• 제목/요약/키워드: Switching power

검색결과 4,316건 처리시간 0.039초

소프트 스위칭 방식의 새로운 DC-DC 컨버터에 관한 연구 (A Study on The Novel Soft Switching DC-DC Converter)

  • 이봉준;안태영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.332-336
    • /
    • 2003
  • In this paper, we report the experimental results of the novel Soft-Switching DC-DC converter and synchronous rectifier The experimental converter, that has a output voltage 3.3V, output current 20A, maximum power of 66W, switching frequency of 100kHz and input voltage range of 44-52V, has been successfully implemented. As a result, in the entire voltage range the measured full load efficiency was above 90$\%$, and the output voltage was regulated at 3.3V within ${\pm}3{\%}$ tolerance.

  • PDF

ZCS 보조회로를 이용한 ZVT Boost 컨버터에 관한 연구 (A Study on ZVT Boost Converter Using a ZCS Auxiliary Circuit)

  • 류동균;이우석;최태영;서민성;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 2001
  • Recently, a ZVT boost converter is embedded in a power factor correction system. The control circuit of the converter assures soft-switching for all the MOSFETs and load regulation. The PFC system contains additional control circuits which assure the input voltage in a sinusoidal form and feed-forward line voltage regulation. In this paper, a soft switching boost converter with zero-voltage transition(ZVT) main switch using zero-current switching(ZCS) auxiliary switch is proposed. Operating intervals of the converter are persented and analyzed. The proposed results show that the main switch maintains UT while auxiliary switch retains ZCS for the complete specified line and load conditions.

  • PDF

ZVS 위상천이 풀브릿지 컨버터의 디지털 샘플링 기법에 따른 소신호 모델 분석 (An Analysis of ZVS Phase-Shift Full-Bridge Converter's Small Signal Model according to Digital Sampling Method)

  • 김정우;조영훈;최규하
    • 전력전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.167-174
    • /
    • 2015
  • This study describes how digital time delay deteriorates control performance in zero voltage switching (ZVS) phase-shifted full bridge (PSFB) converter. The small-signal model of the ZVS PSFB converter is derived from the buck-converter small-signal model. Digital time delay effects have been considered according to the digital sampling methods. The analysis verifies that digital time delays reduce the stability margin of the converter, and the double sampling technique exhibits better performance than the single sampling technique. Both simulation and experimental results based on 250 W ZVS PSFB confirm the validity of the analyses performed in the study.

PDM ZCS Resonant High Frequency Inverter for Induction Heated Roller

  • Kang, Shin-Chul
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents a lossless inductor snubber-assisted series resonant high frequency inverter using the trench gate IGBTs for the electromagnetic induction eddy current-heated fixing roller in copy and printing machines in a new generation. This soft switching high-frequency inverter can completely achieve zero current soft switching (ZCS) commutation mode transitions and wide power regulation under its constant frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally presented for a constant frequency PDM strategy under a ZCS operation, together with its output power regulation characteristics-based on the pulse density modulation. The effectiveness of this soft switching high-frequency inverter is confirmed for the fixing equipment with the induction-heated fixing roller.

전력전자 변환장치를 위한 고정 스위칭 주파수로 동작하는 3상 및 2상 변조 SRP-PWM기법 (3-Phase and 2-Phase Modulated SRP-PWM Technique with a Fixed Frequency for Power Electronics Converters)

  • 오승열;정영국;임영철;위석오
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.397-401
    • /
    • 2004
  • In this paper, Inverter drives adopting 3-phase and 2-phase SRP-PWM (Separately Randomized Pulse Position PWM) with fixed switching frequency is proposed. In the proposed SRP-PWM scheme, each of 3 or 2 phase pulses Is located randomly in each switching interval. The experimental results show that the voltage / current harmonics and the switching noise harmonics are spread to a wide band area. Also, the performance of the 3-phase SRP-PWM and the 2-phase SRP-PWM are compared to each other. In result, the speed response is nearly similar to each other from the viewpoint of the v/f constant control.

  • PDF

Stability Analysis and Control of Nonlinear Behavior in V2 Switching Buck Converter

  • Hu, Wei;Zhang, Fangying;Long, Xiaoli;Chen, Xinbing;Deng, Wenting
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1208-1216
    • /
    • 2014
  • Mismatch between switching frequency and circuit parameters often occurs in industrial applications, which would lead to instability phenomena. The bifurcation behavior of $V^2$ controlled buck converter is investigated as the pulse width modulation period is varied. Nonlinear behavior is analyzed based on the monodromy matrix of the system. We observed that the stable period-1 orbit was first transformed to the period-2 bifurcation, which subsequently changed to chaos. The mechanism of the series of period-2 bifurcations shows that the characteristic eigenvalue of the monodromy matrix passes through the unit circle along the negative real axis. Resonant parametric perturbation technique has been applied to prevent the onset of instability. Meanwhile, the extended stability region of the converter is obtained. Simulation and experimental prototypes are built, and the corresponding results verify the theoretical analysis.

무선 통신을 위한 고효율 CMOS 전력 증폭기 (High efficiency CMOS power amplifier for wireless applications)

  • 유창식
    • 한국통신학회논문지
    • /
    • 제26권10B호
    • /
    • pp.1475-1481
    • /
    • 2001
  • 무선 통신을 위한 전력 증폭기를 0.25$\mu\textrm{m}$ CMOS 공정으로 구현하였다. 전력 효율을 증가시키기 위하여 class-E 구조를 사용하여 soft-switching 특성을 활용하였다. Class-E 부하 회로의 DC-feed 인덕터는 유한한 값을 갖도록 하여 RF-choke을 사용하는 경우에 비해 동일한 전력과 공급 전압에 대해 필요로 하는 부하 저항의 크기를 증가시킴으로써 전력 효율을 더욱 증가시킬 수 있었다. 또한 common-gate switching 방법을 사용하여 기존의 switching 방법에 비해 허용되는 공급 전압의 크기를 두배 정도 증가시킬 수 있도록 하였다. 이러한 기법을 사용함으로써 900MHz의 주파수에서 공급 전압이 1.8V일 때 트랜지스터에 아무런 전압 stress를 가하지 않고 0.9W의 전력을 41%의 효율(power added efficiency, PAE)을 가지면서 50Ω 부하에 전달함을 확인하였다.

  • PDF

불연속 동작특성을 갖는 전력계통의 RCF법을 사용한 고유치 해석 : 상태천이 방정식으로의 모델링 (Eigenvalue Analysis of Power Systems with Non-Continuous Operating Elements by the RCF Method : Modeling of the State Transition Equations)

  • 김덕영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.67-72
    • /
    • 2005
  • In conventional small signal stability analysis, system is assumed to be invariant and the state space equations are used to calculate the eigenvalues of state matrix. However, when a system contains switching elements such as FACTS devices, it becomes non-continuous system. In this case, a mathematically rigorous approach to system small signal stability analysis is by means of eigenvalue analysis of the system periodic transition matrix based on discrete system analysis method. In this paper, RCF(Resistive Companion Form) method is used to analyse small signal stability of a non-continuous system including switching elements. Applying the RCF method to the differential and integral equations of power system, generator, controllers and FACTS devices including switching elements should be modeled in the form of state transition equations. From this state transition matrix eigenvalues which are mapped to unit circle can be calculated.

발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구 (A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant)

  • 권오규;이영삼
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1037-1040
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

An On-Line Harmonic Elimination Pulse Width Modulation Scheme for Voltage Source Inverter

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.43-50
    • /
    • 2010
  • This paper proposes a new harmonic elimination PWM (HEPWM) scheme for voltage source inverters (VSI) based on the curve fittings of certain polynomials functions. The resulting equations to calculate the switching angle of the HEPWM require only the addition and multiplication processes; therefore any number of harmonics to be eliminated and the fundamental amplitude of the pole switching waveform (NP1) can be controlled on-line. An extensive angle error analysis is carried out to determine the accuracy of the algorithm in comparison to the exact solution. To verify the workability of the technique, an experimental single phase VSI is constructed. The algorithm is implemented on a VSI using a 16-bit microprocessor. The results obtained from the test rig are compared to the theoretical prediction and the results of the MATLAB simulations.