• Title/Summary/Keyword: Synchronization Test

Search Result 165, Processing Time 0.027 seconds

Equalization Digital On-Channel Repeater Part 1 : Laboratory Test Results (등화형 디지털 동일 채널 중계기 Part 1 : 실험실 테스트 결과)

  • Park Sung Ik;Lee Yong-Tae;Eum Homin;Seo Jae Hyun;Kim Heung Mook;Kim Seung Won;Lee Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.210-220
    • /
    • 2005
  • This paper presents and analyzes laboratory test results of Equalization Digital On-Channel Repeater (EDOCR) using ATSC(Advanced Television Systems Committee) terrestrial digital TV broadcasting system. The EDOCR laboratory test, which is done at CRC(Communications Research Centre) Canada, is classified to receiver test, transmitter test, and synchronization test between transmission and reception frequencies. The receiver part includes feedback signal, random noise, single echo, multi-path ensemble, and NTSC/DTV interference test. The transmitter part includes out-of channel emission, quality of transmitting signal, and phase noise test. By the field test results, the receiver part of the EDOCR eliminates average 5.5 dB of feedback or single echo signal in range of 0 to 11 ${\mu}s$ and has average 18.6 dB at TOV(Threshold of Visibility) under random noise environment. Also, the transmitter part of the EDOCR satisfies the specification of US FCC(Federal Communications Commission), and frequency difference between transmitter and receiver is zero.

Distributed Translator Part 2: Laboratory Test Results (분산 중계기 Part 2: 실험실 테스트 결과)

  • Park, Sung-Ik;Eum, Ho-Min;Seo, Jae-Hyun;Kim, Heung-Mook;Lee, Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2010
  • This paper presents and analyzes laboratory test results of distributed translator (DTxR) for distributed frequency network (DFN) in the ATSC (Advanced Television Systems Committee) terrestrial digital TV broadcasting system. The DTxR laboratory test is classified to receiving part test and transmitting part test. The receiving part test includes dynamic range, random noise, single echo, and adjacent channel interference. The transmitting part test includes quality of output signal (out-of channel emission, quality of transmitting signal, and phase noise), frequency synchronization among output signals, and TxID (Transmitter Identification) signal's affect to the legacy receiver. By the laboratory test results, the receiving part of DTxR eliminates average -2.5 dB of single echo and has average 17.5 dB at TOV (Threshold of Visibility) under random noise environment. In addition, the transmitting part of DTxR satisfies the specification of US FCC (Federal Communications Commission), and frequency difference among DTxR output signals is less than 0.001 Hz.

The Geolocation Estimation System for a Stationary Emitter using Rotating Antenna (회전안테나를 이용한 고정 신호원 위치탐지 시스템)

  • Kwak, Hyungyu;Kim, Sangwon;Choi, Daegyu
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.681-689
    • /
    • 2016
  • In the direction and location finding field of application, AOA, TDOA and FDOA, etc. are used to improve the performance of geolocation. But, these methods cause some limitations such as the calibrations for phase and amplitude matching and precise time synchronization among receiving channels. In this paper, We suggest a method for generating FDOA using rotating antenna and the geolocation of stationary emitter using two receivers in one platform for minimizing the limitations. We present performance of simulation results and test results of the FDOA geolocation system. The direction finding errors of the system are less than $0.1^{\circ}$ rms and the distance errors are less than 3 % compared with the practical distance.

Synchronous 2D/3D Switching System for Service-Compatible 3DTV Broadcasting

  • Kim, Sangjin;Jeon, Taehyun
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.271-279
    • /
    • 2014
  • This paper proposes a new broadcasting system for the service-compatible 3DTV in which the 3D service can coexist with the conventional digital TV broadcast. In the proposed system, the commercial 3DTV service can be implemented via the existing DTV channel without utilizing the dedicated 3DTV system. This 2D/3D system interworks with the conventional system and can switch to 2D or 3D service according to the broadcast programming and schedule. The system also provides a mechanism that can prevent the synchronization mismatch between left and right video streams and between the stream and the associated signaling in the 2D/3D transition periods. The picture quality measurements are carried out based on the ITU-R recommended test to check the level of quality of service provided by the proposed scheme. The conformity tests are also performed with the conventional channel and the receiver for the DTV system to confirm the feasibility of the proposed one for the commercial service.

Performance Evaluation of a CONWIP System with Compound Poisson Demands and Coxian Processing Times (복합포아송 수요와 Coxian 가공시간을 갖는 CONWIP 시스템의 성능평가)

  • 박찬우;이효성
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.31 no.3
    • /
    • pp.63-79
    • /
    • 2006
  • In this study we consider a CONWIP system in which the processing times at each station follow a Coxian distribution and the demands for the finished products arrive according to a compound Poisson process. The demands that are not satisfied immediately are either backordered or lost according to the number of demands that exist at their arrival Instants. For this system we develop an approximation method to calculate performance measures such as steady state probabilities of the number of parts at each station, proportion of lost demands and the mean number of backordered demands. For the analysis of the proposed CONWIP system, we model the CONWIP system as a closed queueing network with a synchronization station and analyze the closed queueing network using a product-form approximation method. A recursive technique is used to solve the subnetwork in the application of the product-form approximation method. To test the accuracy of the approximation method, the results obtained from the approximation method are compared with those obtained by simulation. Comparisons with simulation show that the approximation method provides fairly good results.

Development and application of a vision-based displacement measurement system for structural health monitoring of civil structures

  • Lee, Jong Jae;Fukuda, Yoshio;Shinozuka, Masanobu;Cho, Soojin;Yun, Chung-Bang
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.373-384
    • /
    • 2007
  • For structural health monitoring (SHM) of civil infrastructures, displacement is a good descriptor of the structural behavior under all the potential disturbances. However, it is not easy to measure displacement of civil infrastructures, since the conventional sensors need a reference point, and inaccessibility to the reference point is sometimes caused by the geographic conditions, such as a highway or river under a bridge, which makes installation of measuring devices time-consuming and costly, if not impossible. To resolve this issue, a visionbased real-time displacement measurement system using digital image processing techniques is developed. The effectiveness of the proposed system was verified by comparing the load carrying capacities of a steel-plate girder bridge obtained from the conventional sensor and the present system. Further, to simultaneously measure multiple points, a synchronized vision-based system is developed using master/slave system with wireless data communication. For the purpose of verification, the measured displacement by a synchronized vision-based system was compared with the data measured by conventional contact-type sensors, linear variable differential transformers (LVDT) from a laboratory test.

Burst Mode Symbol Timing Recovery for VDL Mode-2 (VDL Mode-2에 적용 가능한 버스트 모드 심벌 타이밍 복원기)

  • Gim, Jong-Man;Choi, Seung-Duk;Eun, Chang-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.337-343
    • /
    • 2009
  • In this paper, we proposed a burst mode symbol timing recovery unit that is applicable to the VDL Mode-2 using D8PSK modulation. A method that IIR loop filter is used to minimize symbol timing error is hard to apply to burst mode because its convergence time is long. That is, the fast convergence property is important. In this paper, the proposed method takes one sample which has maximum symbol power after the initial synchronization has been achieved by using preambles. The main principle of operation is that the unit moves one sample clock to advance or retard according to symbol power. We verify that the proposed method is operated well in ${\pm}100$ ppm or greater through the test results between Australia ADS Corp. transmitter and the designed receiver.

  • PDF

Development of X-ray PIV System Using a Medical X-ray Tube (임상용 X-선관을 이용한 X-ray PIV시스템의 개발)

  • Yim, Dae-Hyun;Kim, Guk-Bae;Kim, Do-Il;Lee, Hyong-Koo;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.403-406
    • /
    • 2006
  • A new medical X-ray PIV technique was developed using a conventional medical X-ray tube. To acquire images of micro-scale particles, the X-ray PIV system consists of an x-ray CCD camera with high spatial resolution, and a X-ray tube with small a focal spot. A new X-ray exposure control device was developed using a rotating disc shutter to make double pulses which are essential for PIV application. Synchronization methodology was also developed to apply the PIV technique to a conventional medical X-ray tube. In order to check the performance and usefulness of the developed X-ray PIV technique, it was applied to a glycerin flow in an opaque silicon tube. Tungsten particles which have high X-ray absorption coefficient were used as tracer particles. Through this preliminary test, the spatial resolution was found to be higher than ultrafast MRI techniques, and the temporal resolution was higher than conventional X-ray PIV techniques. By improving its performance further and developing more suitable tracers, this medical X-ray PIV technique will have strong potential in the fields of medical imaging or nondestructive inspection as well as diagnosis of practical thermo-fluid flows.

  • PDF

Design of Synchronization_Word Generator in a Bluetooth System (블루투스 동기워드 생성기의 구현)

  • Hwang, Sun-Won;Cho, Sung;Ahn, Jin-Woo;Lee, Sang-Hoon;Kim, Seong-Jeen
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.214-217
    • /
    • 2003
  • In this paper, we deal with implementing design for a correlator access code generator module which they are used for setting up a connection between units, a packet decision, a clock syncronization, by FPGA. The orrelator module which is composed of the Wallace Tree's CSA and threshold value decision device decides useful a packet and syncronizes a clock, after it correlates an input signal of 1 Mbps transmission rate by a sliding window. An access code generator module which is composed of a BCH (Bose-Chadhuri-Hocquenghem) cyclic encoder and control device was designed according as a four steps' generation process proposed in the bluetooth standard. The pseudo random sequence which solves syncronization problem saved a voluntary device Proposed the module was designed by VHDL. An simulation and test are inspected by Xilinx FPGA.

  • PDF

An Adaptive Buffering Method for Practical HTTP Live Streaming on Smart OTT STBs

  • Kim, Hyun-Sik;Kim, Inki;Han, Kyungsik;Kim, Donghyun;Seo, Jong-Soo;Kang, Mingoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.3
    • /
    • pp.1416-1428
    • /
    • 2016
  • In this paper, we address the channel zapping time problem of video streaming services based on HTTP Live Streaming (HLS) on smart Over-The-Top Set-Top Boxes (OTT STBs). Experimental analysis of the channel zapping time, show that smart OTT STBs inevitably suffer from the accumulated zapping time through channel change request, Internet Group Management Protocol (IGMP) leave/join, synchronization delay, video buffer delay, and STB processing delay when providing HLS services. As a practical solution for the zapping time reduction, an adaptive buffering method is proposed. The proposed method exploits two adaptive buffers added to the basic HLS player. These two adaptive buffers are responsible for constantly buffering previous and next channels relative to the current channel. Implementation and test results show that a stable zapping time less than one second can be achieved even under diverse video bitrate changes and varying network conditions by the proposed adaptive buffering method.