• 제목/요약/키워드: Synchronous Control

검색결과 1,730건 처리시간 0.026초

A New Unity Power Factor Rectifier System using an Active Waveshaping Technique

  • Choi, Se-Wan;Bae, Young-Sang
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.173-179
    • /
    • 2009
  • This paper proposes a new three-phase diode rectifier system with a sinusoidal input current at unity power factor and a regulated and isolated output voltage at low level. The inherent natural wave-shaping capability of the reduced kVA polyphase transformer together with an active current wave-shaping technique results in a significant reduction of input and output filter requirements associated with switching ripple and EMI. The operation principles are described along with a design example and a comparative evaluation. Experimental results on a 1.5kW prototype are provided to validate the proposed concept.

슬라이딩 모드 관측기를 이용한 고속 영역에서의 PMSM 센서리스 제어에 관한 연구 (A Study on Sensorless Control of a PMSM using Sliding Mode Observer in High Speed Range)

  • 강계룡;김장목;이상혁;황근배;김경훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.30-36
    • /
    • 2004
  • An iterative sliding mode observer is proposed to sensorless control of a PMSM(Permanent Magnet Synchronous Motor). The proposed sliding mode observer has the character which is robust to the disturbance and parameters variation. A low pass filter with the variable cut-off frequency is also proposed to compensate the delay of the rotor angle according to the rotor speed, it is led to save memory and minimize operation time. Experimental results show that the proposed sliding mode observer leads to the proper performance.

NAVER : PC 클러스터 기반의 분산가상환경 커널 설계 및 구현 (NAVER : Design and Implementation of Networked Virtual Environments Based on PC Cluster)

  • Park, Chang-Hoon;Ko, Hee-Dong;Changseok Cho;Ahn, Hee-Kap;Han, Yo-Sub;Kim, Tai-Yun
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 춘계학술대회 논문집
    • /
    • pp.221-228
    • /
    • 2002
  • The NAVER is based on a cluster of low-cost personal computers. The goal of NAVER is to provide flexible, extensible, scalable and re-configurable framework for the diverse virtual environments especially for Gamsung research experiments. Personal computers are divided into three servers are according to their specific functions: Render Server, Device Server and Control Server. While Device Server contains external modules requiring event-based communication for the integration, Control Server contains external modules requiring synchronous communication every frame. And, the Render Server consists of 5 managers: Scenario Manager, Event Manger, Command Manager, Interaction Manager and Sync Manager. In this paper, we discuss NAVER as effective distributed system and its application to Gamsung experiment.

  • PDF

강인한 적응 제어기를 이용한 영구자석 동기 전동기의 속도 제어 (Speed Control of PMSM Using a Robust Adaptive Controller)

  • 권정진;한우용;이창구;김성중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.271-273
    • /
    • 2001
  • This paper presents a adaptive speed controller for field oriented controlled (FOC) permanent magnet synchronous motor (PMSM) drives. However, achieving FOC requires machine specific knowledge, and tracking of drifting motor parameters in order to maintain control. The proposed controller based on Minimum Controller Syntheses (MCS) algorithm does not require exact knowledge of motor parameters. This controller structure simplifies the design and implementation of the adaptive controller requiring less effort to synthesis than a standard MRAC system. Simulation results using Matlab/Simulink show that the proposed controller has good dynamic performances and it is insensitive to parameter variations.

  • PDF

Halbach 배열을 갖는 공심형 PMLSM의 동특성 해석 (Dynamic Analysis and Control Simulation of the Air-Core PMLSM with Halbach Arrays)

  • 장석명;장건우;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.72-74
    • /
    • 2001
  • This paper deals with a dynamic analysis and a position control for air-core type linear synchronous motor with Halbach array (HA) permanent magnet mover. The primary coils are designed to be air-cored, so the HA-PMLSM don't exist the detent force. The secondary HA array of PMs does not require any ferro-magnetic yoke and excites stronger magnetic flux density and closer to the sinusoids than a conventional PM array.

  • PDF

상태관측기를 이용한 IPMSM의 센서리스 제어 (Sensorless Control of IPMSM using State Observer)

  • 송재주;이정철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.71-74
    • /
    • 2003
  • The paper is proposed to position and speed control of interior permanent magnet synchronous motor(IPMSM) drive without mechanical sensor. A minimum order state observer is used for the mechanical state estimation of the motor. The observer was developed based on nonlinear model of IPMSM, that employs a d-q rotating reference frame attached to the rotor. A minimum order state observer is implemented to compute the speed and position feedback signal. The validity of the proposed sensorless scheme is confirmed by various response characteristics.

  • PDF

제어 변수 도출에 의한 직선형 동기 전동기의 최적 설계 (Optimal design of PMLSM with moving coil mover through control parameter estimation)

  • 장석명;유대준;조한욱;고경진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.893-894
    • /
    • 2006
  • This paper presents a design and analysis solutions for the general class and control parameter estimation of slotted iron-cored Permanent Magnet Linear Synchronous Motor with Halbach magnetization stator and 3-phase winding mover. In our design and analysis, stator consisting of permanent magnets and slotted iron-cored coil mover are treated in a uniform way via magnetic vector potential. For one such motor structure, we give analytical formulas for its magnetic field, back electromotive force and trust force. Moreover, the detent force are calculated by the relative permeance function. In good agreement with the estimated values from the analyses, the experimental results and Finite Element Method (FEM) confirm the validity of the design and analysis framework.

  • PDF

상태 궤환 전류 제어기의 이득 분석 및 설계 (Analysis and Design of the State Feedback Current Controller's Gain)

  • 이진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.982-983
    • /
    • 2006
  • This paper deals with an analysis and design of the state feedback current controller's gain in the three-phase current control systems. First, this paper derives the transfer function of the closed loop current control system and also compares the state feedback current controller with the conventional proportional integral controller. A new pole placement method by using the pole/zero cancellation method is proposed to give a simple and concrete concept with respect to the pole selection. Experimental results on the permanent magnet synchronous motor show that the proposed method is very useful to design the gain of the state feedback current controller.

  • PDF

고속 전철 견인용 영구자석 전동기의 고조파 철손해석 (Harmonic Iron Loss Analysis of Permanent Magnet Motor for High-Speed Train)

  • 서장호;정태경;정상용;이철균;정현교
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.335-341
    • /
    • 2009
  • 차세대 고속 전철용 매입형 영구자석 전동기의 효율 및 매입된 자석의 감자를 방지하기 위해서 정확한 철손해석과 철손특성을 이해하는 것은 전동기 설계단계에서 매우 중요하다. 본 논문에서는 견인전동기의 약계자 제어 및 최대토크 제어와 같은 구동상황을 고려하여 운전영역별 철손해석을 수행하고 특성을 분석하고자 한다.

PMSM의 자속-토크 밴드를 고려한 DTC-PWM 제어 방식 (DTC-PWM control method of PMSM using the flux-torque Band)

  • 김승준;박준휘;김지원;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.63-65
    • /
    • 2018
  • This paper presents a DTC-PWM(Direct Torque Control-Pluse Width Modulation) method of PMSM(Permanent Magnet Synchronous Motor) using the flux-torque hysteresis band. In order to keep the flux and torque error of the PMSM within the hysteresis band, the optimal PWM duty ratio is calculated by the error of the flux and torque with the flux and torque vector of the selected voltage vector. According to the flux duty ratios and the torque duty ratios, the optimized duty ratio to reduce the errors is selected by the calculated duty ratios. In the proposed method, the selected voltage vector is divided into d-q axis components with a simple method. And the flux duty ratios and torque duty ratios are estimated by the applied voltage vector. The proposed DTC-PWM for PMSM was verified by computer simulation.

  • PDF