• 제목/요약/키워드: Switching Operation

검색결과 1,459건 처리시간 0.03초

유도가열용 ZCS PWM SEPP 고주파 인버터의 특성 (Character of Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;김칠용;곽동걸;김춘삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

유도가열용 ZCS PWM SEPP 고주파 인버터 (Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;권순걸;이종걸;주석민;강신출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

새로운 ZVS 소프트 스위칭 H-Bridge 인버터 (A Novel ZVS Soft-Switching H-Bridge inverter)

  • 최광수;정두용;김재형;이수원;원충연;정용채
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.130-132
    • /
    • 2008
  • In this paper, we have proposed a novel zero-voltage-switching (ZVS) soft-switching H-bridge inverter. Because the conventional H-Bridge inverter generates switching losses at turn on and off, the efficiency is reduced. The proposed inverter operates ZVS switching using an auxiliary switch and resonant circuit to improve the efficiency. in the DC-DC converter stage, it can reduce not only switching loss but also capacity and size of passive devices due to the resonant elements. DC-AC inverter stage supplies load with energy through the ZVS operation of 4 switches. A detail mode analysis of operating is in presented. We have presented the inverter topology, principle of operation and simulation results obtained from the PSIM simulator.

  • PDF

Model-based Optimal Control Algorithm for the Clamp Switch of Zero-Voltage Switching DC-DC Converter

  • Ahn, Minho;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.323-333
    • /
    • 2017
  • This paper proposes a model-based optimal control algorithm for the clamp switch of a zero-voltage switching (ZVS) bidirectional DC-DC converter. The bidirectional DC-DC converter (BDC) can accomplish the ZVS operation using the clamp switch. The minimum current for the ZVS operation is maintained, and the inductor current is separated from the input and output voltages by the clamp switch in this topology. The clamp switch can decrease the inductor current ripple, switching loss, and conduction loss of the system. Therefore, the optimal control of the clamp switch is significant to improve the efficiency of the system. This paper proposes a model-based optimal control algorithm using phase shift in a micro-controller unit. The proposed control algorithm is demonstrated by the results of PSIM simulations and an experiment conducted in a 1-kW ZVS BDC system.

액티브 공진 콘덴서를 이용한 소프트 스위칭형 PWM 전력변환기에 관한 연구 (A study on PWM power conversion system by soft switching type using active resonant condenser)

  • 곽동걸;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.174-176
    • /
    • 2003
  • The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. This paper proposes a skillful and a concise PWM DC-DC converter employing both zero voltage and zero current high frequency switching(ZVCS) operation. The Proposal ZVCS circuit is composed with resonant circuit using active resonant condenser. And this circuit provides switches with ZVS and ZCS by quasi resonant only that switching transients appear. This operation results in reduction of stress and losses in the power devices and resonant components. Some simulation results are included to confirm the validity of the analytical results.

  • PDF

SRM의 병렬권선 운전 특성 (Characteristics of Parallel Winding Drive of SRM)

  • 황형진;박성준;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.66-68
    • /
    • 2003
  • In a motor drive, the current rating is directly related to the rating of a switching device, and the parallel switching operation for a cost reduction is the alternatives because it has the smaller current rating through current division. There are many investigations for the parallel switching operations to equaling the current division. However it remains many problems for practical usage. This paper proposes a new parallel operation which uses a parallel phase winding to remove the traditional effect of switching device such as saturation voltage according to the division of current. The proposed strategy is verified by theoretical and experimental verification.

  • PDF

고장용량 감소를 위한 송전선 개방 운용에 신경회로망 적용 연구 (Neural Network Application to the T/L Operation for Suppression of Short Circuit Capacity)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.26-30
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the methods for wuppressing the short circuit capacity. This paper presents the T/L switching operation by using the Hopfield neural network(HNN). The switching of T/L can make the line powers and the bus voltages deteriorated, as well as the fault current decreased. Such an insecure state should be avoided when the T/L is operated to be open. In this studies, the inequality constraints are formulated into the objective function to be incorporated with the HNN. Test results show that the convergence characteristics of HNN lead to the adequate solution of T/L switching.

  • PDF

소프트 스위칭 모듈을 이용한 3상 고역률 컨버터 (A Three-Phase Converter with High Power Factor Using Soft-Switching Module)

  • 김재홍;정진규;백승택;한병문;김현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.663-666
    • /
    • 1999
  • This paper describes a three-phase converter with high power factor using a scheme of discontinuous current mode(DCM). The proposed system can replace the conventional diode bridge with step-up chopper which is used as a converter for adjustable speed drive. In this system, the current of reactor is zero at turn-on instance because of operation in DCM, while the switch turns off at the instance of maximum current. A soft-switching scheme with lossless snubber was proposed. Therefore, a zero-voltage switching at turn off can be achived by lossless snubber and zero-current switching at turn on can be obtained by operating under DCM. A theoretical analysis and computer simulations with PSpice were done to verify the operation of the proposed system. Also a prototype of hardware system was built and tested for verifying the feasibility of proposed system.

  • PDF

소프트 스위칭 방식의 보조 회로를 갖는 영전압 스위칭 부스트 컨버터 (ZVS Boost Converter with Soft Switching Auxiliary Circuit)

  • 송인범;박건욱;정두용;김동성;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.487-488
    • /
    • 2010
  • This paper proposes a soft switching boost converter with an auxiliary circuit. This circuit helps a main switch operate as a soft switching. The main switch operates ZVS turn-on and ZVS turn-off. And the auxiliary switch operates ZCS turn-on and ZVS turn-off. In this paper, operation modes are analyzed and soft switching operation is verified through simulations.

  • PDF

A High Efficiency and High Power Chopper Circuit QRAS using Soft Switching under Test Evaluation at 8kW

  • Tsuruta Yukinori;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This paper is a record of the study on a high efficiency and high power chopper based on the new soft switching method QRAS (Quasi~resonant Regenerating Active Snubber) designed for a Fuel Cell Electric Vehicle (FCEV). This power chopper is basically proposed for 25kHz soft switching. To confirm the practicality and effectiveness of the converter, the fabrication of a prototype-model using IGBTs was completed. Additionally, a 8kW rating test, a light load test, a current discontinuous mode test and a stable operation resonance test was completed. The circuit geometry, the basic operation, and the 8kW one-tenth-prototype test results are reported with a $97.5\%$ efficiency measurement.