• 제목/요약/키워드: Switching mode power supply

검색결과 183건 처리시간 0.025초

스위칭 모드 파워 서플라이 건전성에 대한 진단 (A Fault Diagnosis on the Switching Mode Power Supply)

  • 백승찬;이진호;오병주;이영훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.735-737
    • /
    • 2004
  • This paper proposes a method of fault diagnostics on switching mode power supply. When the error of switching mode power supply cannot be found when the conventional diagnostics is performed, this proposed method first performs diagnosis on the switching mode power supply strictly to judge the operating condition. This method analyzes the PWM wave which depends on the load change, to make sure the feedback control of the power supply to diagnosis the operation of the power supply system.

  • PDF

스위칭전원을 이용한 자기신경자극기 (The Magnetic Nerve Stimulator Using a Switching Mode Power Supply)

  • 이수열;이성근;이정한
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.265-270
    • /
    • 1995
  • An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for chArging high voltage cApacitors, the weight and size of the magnetic net've stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec Experimental results of human nerve stimulations using the developed stimulator are presented.

  • PDF

Mode Switching Smooth Control of Transient Process of Grid-Connected 400 Hz Solid-State Power Supply System

  • Zhu, Jun-Jie;Nie, Zi-Ling;Zhang, Yin-Feng;Han, Yi
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2327-2337
    • /
    • 2016
  • The mode-switching control of transient process is important to grid-connected 400 Hz solid-state power supply systems. Therefore, this paper analyzes the principle of on-grid and islanding operation of the system with or without local loads in the grid-connected process and provides a theoretical study of the effect of different switching sequences on the mode-switching transient process. The conclusion is that the mode switch (MS) must be turned on before the solid-state switch (STS) in the on-grid process and that STS must be turned off before the MS in the off-grid process. A strategy of mode-switching smooth control for transient process of the system is proposed, including its concrete steps. The strategy utilizes the average distribution of peak currents and the smooth adjustment of peak currents and phases to achieve a no-shock grid connection. The simulation and experimental results show that the theoretical analysis is correct and that the method is effective.

디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법 (Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display)

  • 이재원;전태원
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

FNS를 사용한 하반신마비자의 일어서기 (Functional Neuromuscular Stimulation for Paraplegic Standing)

  • 강곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.1-4
    • /
    • 1990
  • Functional neuromuscular stimulation(FNS)를 사용하여 하반선마비사가 앉은 상태에서부터 일어나 균형을 유지할 수 있도록 하기 위하여 FNS의 자동제어 시스댐을 개발하였다. Output feedback gain matrix를 최적제어이론을 사용하여 계산하기 위하여 비선형 선체모델을 직립위치에 대하여 선형화하였다. 제어기는 측정된 output에 의하여 매순간 각 선체조인트에 필요한 torque할 계산 하며, 이 조인트 torque는 근육이 최소한의 에너지를 사용하게끔 각 단육에 배분된다. 컴퓨터 시뮬레이션결과, 이 제어 시스템을 사용하여 각 조인트가 약 45도 정도 구부버진 상태에서 부터 직립위치를 회복할 수 있으며 팔의 움직임으로 대표되는 외부로부터의 방해를 반았블 때에도 직립 위치를 자동적으로 유지할 수 있었다.

  • PDF

스위칭 모드 직류 전원공급기(SMPS)의 전도성 잡음해석 (Conducted Noise Analysis of SMPS(Switching Mode Power Supply))

  • 성주영;김윤명
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2000년도 종합학술발표회 논문집 Vol.10 No.1
    • /
    • pp.286-291
    • /
    • 2000
  • 본 논문에서는 일반적인 EMI 노이즈 개요 및 SMPS(Switching Mode Power Supply)에서의 Noise 발생 메카니즘을 분석하고, 전도성 Noise를 측정하였으며, SMPS에서 발생되는 잡음행태를 분석하여 대책방법을 연구하였다.

  • PDF

Design for reduction EMI of flyback switching power supply

  • Theirakul, Chaivat;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1891-1895
    • /
    • 2003
  • Switch-mode power supplies (SMPS) have become a major source of conducted electromagnetic interference (EMI) which is the combination between differential mode (DM) noise and common mode (CM) noise. This paper presents the conducted EMI reduction approach in flyback switched mode power supply by rerouting for circuit balance to reduce common mode noise. And differential mode noise can be reduce by adding $c_x$ capacitor across the input power line, and passive element to the gate drive of switching device MOSFET to slow down the switching times. This combination of our approach is the effective way to reduce the conducted EMI and it is also a cost effective for product design

  • PDF

새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구 (A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator)

  • 곽아림;박성미;손경종;박성준;김종철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

통신장비 시험용 Switching Power Supply 개발에 관한 연구 (A Study on the Development of Switching Power Supply for testing communication equipment)

  • 배진용;김용;권순도;한경태;이동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.253-257
    • /
    • 2003
  • This paper presents the Development of Switching Power Supply for testing communication equipment. The communication equipment need many kinds of voltage(-48V,27V,12V,5V,3.3V), and in case of low voltage needs large current($10{\sim}20A$). The previous Linear Power Supply was very heavy, has low efficiency and poor power-factor for testing communication equipment. This development has good efficiency and high power-factor using switch mode power supply technique. This Development of Switching Power Supply is composed of eight converters. The principles of operation, feature, and design considerations are illustrated and verified through the experiment with 600W prototype.

  • PDF

Two Switches Balanced Buck Converter for Common-Mode Noise Reduction

  • Kanjanasopa, Warong;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.493-498
    • /
    • 2004
  • The EMI noise source in a switching mode power supply is dominated by a common mode noise. If we can understand the common mode noise occurring mechanism, it is resulted to find out the method to suppress the EMI noise source in the switching mode power supply. The common mode noise is occurring mostly due to circuit is unbalanced which is caused by the capacitive coupling to frame ground, which passes through a heatsink of the switching devices. This research paper presents a new effective balancing method of buck converter circuit by mean of grounding the parasitic and compensation capacitors in correct proportion which is called that the common mode impedance balance (CMIB). The CMIB can be achieved by source, transmission line and termination balanced, such balancing, the common mode current will be cancelled out in the frame ground. The greatly reduced common mode noise can be confirmed by the experimental results.

  • PDF