• Title/Summary/Keyword: Synchronous Control

Search Result 1,730, Processing Time 0.036 seconds

Robust Speed Control of a Permanent Magnet Synchronous Motor using a Fuzzy Logic Controller (퍼지제어기를 이용한 영구자석 동기전동기의 강인한 속도제어)

  • Choi, Young-Sik;Yu, Dong-Young;Jung, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.343-351
    • /
    • 2010
  • This paper proposes a new fuzzy speed controller based on the Takagi-Sugeno fuzzy method to achieve a robust speed control of a permanent magnet synchronous motor (PMSM). The proposed controller requires the information of the load torque, so the second-order load torque observer is used to estimate it. The LMI condition is derived for the existence of the proposed fuzzy speed controller, and the gains of the controller are provided. It is proven that the augmented control system including the fuzzy speed controller and the load torque observer is exponentially stable. To evaluate the performance of the proposed fuzzy speed controller, the simulation and experimental results are presented under motor parameter variations. Finally, it is clearly verified that the proposed control method can accurately control the speed of a permanent magnet synchronous motor.

A study on the Scheme of Extending Break Power Controller for Permanent Magnet Synchronous Motor(PMSM) using a Microprocessorr (마이크로프로세서를 이용한 영구자석형 동기전동기(PMSM) 제동력 확보 제어기 설계에 관한 연구)

  • Na, Seung-Kwon;Kim, Yeong-Wook;Choi, Gi-Ho;Hwang, Lark-Hoon
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.5
    • /
    • pp.524-544
    • /
    • 2013
  • In this paper, A tow system of miniature establishes each motor to individual 1C1M methods to control for a permanent magnet synchronous motors (PMSM) is constructed. You assume that is wiring having had the ability that can all absorb regenerative power which occurred when permanent magnet synchronous motors(PMSM) brake is all used to it, and to occur about agreement use scope expansion my electricity. To regenerative braking power securities of a PMSM and to stop of the bronzes my a control security, and that the electricity as you apply to vector control method and an speed sensor of controller to microprocessor, And you studied to speed, motor electricity energy control method to the algorithm and you brake a revival by regenerative braking power securities of a permanent magnet synchronous motors. It is proposed that motor control method to the algorithm you brake a revival by electricity braking power securities, you do to simulations regarding a momentum load and experiment.

Design and Implementation of Channel Allocation Module of Synchronous Area in MOST Network (MOST 네트워크의 동기영역 채널 할당 모듈 설계 및 구현)

  • Jang, Si-Woong;Kwak, Gil-Bong;Yu, Yoon-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1397-1402
    • /
    • 2010
  • While MOST is an in-vehicle network which transfers concurrently synchronous data, asynchronous data and control data, it provides high bandwidth synchronous section which can transfer video and audio without buffering. To transfer real time data using synchronous section, connections between source node and sink node, and channel allocation for connections are required. In this paper, we proposed synchronous data transfer method and channel allocation method by constructing MOST network after designing and implementing channel allocation module for using synchronous data section.

A Study on the Improvement of Active Noise Control using Synchronous Sampling Method (Synchronous sampling method를 이용한 능동소음제어 성능 향상에 관한 연구)

  • Oh, Jae-Eung;Jo, Sung-O;Kim, Heung-Seob;Shin, Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.125-130
    • /
    • 1993
  • 본 연구에서는 소음의 주기성분에 해당하는 전기적 참조신호인 주기적 펄스 신호(pulse train)를 사용하는 실시간 제어용 어셈블리 프로그램을 작성하고, Synchronous Sampling Method를 사용하여 능동소음제어를 실시, 이것에 대 한 장단점 및 한계를 고찰하는데 있다.

  • PDF

Internet Web-Based Remote Control System for Permanent Magnet Synchronous Motor Drives (인터넷 웹 기반의 PMSM 원격 제어시스템)

  • Kim, Dai-Hyun;Choi, Yang-Kwang;Kim, Young-Seok;Lee, Eul-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.42-44
    • /
    • 2003
  • As the industry is developed, uses of various electric motor are increasing from general home to various fields of industry, and the kind becomes various daily. For these reasons, it is required to study the remote control and a package management about change of a speed drive system, the supervision of administration appliance by real time, and the collection and process data together using internet prevailed on industry whole. This paper deals with the development of a Web-Based remote control system for permanent magnet synchronous motor drives. The client/server system using TCP/IP protocols and DSP controller for remote control through internet and the Web interface that users can confirm data and state of PMSM(Permanent Magnet Synchronous Motor) is developed. This system is available for driving, braking, variable speed control and monitoring for PMSM in real time through administration program of Web-Based.

  • PDF

Parallel Sensorless Speed Control using Power Angle for Dual SPMSMs Fed by a Single Inverter (단일 인버터 기반 두 대의 영구자석 동기전동기 병렬운전에서 전력각을 이용한 속도제어기법)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.10
    • /
    • pp.1481-1487
    • /
    • 2017
  • This paper proposes a sensorless speed control algorithm for parallel-connected dual Surface-mounted Permanent Magnet Synchronous Motors fed by a single inverter. For stable parallel operation of synchronous motors with a single inverter, each motor has to be constantly kept in the synchronization state regardless of load torque. If the master motor with the larger load is controlled, the synchronous state will be maintained. Therefore, detection of the master motor is essential. Conventionally, the master motor is determined by comparing the rotor position error from the relation between the back-EMF for torque angle and the flux position. consequently, the position sensor is deemed essential for finding the rotor position. In this paper, we proposed a method that decides the magnitude of the load from the power angle of two motors due to the load variation and selects the motor to control through the sign function for the sensorless speed control without the position sensor. The results of simulation and experiment conducted verify the efficacy of the proposed method.

Mathematical Analysis and Simulation Based Survey on Initial Pole Position Estimation of Surface Permanent Magnet Synchronous Motor

  • Kim, Tae-Woong;Wheeler, Patrick;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.499-506
    • /
    • 2009
  • In this paper, the initial pole-position estimation of a surface (non-salient) permanent magnet synchronous motor is mathematically analyzed and surveyed on the basis of simulation analysis, and developed for accurate servo motor drive. This algorithm is well carried out under the full closed-loop position control without any pole sensors and is completely insensitive to any motor parameters. This estimation is based on the principle that the initial pole-position is simply calculated by the reverse trigonometric function using the two feedback currents in the full closed-loop position control. The proposed algorithm consists of the predefined reference position profile, the information of feedback currents, speed, and relative position, and the reverse trigonometric function for the initial-pole position estimation. Comparing with the existing researches, the mathematical analysis is introduced to get a more accurate initial pole-position of the surface permanent magnet motor under the closed-loop position control. It is found that the proposed algorithm can be easily applied in servo drive applications because it satisfies the following user's specifications; accuracy and moving distance.

Torque Ripple Reduction of an Interior PM Synchronous Motor by Compensating Harmonic Currents Based on Flux Linkage Harmonics

  • Nam, Myung Joon;Kim, Jong Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone;Cho, Younghoon
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1223-1230
    • /
    • 2017
  • The back emf harmonics of a permanent magnet (PM) synchronous motor is a major source of torque ripple. For torque control applications including column fitted MDPS (motor driven power steering) systems, it is essential to reduce the mechanical vibrations due to torque ripples at low speeds. In this paper, a torque ripple reduction algorithm for interior PM synchronous motors is proposed. The harmonic currents that cancel the $6^{th}$ order torque harmonic are added to the nominal dq currents for MTPA (maximum torque per ampere) operation. The compensated harmonic currents are derived from flux linkage harmonics based on a FFT analysis of the back emf harmonics. Simulation and experimental results verify that the $6^{th}$ order torque harmonic and THD of the torque ripple are reduced by compensating the dq harmonic currents.

An Improved Flux Estimator for Gap Flux Orientation Control of DC-Excited Synchronous Machines

  • Xu, Yajun;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.419-430
    • /
    • 2015
  • Flux estimation is a significant foundation of high-performance control for DC-excited synchronous motor. For almost all flux estimators, such as the flux estimator based on phase locked loop (PLL), DC drift causes fluctuations in flux magnitude. Furthermore, significant dynamic error may be introduced at transient conditions. To overcome these problems, this paper proposes an improved flux estimator for the PLL-based algorithm. Filters based on the generalized integrator are used to avoid flux fluctuation problems caused by the DC drift at the back electromotive force. Programmable low-pass filters are employed to improve the dynamic performance of the flux estimator, and the cutoff frequency of the filter is determined by the dynamic factor. The algorithm is verified by a 960V/1.6MW industrial prototype. Simulation and experimental results show that the proposed estimator can estimate the flux more accurately than the PLL-based algorithm in a cycloconverter-fed DC-excited synchronous machine vector control system.

Robust Digital Speed Control Scheme of Permanent Magnet Synchronous Motor (영구자석 동기전동기의 강인한 디지털 속도 제어기법)

  • Jung, Jin-Woo;Choi, Young-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2011
  • This paper proposes a robust digital speed regulator for a surface-mounted permanent magnet synchronous motor(SPMSM). The proposed speed controller uses a simple digital load disturbance resistance scheme which does not require a load torque observer, so it can be easily and simply implemented without degrading the control performance. To validate the effectiveness of the proposed control algorithm, experimental results as well as simulation results are shown under motor parameter variations using a prototype SPMSM driving system. Finally, it was confirmed that the proposed method can precisely regulate the speed of the SPMSM.