• Title/Summary/Keyword: Symmetric Load

Search Result 226, Processing Time 0.026 seconds

Reinforcement Method of a Long Span Plastic Greenhouse using Tension-tie (인장타이를 이용한 광폭형 비닐하우스의 보강법)

  • Shin, Kyung-Jae;Shin, Dong-Hui;Lee, Swoo-Heon;Chae, Seoung-Hun
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • A long-span (more than 8m) plastic greenhouse is currently being used in farms due to its magnified benefits, such as the convenience of the farming equipment used, and the land usage efficiency. In this study, the reinforcing effects of the use of a pretension tie were shown. In a previous study, tests for a 6.5m single-span-type greenhouse announced by Rural Development Administration were carried out. The tests of symmetric and eccentrics now loading by the sun and wind were conducted for the 10.2m span with a ${\phi}48.1{\times}2.1$ section in this study, after which the load-deflection relationship was compared for the cases of reinforcement with a tie and without a tie. The results of the symmetric snow loading test showed that the strength increased by 68~93% in the case of the specimen with a tied arch. The failure mode of the specimen without a tie tended to be that with a sway failure mechanism, and that of the reinforcement specimens with a tie tended to be that with an arch buckling mechanism. The results of the eccentric snow loading test showed that the strength of the specimen with a tie increased by 10~20% compared to that of the specimen without a tie. For the failure mode of the latter, a combined failure mechanism was adapted, although the failure mode of the tied specimens tended to be that with an arch buckling mechanism.

Psychophysical and Physiological Study on Various Lifting Tasks (여러 가지 들기 작업에서의 인체심리학적 · 생리학적 연구)

  • Yun, Hun-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.11-22
    • /
    • 2006
  • The muscular-skeletal disorders(MSDs) that have become a major issue recently in Korean industrial safety area are mainly caused by manual material handling task. The objective of this study is to provide scientific data for the establishment of work safety standard for Korean workers through the experiments of lifting task under various conditions, in order to prevent the muscular-skeletal disorders in the industrial work site. Eight male college students were recruited as participants. Three different lifting frequencies(1, 3, 5 lifts/min) and three twisting angles(including the sagittal plane and two asymmetric angles; i.e., 0°, 45°, 90°) for symmetric and asymmetric tasks, respectively, with three lifting range from floor to knuckle height, knuckle to shoulder, floor to shoulder height for one hour's work shift using free style lifting technique were studied. The maximum acceptable weight of load(MAWL) was determined under the different task conditions, and the oxygen consumption, heart rate, and RPE were measured or recorded while subjects were lifting their MAWLs. The results showed that: (1) The MAWLs were significantly decreased as the task frequency and task angle increased.; (2) The heart rate, oxygen consumption, RPE significantly increased with an increase in lifting frequency although maximum acceptable weight of lift decreased.; (3) The highest heart rate and oxygen consumption was recorded at the lifting range of floor to shoulder, followed by floor to knuckle and knuckle to shoulder.; (4) The RPE value showed that subjects perceived more exertion at the high frequency rate of lifting task and lifting range of floor to shoulder height. (5) The modeling for MAWL using isometric strength, task angle and lifting frequency were developed. It is expected that use of the results provided in this study may prove helpful in reducing MMH hazards, especially from lifting tasks for Korean, and can be used as a basis for pre-employment screening.

Analysis of submerging characteristics and stability of the model submersible fish cage operated by buoyancy control (부력 제어식 가두리 모형의 부침 특성 및 안정성 해석)

  • Lee, Gun-Ho;Cha, Bong-Jin;Jeong, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.40-50
    • /
    • 2012
  • This study aims to analyze the performance of a submersible fish cage which was designed for developing an economical cage system can be applied in korean aquaculture environment easily. To analyze the performance of the designed cage a model test was carried out. In the test, inclination changes of the upper frame and mooring tensions of model cage were measured during the submerging and surfacing motion in still water and wave condition (period: 2s, wave height: 0.1, 0.2, 0.3m). As a result, in the still water condition the model cage kept horizontal balance and inclination degree of the upper frame was about $1^{\circ}$. In the wave condition, the model cage showed bilateral symmetric up-and-down motion but the average inclination degree of the upper frame was about $0^{\circ}$. When the model cage reached at a depth of 1m, the up-and-down motion of the cage was decreased by 12% compared with that of at the surface (period 2s, height 0.3m). In the same wave condition, the maximum and average line tension under the bottom position were about 8% and 11% respectively compared with that of at surface.

Design of High Speed Tensile Test Machine for Flow Stress under Intermediate Strain Rate Condition (중변형률 속도 유동응력 확보를 위한 고속 인장 실험기 설계)

  • Choung, Joonmo;Yoon, Sung-Won;Park, Sung-Ju;Kim, Younghun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.34-44
    • /
    • 2015
  • A hydraulic tensile test machine (HSTM) is one of the devices used to obtain the flow stress of a material during high-speed elongation. This paper first describes some features of a newly built HSTM. The improvement histories of the upper and lower jigs, which are the most vital parts of the HSTM, are also presented. We have frequently witnessed test failures with 1st generation jigs and specimens due to slip between the jig and specimen. 2nd generation jigs provide more stable test results, but the use of a longer upper jig induces excessive vibration and consequently makes it difficult to attach an environment chamber. 3rd generation jigs have some advances in terms of the symmetric fastening between the upper jig and specimen, as well as an exemption from direct contact between the lower jig and specimen. The performance of an environment chamber is verified by high and low temperature tests. A high-speed displacement measurement system is introduced based on a high-speed camera and motion-tracking software with aid of a surface grid device for the specimen.

Development of a Parallel Cell-Based DSMC Method Using Unstructured Meshes (비정렬격자에서 병렬화된 격자중심 직접모사 기법 개발)

  • Kim, Hyeong-Sun;Kim, Min-Gyu;Gwon, O-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.1-11
    • /
    • 2002
  • In the present study, a parallel DSCM technique based on a cell-based data structure is developed for the efficient simulation of rarefied gas flows especially od PC clusters. Dynamic load balancing is archieved by decomposing the computational domain into several sub-domains and accounting for the number of particles and the number cells of each domain. Mesh adaptation algorithm is also applied to improve the resolution of the solution and to reduce the grid dependency. It was demonstrated that accurate solutions can be obtained after several levels of mesh adapation starting from a coars initial grid. The method was applied to a two-dimensioanal supersonic leading-edge flow and the axi-symmetric Rothe nozzle flow to validate the efficiency of the present method. It was found that the present method is a very effective tool for the efficient simulation of rarefied gas flow on PC-based parallel machines.

The Study of Transmission Speed Analysis In Multimedia Access Network by Environmental Variation (단말의 환경변수에 의한 멀티미디어 가입자망의 전송속도 분석에 관한 연구)

  • Kim, Hyoung-Bae;Park, In-Jung;Chae, Soo-Ik;Park, Dong-Sun;Song, Sang-Seob;Lee, Jae-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.7
    • /
    • pp.1-5
    • /
    • 2001
  • This study accomplish comparison and analysis multimedia access network speed configuration which is effected by different environmental variation. For this testing. Not only LAN configuration which is symmetric network, But also the ADSL which is asymmetric network is tested by network speed checking software which is designed by our lab in a 10BaseT environment. In the case of TCP receive speed, we find out the network speed is changed according to bands of network to 90% of CPU load. Also, If the TCP receive windows's size became 2 times rate more than MTU, it reduced the relation of speed rate.

  • PDF

EFFECTS OF BONE ENGAGEMENT TYPE&IMPLANT LENGTH ON STRESS DISTRIBUTION: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS (임플란트 매식조건에 따른 상, 하악골의 응력분포 양상에 대한 3차원 유한요소분석 연구)

  • Choi, Jeong-Hwa;Seo, Ki-Youl;Choi, Joo-Ho;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.687-697
    • /
    • 1999
  • A finite element analysis has been utilized to analyze stress and strain fields and design a new configuration in orthopedics and implant dentistry. Load transfer and stress analysis at implant bone interface are important factors from treatment planning to long term success. Bone configuration and quality are different according te anatomy of expecting implantation site. The purpose of this study was to compare the stress distribution in maxilla and mandible accord-ing to implant length and bone engagement types. A three dimensional axi-symmetric implant model(Nobel Biocare, Gothenburg, Sweden) with surrounding cortical and cancellous bone were designed to analyze the effects of bone engagement and implant length on stress distribution. ANSYS 5.5 finite element program was utilized as an interpreting toot. Three cases of unicortical anchorage model with 7, 10, 13 mm length and four cases of bicortical anchorage model with 5, 7, 10 and 13 mm length were compared both maxillary and mandibular single implant situation. Within the limits of study, following conclusions were drawn. 1. There is a difference in stress distribution according to cortical and cancellous bone thickness and shape. 2. Maximum stress was shown at the top of cortical bone area regardless of bone engagement types. 3. Bicortical engagement showed less stress accumulation when compared to unicortical case overall. 4. Longer the implant future length, less the stress on cortical bone area, however there is no difference in mandibular bicortical engagement case.

  • PDF

Three Phase Embedded Z-Source Inverter (3상 임베디드 Z-소스 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

Design of the 1.9-GHz CMOS Ring Voltage Controlled Oscillator using VCO-gain-controlled delay cell (이득 제어 지연 단을 이용한 1.9-GHz 저 위상잡음 CMOS 링 전압 제어 발진기의 설계)

  • Han, Yun-Tack;Kim, Won;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.4
    • /
    • pp.72-78
    • /
    • 2009
  • This paper proposes a low phase noise ring voltage controlled oscillator(VCO) with a standard $0.13{\mu}m$ CMOS process for PLL circuit using the VCO-gain-controlled Delay cell. The proposed Delay cell architecture with a active resistor using a MOS transistor. This method can reduced a VCO gain so that improve phase noise. And, Delay cell consist of Wide-Swing Cascode current mirror, Positive Latch and Symmetric load for low phase noise. The measurement results demonstrate that the phase noise is -119dBc/Hz at 1MHz offset from 1.9GHz. The VCO gain and power dissipation are 440MHz/V and 9mW, respectively.

The Effects of Asymmetric Bag Carrying during Walking on Plantar Pressure (보행 시 비대칭성 가방 휴대가 족저압에 미치는 영향)

  • Park, Soo-Jin;Lee, Jung-Ho;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.4
    • /
    • pp.459-469
    • /
    • 2012
  • PURPOSE: The purpose of the present study was to examine changes caused by asymmetric bag carrying methods to carry the bag with one shoulder only to plantar pressure during walking. METHODS: Twenty three normal adults without any gait problem participated in the present study. Experimental conditions used consisted of walking without carrying any bag(condition 1), walking wearing a bag on both shouders (condition 2), and walking wearing a bag on the right shoulder(condition 3) and the weight of the bag was set to 15% of each subject's body weight. All the subjects were instructed to participate in all experiments under these three conditions and plantar pressures were measured from the subjects' right and left feet using an F-scan system while the subjects were walking under the three conditions. To analyze the measured plantar pressure, the sole was divided into seven areas (Hallux, Toe, Met1, Met23, Met45, Mid foot and Heel) and maximum plantar pressures in individual areas were measured. RESULTS: The results of measurement of plantar pressures under three walking conditions did not show significant changes in any areas of the left and right feet except for the mid foot area of the right food. The asymmetry between the left and right feet was examined and the results showed significant differences only in area Met23 under condition 2 and did not show significant differences in any other areas. CONCLUSION: On comprehensively considering the results of the present study, it could be seen that asymmetric bag carrying did not have large effects on changes in plantar pressure during walking compared to symmetric carrying. The reason for this is considered to be posture adjusting mechanisms against load positions.