• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.03 seconds

Development of Optical Switch by using MEMS (MEMS를 이용한 Optical Switch의 개발)

  • Choi, Hyung
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.154-155
    • /
    • 2000
  • Optical switches using MEMS(Micro Electro Mechanical Systems) process have been widely developed since conventional optical switches cannot meet the requirements of new systems. $N_2$ type micro-mirror switches are easy to control, have simple optical systems but have difficulties in expanding the ports. Micromirrors of 2N type switches must be tilted at various angles and have relatively complicated optical systems but have advantage in expanding ports. Another type of optical switch using MEMS process is micro-waveguide type. It is reliable than other types since it has no moving parts.

  • PDF

A Report on Test Results of Pressure Operated Switch (압력스위치 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

Distribution Automation Switch Testing Software Development (배전자동화용 개폐기 시험용 소프트웨어 개발)

  • Ok, Ki-Jung;Kim, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.446-448
    • /
    • 2001
  • We have developed the testing software for KEPCO operators to maintain the small-scale distribution automation system effectively. The testing software is used to monitor the present status, to measure the analog value(voltage, amperage) and to control the switch and FRTU(Feeder Remote Terminal Unit) in order to find out a disabled part of the system. And at the stage of inspection of the switch and FRTU, it can screen the inferior one.

  • PDF

Implementation of a ZVT-PRT Current Controlled Inverters using a Digital Signal Processor (DSP를 이용한 ZVT-PRT 전류제어형 인버터의 구현)

  • 이성룡;전칠환;김상수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.425-429
    • /
    • 2002
  • In this paper, a single-phase inverter using a diode bridge-type resonant circuit to implement ZVT(Zero Voltage Transition) switching is presented. The current control algorithm is analyzed about how to design the circuit with auxiliary switch which can ZVT operation for the main power switch. The simulation and experimental results would be shown to verify the proposed current algorithm, because the main power switch is turn on with ZVT and the hi-directional inverter is operated.

  • PDF

PWM Control of Reduced Switch Z-Source Inverter (스위치 저감형 Z-Source Inverter PWM 제어)

  • Kim, Seong-Hwan;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.53-57
    • /
    • 2019
  • In this paper, we propose a new Z-source inverter structure to reduce switching elements and PWM pulse control method. Z-network is connected between the inverter backplane and ground, rather than between the DC voltage and the inverter in an improved Z-source inverter. And the improved Z-source inverter has the advantages of limiting the capacitor inrush current and reducing the capacitor voltage stress. We have proposed a topology of a new type of switch-reduced improved Z-source inverter that reduces the number of switches from six to four in an improved Z-source inverter and developed a PWM control method suitable for the proposed topology. The characteristics and the performance of the proposed method were verified by using PSIM simulation.

Study on performance improvement of electric-point machine monitoring system (전기선로전환기 모니터링시스템의 성능 향상에 관한 연구)

  • Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4509-4514
    • /
    • 2010
  • In this thesis, the effect of switch maintenance improvement is confirmed after testing and operating the switch monitoring system that were researched and developed originally in order to improve method of electric switch maintenance. However, as in an automatic interlocking station where a ground crew was not placed, repair and inspection could not be carried out until the maintenance person comes in case of switch problems or maintenance. In order to improve this issue, control module was installed in a monitoring system which can communicate through a data radio to a remote computer. Thus, the monitoring device can receive control information which a remote computer commands during the operation of switches. Afterward, it shows information on the real-time status of swith, in particular, anomaly situation through user interface after the switch is operated. By improving performance of the monitoring system in this way which can be managed and controled at a remote place, the prompt countermeasure system in case of disruption will be built and as a result, efficiency and convenience of maintenance improvement will be expected to increase.

CONTROL CHARACTERISTICS OF SINGLE-SWITCH, THREE-PHASE BUCK RECTIFIERS

  • Song, Joong-Ho;Kim, Yong-Duck;Lee, Dong-Yun;Choy, Ick;Choi, Joo-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.658-662
    • /
    • 1998
  • A pulse frequency modulation control method for single-switch three-phase buck rectifiers is comprehensively studied in this paper. The proposed pulse frequency control method leads the three-phase buck rectifier to high performance system that can draw the nearly sinusoidal imput-line currents. The simulated and experimental results demonstrate that the system provides low total harmonic distortion of the input-line currents, high-power factor, and good output voltage regulation.

  • PDF

A Study on the Design and Control Method for Unmanned Ground Vehicle System (무인 자율 주행 차량 시스템 설계 및 제어에 관한 연구)

  • Moon, Hee-Chang;Park, Myung-Wook;Kim, Jung-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.446-455
    • /
    • 2010
  • The research presented covers the design and control method of unmanned ground vehicle (UGV). An electric vehicle is used and is driven by DC motor. The power system on the UGV has been adjusted and actuators have been installed for steering and brake automation. A toggle switch is implemented to easily switch between manual and autonomous states. The UGV state is monitored by a velocity sensor, as well as steering and brake position sensors. An emergency stop device was designed and installed to quickly and safely stop the UGV. Different control methods, including the PID controller, were studied for improved steering responsiveness, and results were confirmed through experimentation. Satisfactory performance was achieved and several possible areas of future research have arisen.

Open Switch Fault Tolerance Control of Active NPC Inverters With HF/LF Modulation (HF/LF 변조를 적용한 Active NPC 인버터의 개방 고장 허용 제어)

  • Jung, Won Seok;Kim, Ye-Ji;Kim, Seok-Min;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.170-177
    • /
    • 2020
  • This paper presents an open-fault tolerance control method for active neutral point clamped (ANPC) inverter with high frequency/low frequency (HF/LF) modulation. By applying the ANPC inverter with SiC MOSFETs and Si IGBTs, the system efficiency and performance can be improved compared to a Si-based inverter. HF/LF modulation is used for a megawatt-scale inverter to minimize the commutation loop. The open-switch failure in megawatt-scale inverter causes severe damage to load and huge expenses when the inverter has been shut-down. The proposed tolerance control of open-switch failure provides continuous operation and improved reliability to the ANPC inverter. The effectiveness of the proposed fault tolerance control is verified by simulation results.

Performance improvement of ER switch congestion control algorithm for ABR service in ATM network (ATM망에서 ABR 서비스를 위한 ER 스위치 폭주 제어 알고리즘의 성능 개선)

  • 김운하;박성곤;조용환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.9
    • /
    • pp.1890-1906
    • /
    • 1997
  • A new ER feedback switch control algorithm, called EMRCA(Explicit Max-min Rate Control Algorithm), to control the ABR services traffic in the ATM networks, is proposed in this thesis. This scheme was interpreted the ACR variation residing on between a transient state and a stable state using the two thresholds that is the $TH_{high}$ and $TH_{low}$ in the queue to detect switch nodes congestion, and decreased the difference of minimum and maximum ACR all active connection to enhance the line bandwidth utilization. The proiposed scheme used a minimum and maximum rate of all active connections to select the connection whose the congestion rate inveoked, and uses a congestion detection mechanixm to prevent some potential cogestion by regulating selected contection.s The EMRCA scheme showed ACR variation more stable that the EPRCA scheme, also reduced buffer size of the switch, and achieved higher link utilization than the EPRCA scheme.

  • PDF