• Title/Summary/Keyword: Switching characteristics

Search Result 1,837, Processing Time 0.029 seconds

A Study on Factors Affecting Vender's Continuous Use Intention in O2O Delivery App Platform Service (O2O 배달 앱 플랫폼 서비스에서 공급 업체의 지속이용의도에 영향을 미치는 요인에 관한 연구)

  • Lee, Jae Kwang;Choi, Youngwoo;Lim, Eunju;Kim, Yoomin;Ahan, Saerom;Kim, Minjeong
    • Journal of Information Technology Services
    • /
    • v.20 no.2
    • /
    • pp.13-31
    • /
    • 2021
  • Recently, delivery app services based on the O2O platform are increasing rapidly. Accordingly, various studies on O2O service have been conducted. Most of the studies are on consumer behavior in O2O services, and few studies on platform vendors have been conducted. Therefore, this study empirically analyzed the factors affecting the vender's intention to continuous use in the O2O delivery app platform service. Based on prior researches, we set the quality characteristics and network characteristics of the O2O platform as independent variables. The quality characteristics of the O2O platform consisted of system quality, information quality, and service quality, and the O2O platform network characteristics consisted of network externality and platform reputation. Perceived value and switching cost were set as mediated variables, and vender's intention to continuous use was set as dependent variables. For empirical analysis, we conducted a survey targeting vendors of O2O delivery app platform service, and conducted frequency analysis, factor analysis, reliability analysis, and regression analysis. As a result of the analysis, the quality characteristics of the O2O platform, such as system quality, information quality, service quality, and O2O platform network characteristics, showed that network externality and platform reputation had a positive effect on perceived value. The perceived value was found to have a positive effect on the switching cost and the intention to continuous use, and the switching cost was found to mediate the perceived value and the intention to continuous use. This study can contribute to the establishment of platform operation strategy as an empirical analysis on the factors that influence the intention of O2O platform vendors to use the platform continuously.

Effects of Customer Satisfaction and Switching Barrier on Customer Retention and Intention of WOM in Insurance Services (보험서비스에서 고객만족과 전환장벽이 고객유지와 구전의도에 미치는 영향)

  • Jung, Duk-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.7
    • /
    • pp.344-354
    • /
    • 2010
  • The primary purpose of this study is to examine the effects of customer satisfaction and switching barrier on customer retention and intention of WOM in insurance services. Based on relevant literature reviews, this study posits three switching barrier characteristics, that is, switching costs, attractiveness of alternatives and interpersonal relationship as key determinants of customer retention and intention of WOM. And then we structured a research model and hypotheses about relationship between these variables. A total 230 usable survey responses of life insurance service users have been employed in the analysis. The major findings from the data analyses are as follows. Firstly, customer satisfaction had a positive influence upon customer retention and intention of WOM. Secondly, two switching barrier characteristics of switching costs and interpersonal relationship had a positive influence upon customer retention. Lastly, customer retention had very significantly related to intention of WOM in insurance services. From this study, we expect to suggest practical and managerial implications to insurance service providers.

The Study on the Characteristics of the Load Sharing in SRM with the Parallel Operation of Phase Winding (병렬권선 운전시 SRM의 부하분담 특성에 관한 연구)

  • Lee, Sang-Hun;Park, Sung-Jun;Choi, Cheol;Ahn, Jin-Woo;Kim, Cheul-U
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.30-39
    • /
    • 2003
  • In SRM driving, the current rate is directly related to the rate of switching device and in cost reduction, the Parallel switching operation is the alternatives because it has the smaller current rate through current division. There ire many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. The reason Is that the switching characteristics are mainly relied on the different saturation voltage of each device etc. and these factors are not altered by a circuit designer. In order to compensate this problem, a proper resistance is experimently inserted to the switching device. But this method can not be the optimal solution. Therefore this paper propose a new parallel operation of SRM which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. Also the reliable and stable driving is improved through experiments and the detailed principles.

The Modifying Effect of Switching Barriers in Customer Loyalties in Medical Services (의료서비스에서 고객충성도에 대한 전환장벽의 조절효과 분석)

  • Lee, Sun-Hee;Kim, Hyun-Mi;Chae, Yoo-Mi
    • Health Policy and Management
    • /
    • v.17 no.3
    • /
    • pp.68-86
    • /
    • 2007
  • This study was performed to explore the effect of customer satisfaction and switching barriers on customer royalties in medical services. 900 households, 1% sample were randomly selected from K city located in Kangwon province. Interview survey was performed with structured questionnaire for the entire people, 923 persons who experienced medical service utilization during one year before survey on time, september, 2002. In comparison of switching barriers by sociodemographic characteristics, lower income group and lower educated group showed the higher level of recognition level on availability of changing the service provider significantly. In terms of economic loss as one of switching barriers, the group of over aged 61, the lower income group and the lower educated group felt higher than other groups. Also, the time loss of switching barrier was recognized in 41-60 aged group and employee in service industry highly. For the perceived risk factor as another switching barrier, the high educated group showed the higher recognition level in performance risk and felt higher social risk than other groups. In analysis of customer satisfaction and loyalty levels by switching barrier components, the lower level of availability of changing the service provider and the higher level of recognition for economic and time loss, they showed the higher satisfaction and loyalty levels. In final step, multiple regression analysis showed the positive relationship between customer satisfaction, switching barrier and customer loyalties. Besides, the moderating effect of switching barrier in relationship between customer satisfaction and loyalties was significant and this results suggests that the influence of customer satisfaction to customer loyalties might be weakened in high level of recognition for switching barrier. In conclusion, perceived risk of economic and time loss as switching barrier is an important factor and should be considered in planning of marketing strategy carefully in terms of defensive marketing.

A New CMOS IC Package Design Methodology Based on the Analysis of Switching Characteristics (CMOS IC 패키지의 스위치 특성 해석 및 최적설계)

  • 박영준;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1141-1144
    • /
    • 1998
  • A new design methodology for the shortchannel CMOS IC-package is presented. It is developed by representing the package inductance with an effective lumpedinductance. The worst case maximum-simultaneous-switching noise (SSN) and gate propagation delay due to the package are modeled in terms of driver geometry, the maximum number of simultaneous switching drivers, and the effective inductance. The SSN variations according to load capacitances are investigated with this model. The package design techniques based on the proposed guidelines are verified by performing HSPICE simulations with the $0.35\mu\textrm{m}$ CMOS model parameters.

  • PDF

High-Efficiency Ballast for HID Lamp using Soft-Switching Multi-Level Inverter

  • Lee, Baek-Haeng;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.373-378
    • /
    • 2007
  • Soft switching was applied to the multi-level inverter to enhance the performance of the high-intensity discharge (HID) ballast used in vehicle headlights. The electrical properties were investigated and the available modeling of ballast in steady state was calculated using mathematical methods. The result was used in analyzing the power characteristics. The modeling was confirmed by the experiment.

Small-signal Analysis of the Full bridge ZVZCS converter (풀-브릿지 영전압 영전류 컨버터의 소신호 모델링)

  • Choi, Hang-Seok;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2518-2521
    • /
    • 1999
  • A Full-bridge zero-voltage zero-current switching (ZVZCS) converter using transformer auxiliary winding is analyzed. A complete small-signal model for the control scheme is developed. The propoed model is accurate up to half the switching frequency. The dynamic characteristics are compared with those of the zero-voltage switching converter and buck converter. Model predictions are confirmed by experimental measurements.

  • PDF

DC/DC Switching Converter Characteristics (DC/DC 스위칭 컨버터 특성)

  • 최영진;김상준;김태경
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.743-746
    • /
    • 1999
  • In this paper, Flyback type DC/DC Switching Converter was designed, analyzed and fabricated. Worst Case Analysis(WCA) was peformed with Mathcad program and presents circuit simulation results for the in-rush current limit circuit. The value of the maximum OFF voltage stress is 131.84V, it is less than device specification(200V). The switching frequency(nominal case) and duty cycle at the wont case analysis are 75KHz and 34.62%, respectively. The maximum in-rush current presents 0.5A Those results show a possibility for use in space

  • PDF

-A Study on the Switching Induction Noise Characteristic of A1 wiring Duct Using Taguchi Method- (다구찌 방법을 이용한 A1 배선덕트의 스위칭 유도노이즈 특성에 관한 연구)

  • 홍석묵;박명규
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.2
    • /
    • pp.199-214
    • /
    • 2003
  • With the progress of industrial technology, industrial machinery and home appliances have multi-function and high performances by the electronic control technology. Various results are given from the measuring switching induction noise according to environmental condition and its effects cannot be predicted accurately. Therefore, the output results should be analyzed and applied to practical work. To minimize the false operation, Taguchi Method used to solve the quality problem is adopted to analyze the characteristics within the constrained measuring level.

Traction IGBT Modules Design Issues and Precautions (전철용 IGBT 모듈 설계연구)

  • Gopal, Devarajan;Lho, Young-Hwan;Kim, Yoon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1853-1859
    • /
    • 2008
  • IGBT modules are designed for low loss, rugged for all environments and user friendly. Low on state saturation voltage with high switching speed is the primary concerns. In this paper selection of IGBT, module ratings and characteristics are discussed. The IGBT design topic of protection against over voltage and over current are covered. Emphasis on turn off switching, short circuit switching and necessary precautions are dealt. Selection of IGBT device, gate drive power, and its lay out considerations are covered in detail.

  • PDF