 다출력 전원장치에 적용되는 플라이백 컨버터를 위한 자동 동기 스위치 포스트 레굴레이터를 제안한다. 제안된 회로는 기존의 스위치 포스트 레굴레이터의 단점인 구동회로 구현 및 주 출력과 보조 출력의 동기의 어려움으로 인한 복잡한 회로구성이 새로운 자동동기 스위치로 간단하게 구성된다. 제안된 회로를 적용함으로서 각 출력의 전압가변과 정밀한 레굴레이션이 요구되는 다중출력 전원장치를 간단한 구성과 저렴한 가격으로 제작할 수 있으며, 이론적 해석 및 시뮬레이션 그리고 실험을 통하여 제안 회로의 타당성을 입증하였다.

여자시스템과 동기발전기의 회전자 권선에 발생되는 과전압에 대한 보호회로 연구 (The study of the protection circuit about overvoltage between excitation system and synchronous machines)

  • 류호선;임익헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.188-192
    • /
    • 1997
  • In the case of synchronous machines, certain power system disturbances cause the induced rotor current to assume negative values when no static converter is present. A converter, however, prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. This newly proposed crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly and verified through experiment

  • PDF

PMG Type 디지털 AVR을 이용한 선박용 동기발전기 출력전압제어 (Voltage Control of Synchronous Generator for Ships using a PMG Type Digital Automatic Voltage Regulator)

  • 유동환;박상훈;원충연;유재성;이상석;안성준
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2009
  • 일정 출력을 얻기 위해 동기발전기 계자 여자는 AVR에 의해 제어된다. 대부분의 선박용 동기발전기 AVR은 사이리스터 위상제어 방식을 사용한다. 하지만 이 방식은 제어 주기가 MOSFET이나 IGBT로 구성된 컨버터에 비해 느리므로 속응 제어를 구현하는데 어려움이 있다. 따라서 본 논문에서는 선박용 동기발전기에 MOSFET을 사용한 PMG형 디지털 AVR을 구현하였다. PMG형 디지털 AVR 회로 구성은 간단하고 단락 시 발전기 출력전압이 영으로 되어 AVR이 동작하지 못하므로 출력전류를 여자회로로 흐르도록 하는 CBC가 요구된다. 본 논문에서 연구된 여자 시스템은 실제 선박용 발전기를 대신하여 10[kVA]급 프로토타입의 실험을 통하여 시스템의 타당성을 검증하였다.

A Coupled Circuit and Field Analysis of a Stand-Alone Permanent-Magnet Synchronous Generator with Inset Rotor

  • Chan T. F.;Yan Lie-Tong;Lai L. L.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.253-257
    • /
    • 2005
  • By using a coupled circuit, time-stepping, two-dimensional finite element method (2-D FEM), the performance of a stand-alone permanent-magnet synchronous generator (PMSG) with inset rotor can be computed without involving the classical two-axis model. The effects of interpolar air gap length and armature resistance on the load characteristics are investigated. It is shown that the interpolar flux density, and hence the amount of voltage compensation, is affected by magnetic saturation. Validity of the coupled circuit and field analysis is confirmed by experiments on a prototype generator. The machine exhibits an approximately level load characteristic when it is supplying an isolated unity-power-factor load.