시뮬레이션을 통한 정류형 초전도 전류발생장치의 동작특성해석 (The Analysis of operational characteristic of superconducting current generator by computer simulation)

  • 추용;주민석;홍중배;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.95-97
    • /
    • 1995
  • A superconducting current generator, or a superconducting rectifier(SCR) is used as a current source to energize a superconducting magnets in SMES, MRI. We selected a full-wave SCR among various SCR models and analyzed its operational characteristics by computer simulation. In process of pumping the current, the improvement of performance is dependent on how much bigger the open resistance of the switch is in comparison to load coil impedance when one of two switches become active. Faster transfer can he seen in resistive commutation mode by shortening the time elapsed for the resistance to arrive at certain level from zero state. Although recovery time for the switch has no direct effect on current pumping, optimal switch design is needed to increasing operational frequency.

  • PDF

ATM망에서 ABR서비스를 위한 Relative Rate 스위치 알고리즘의 성능 해석 (Analysis of a relative rate switch algorithm for the ABR service in ATM networks)

  • 김동호;조유제
    • 한국통신학회논문지
    • /
    • 제23권5호
    • /
    • pp.1384-1396
    • /
    • 1998
  • 본 논문에서는 ATM망에서 ABR (Available Bit Rate) 흐름제어를 위한 RR (Relative Rate) 스위치 알고리즘의 성능을 해석하였다. RR 스위치는 망의 폭주상황을 BRM (Backward Resource Management) 셀의 CI(Congestion Indication) 비트와 NI(No Increase) 비트를 이용하여 송신원에 전달하는 방식이다. 이러한 RR 스위치는 폭주 판단 (congestion detection)과 폭주 통지(congestion notification) 방법에 따라 여러 방식 으로 구현될 수 있다. 본 논문에서는 폭주 판단과 통지 방법에 따른 세 가지 방식의 RR 스위치 알고리즘의 구현 방식을 제안하고, 평형 상태에서 송신원의 ACR (Allowed Cell Rate)과 스위치의 큐 길이의 변화를 유체흐름 근사법(fluid flow approxim­a ation)을 이용하여 해석하였다. 이를 이용하여 RR 스위치에 대한 평형상태에서의 큐 길이의 최대값과 최소값에 대한 상.하한치를 유도하고, ABR 파라미터들의 변화에 따른 큐 길이의 영향을 분석하였다. 또한, 버퍼 고갈에 의한 링크 이용 효율의 저하와 버퍼 범람에 의한 셀 손실을 동시에 방지할 수 있는 RIF(Rate Increase Factor)와 RDF(Rate Decrease Factor) 파라미터의 선택영역을 제시하였다.

  • PDF

2.4[GHz]/5.8[GHz] 이중대역 SPDT 스위치 설계 (Design of a Dual-Band Switch with 2.4[GHz]/5.8[GHz])

  • 노희정
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.52-58
    • /
    • 2008
  • 본 논문에서는 2.4[GHz]/5.8[GHz] 대역의 이중대역 스위치 설계에 대하여 논한다. 이 스위치는 TDD시스템에 적용 가능하며, 광대역 특성을 개선할 수 있는 새로운 구조를 제안하고 시뮬레이션을 통해 최적의 구조로 설계하였다. 2.4[GHz]/5.8[GHz] 이중대역 스위치는 현재 상용화되고 있는 802.11a/b/g 시스템에 응용할 수 있는 광대역, 고출력, 높은 격리도를 갖는 구조를 연구하였다. 스위치의 송신부는 2개의 FET를 스택 구조로 병렬 스위칭 소자로 동작하도록 설계하였다. 수신부는 기본적인 직/병렬 FET에 추가로 직렬 FET를 삽입한 비대칭 구조를 갖도록 수신부를 설계하였다. SPDT(Single Pole Double Throw) Tx/Rx FET 스위치는 하나의 입력에 2개의 출력으로 스위칭할 수 있는 장치이다. 이 제작된 스위치는 삽입손실 특성은 DC$\sim$6[GHz]까지 3[dB]보다 낮으며 수신경로의 격리도는 -30[dB]이하의 특성을 가지고 있다.

ATM망에서 ABR 서비스를 위한 혼잡회피 알고리즘의 성능 분석 및 평가 (A Performance Analysis and Evaluation of Congestion Avoidance Algorithm for ABR service over ATM Networks)

  • 하창승;조익성
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권3호
    • /
    • pp.80-91
    • /
    • 2002
  • ATM 네트워크의 목적은 다양한 네트워크의 접속을 지원하는 것이다. ATM 망에서 ABR 서비스는 CBR, VBR에 할당된 전송률을 제외한 나머지를 이용해서 데이터를 전송한다. 오디오 또는 비디오 데이터와 같이 실시간 전송이 필요한 서비스들은 전송지연이 제한되는 CBR이나 VBR 트래픽을 이용하여 제공할 수 있지만, 이런 경우에는 전체 전송률을 효과적으로 사용하지 못하는 단점이 있다. 따라서 본 논문에서는 ABR 스위치의 스위치 알고리즘인 ERICA(Explicit Rate Indicate Avoidance) 스위치 방식과 EPRCA(Enhanced Proportional Rate Control Algorithm) 스위치 방식의 성능을 평가하기 위하여 시뮬레이션을 수행하였다. 시뮬레이션의 평가 기준으로 과도상태와 정상상태에서 각 송신원에서의 전송률(ACR:Allowed Cell Rate)의 변화, 큐 길이, 링크 대역폭 이용률과 전송률의 공평성 여부를 사용하였다. 실험결과 EPRCA 스위치 방식은 ERICA 방식보다 뛰어난 반응 특성을 나타내는 결과를 얻을 수 있었으며, 안정성과 페어웨어 특성은 ERICA 스위치 방식이 EPRCA 스위치 방식보다 우수한 결과를 얻을 수 있었다.

  • PDF

대역 확산 전력선 통신을 위한 양방향 적응 결합기 설계 (Design of a Bidirectional Adaptive Coupler for Spread Spectrum Power Line Communications)

  • 유영규;우대호;최석우;김동용
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.623-628
    • /
    • 2007
  • This paper presents the new power line coupler which is applicable to spread spectrum power line communications. The proposed coupler maintains the adequate value of a capacitor between the transmitter mode and the receiver mode using a switch. In the transmit mode, the relatively high value of the capacitor is chosen to minimize the attenuation of transmitted signals. In the receiver mode, the value of the capacitor is chosen to be small enough so that the coupler attenuates power line noises. This coupler reduced the magnitude distortion due to having a high Q value and the power consumption caused by the AC current flowing into the capacitor. The simulation and measurement results show the improved performance in the transmitter and receiver mode, respectively.

모드 전환형 펄스충전기론 이용한 폐납축전지 재활용에 관한 연구 (An Study for reuse of the waste lead battery using Pulse Charger with mode conversion type)

  • 신춘식;안영주;김상동;신영미;김종달;김동완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.101-107
    • /
    • 2007
  • In this paper, the pulse charger with mode consersion type is proposed that can reuse the waste lead battery. The pulse charger uses the switch mode of the forward convert method. The pulse charger maintain the constant voltage in state removing the lead battery and when it connected the pulse charger, it is converted the charge mode of the constant current immediately. It continues the rapid charge until the full state of the lead battery. After that the pulse charger is converted to the charge mode of constant voltage automatically, and then it continues the normal charge. The experiment results show that the effectiveness of pulse charger such as the good performance and the prolonged durability in lead battery according to capacity states.

  • PDF

새로운 소프트 스위칭형 벅-부스터 컨버터의 효율개선 (Efficiency Improvement of New Soft Switching Type Buck-Boost Chopper)

  • 고강훈;곽동걸;서기영;권순걸;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.44-48
    • /
    • 1998
  • In the buck-boost DC-DC converter which is used at a certain situation such as in factories where loads often change a lot, the switches in the device make big energy loss in operating at Buck-Boost Mode due to hard switching and are affected by lots of stresses which decrease the efficiency rate of the converter. In order to improve this problem, to decrease the loss of snubber and switching, it has been investigated that zero voltage switching mode and zero current switching mode which make the operation of switches with soft switching. For the more sophisticated and advanced device, this paper is presented the Partial Resonant Soft Switching Mode Power Converter which is adapted the power converter having the partial resonant soft switching mode, that makes switches operate when the resonant current or voltage becomes zero by making the resonant circuit partially at turning on and off of the switches with suitable layout of the resonant elements and switch elements in the converter. Also, this paper includes the analysis and simulation of the Partial Resonant type Buck-Boost Chopper.

  • PDF

Fabrication of the mode (Reflective and Transmissive) switchable LCD

  • Jeong, Ho-Young;Kim, Dong-Sup;Jung, Gang-Seob;Moon, Jong-Won;Lee, Kyung-Ha;Lee, Deuk-Su;Yang, Myung-Su;Ahn, In-Ho;Kang, In-Byeong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.587-589
    • /
    • 2009
  • The mode (reflective and transmissive) switchable LCD has been developed by using a treated SR (Selective Reflector) polarizer. We believe that our approach will be a solution to overcome weak points for a reflective and transflective mode in a dark environment and a transmissive mode in a bright environment. Therefore, this can minimize power consumption, and also be easily fabricated in a current manufacturing process, ready for large sizes.

  • PDF

Bi-2223고온 초전도 코일의 영구전류 운전특성 실험 (The Experiment of the persistent current operation characteristics using Bi-2223 HTS coil)

  • 최세용;나완수;김정호;주진호;하홍수;오상수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.291-293
    • /
    • 2002
  • In this paper, we fabricated a persistent current mode magnet using Bi-2223 HTS tapes. The coil system consists of double pancake magnet and a persistent current switch and jointed them with solder. Persistent current mode operation of the system was measured experimentally by the decay behavior of the current. We found that resistive component of the system including flux flow resistance lead the exponentially field decay with time.

  • PDF

부분공진형 승.강압 초퍼의 새로운 토포로지 (New topology of Partial Resonant Type Buck-Boost Chopper)

  • 고강훈;라병훈;권순걸;구헌회;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.39-42
    • /
    • 1998
  • This paper is presented the Partial Resonant Soft Switching Mode Power Converter which is adapted the power converter having the partial resonant soft switching mode, that makes switches operated when the resonant current or voltage becomes zero by making the resonant circuit partially at turning on and off of the switches with suitable layout of the resonant elements and switch elements in the converter. Also, this paper includes the analysis and simulation of the Partial Resonant type Buck-Boost Chopper.