• Title/Summary/Keyword: Switching Operation

Search Result 1,459, Processing Time 0.025 seconds

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

Analysis of a new Soft-Switching High-Frequency Inverter for High Current (대전류화를 위한 새로운 소프트 스위칭 고주파 인버터의 회로 해석)

  • Lee, E.Y.;Ra, B.H.;Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1187-1189
    • /
    • 2002
  • In the case of an existing high frequency inverter is became forced extinction by quick load change, due to be connected with series inductor on switch, it is destroyed or is generated conduction loss by resistance component in reactor. And, In the operation of high current with a soft switching, conduction loss can not neglect. In this paper, for the high current power source, we make sure of soft swtching operation and reducing surge when the forced extinction by using a connected switch with series inductor. Also, we poropos a topology of the half bridge type high frequency inverter that can be realized high amplitude operation of the load current. And, analyze the circuit to decide an opmtial circuit parameter.

  • PDF

Analysis, Design, Modeling, Simulation and Development of Single-Switch AC-DC Converters for Power Factor and Efficiency Improvement

  • Singh, Bhim;Chaturvedi, Ganesh Dutt
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2008
  • This paper addresses several issues concerning the analysis, design, modeling, simulation and development of single-phase, single-switch, power factor corrected AC-DC high frequency switching converter topologies with transformer isolation. A detailed analysis and design is presented for single-switch topologies, namely forward buck, flyback, Cuk, Sepic and Zeta buck-boost converters, with high frequency isolation for discontinuous conduction modes (DCM) of operation. With an awareness of modem design trends towards improved performance, these switching converters are designed for low power rating and low output voltage, typically 20.25W with 13.5V in DCM operation. Laboratory prototypes of the proposed single-switch converters in DCM operation are developed and test results are presented to validate the proposed design and developed model of the system.

A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP) (Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법)

  • Lee, Jun-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.239-242
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display Panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, the technique shows the minimum address power consumption according to various displayed images, different from Prior methods operating in fixed mode regardless of images. Test results with 50" HD single-scan PDP(resolution = 1366$\times$768) show that less than 350ns of recovery time is successfully accomplished and about 54% of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

Load-Adaptive Address Energy Recovery Technique for Plasma Display Panel

  • Lee Jun-Yeong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.192-200
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, th e technique shows the minimum address power consumption according to various displayed images, different from prior methods operating in fixed mode regardless of images. Test results with 50' HD single- scan PDP(resolution : $1366{\times}768$) show that less than 350ns of recovery time is successfully accomplished and about $54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

Selective Dual Duty Cycle Controlled High Frequency Inverter Using a Resonant Capacitor in Parallel with an Auxiliary Reverse Blocking Switch

  • Saha, Bishwajit;Suh, Ki-Young;Kwon, Soon-Kurl;Mishima, Tomokazu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.118-123
    • /
    • 2007
  • This paper presents a new ZCS-PWM high frequency inverter. Zero current switching operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. Dual duty cycle control scheme is used to provide a wide range of high frequency AC output power regulation that is important in many high frequency inverter applications. It found that a complete soft switching operation can be achieved even for low power setting ranges by introducing high-frequency dual duty cycle control scheme. The proposed high frequency inverter is more suitable for consumer induction heating(IH) applications. The operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

Novel Hybrid Converter for the On-Board Charger of Electric Vehicle (전기자동차용 온보드 충전기를 위한 새로운 하이브리드 컨버터)

  • Vu, Hai-Nam;Tran, Dai-Duong;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.52-53
    • /
    • 2015
  • This paper introduces a novel hybrid converter combining a full-bridge soft switching converter and a full-bridge LLC converter. In this topology all the primary switches can achieve ZVS and ZCS all over the operation range. An additional switch and a diode are added in the secondary side of full-bridge converter to eliminate the circulating current and to provide a separate freewheeling path. The hybrid structure makes it possible to deliver the power to the secondary all the time of operation, thereby improving the efficiency. The proposed topology is suitable for the applications such as on-board chargers for electric vehicles and high power dc-dc converters. A 6.6-kW prototype converter was implemented and 97.5% efficiency was obtained through the experiments.

  • PDF

Characteristics of New Small Scale Boost PWM Chopper Circuit (새로운 소용량 승압형 PWM 초퍼 회로의 특성)

  • Kim, Hyui-Chil;Park, Han-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.98-107
    • /
    • 2009
  • Actually, The hard switching high frequency PWM DC-DC converters are existing accompany, the high frequency of pulse modulation carrier frequency increase of switching loss of power semiconductor switching elements, there are have some problem points of EMI etc. This compliance with a voltage surge or the electric current surge are where the switching transient phenomenon accompanies. In order to solve like this problem effectively it described the principle of operation of New Small Scale Boost PWM Chopper circuits from the present paper, draw Characteristics from simulation and experiment.

Sensitivity Analysis of Power System Oscillation Modes Induced by Periodic Switching Operations of SVC by the RCF Method (RCF 기법을 이용한 SVC의 주기적 스위칭 동작에 의한 전력계통 진동모드 감도해석)

  • Kim, Deok-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.363-368
    • /
    • 2008
  • In this paper, the Resistive Companion Form(RCF) analysis method is applied to analyze small signal stability of power systems including thyristor controlled FACTS equipments such as SVC. The eigenvalue sensitivity analysis algorithm in discrete systems based on the RCF analysis method is presented and applied to the power system including SVC. As a result of simulation, the RCF analysis method is proved very effective to precisely calculate the variations of eigenvalues or newly generated unstable oscillation modes after periodic switching operations of SVC. Also the eigenvalue sensitivity analysis method based on the RCF analysis method enabled to precisely calculate eigenvalue sensitivity coefficients of controller parameters about the dominant oscillation mode after periodic switching operations in discrete systems. These simulation results are different from those of the conventional continuous system analysis method such as the state space equation and proved that the RCF analysis method is very effective to analyze the discrete power systems including periodically operated switching equipments such as SVC.

AC-DC buck converter topology of high power factor with soft switching mode (소프트 스위칭 모드에 의한 고역률의 AC-DC 강압형 컨버터 토폴로지)

  • 문상필;서기영;전중함;김영철;김준홍;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.417-422
    • /
    • 1997
  • This paper proposed that a AC-DC Converter topology of high power factor with soft switching mode operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging engergy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF