• Title/Summary/Keyword: Surgical success

Search Result 320, Processing Time 0.03 seconds

Retrospective studies of dental implant placement at each intraoral site and situation (임플란트 식립 유형에 따른 후향적 연구)

  • Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chae, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

Traumatic Hemothorax Caused by Thoracic Wall and Intrathoracic Injuries: Clinical Outcomes of Transcatheter Systemic Artery Embolization (흉벽 및 흉곽 내 장기 손상으로 인한 외상성 혈흉: 전신 동맥 색전술의 임상 결과)

  • Chang Mu Lee;Chang Ho Jeon;Rang Lee;Hoon Kwon;Chang Won Kim;Jin Hyeok Kim;Jae Hun Kim;Hohyun Kim;Seon Hee Kim;Chan Kyu Lee;Chan Yong Park;Miju Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.923-935
    • /
    • 2021
  • Purpose We aimed to assess the clinical efficacy of transcatheter arterial embolization (TAE) for treating hemothorax caused by chest trauma. Materials and Methods Between 2015 and 2019, 68 patients (56 male; mean age, 58.2 years) were transferred to our interventional unit for selective TAE to treat thoracic bleeding. We retrospectively investigated their demographics, angiographic findings, embolization techniques, technical and clinical success rates, and complications. Results Bleeding occurred mostly from the intercostal arteries (50%) and the internal mammary arteries (29.5%). Except one patient, TAE achieved technical success, defined as the immediate cessation of bleeding, in all the other patients. Four patients successfully underwent repeated TAE for delayed bleeding or increasing hematoma after the initial TAE. The clinical success rate, defined as no need for thoracotomy for hemostasis after TAE, was 92.6%. Five patients underwent post-embolization thoracotomy for hemostasis. No patient developed major TAE-related complications, such as cerebral infarction or quadriplegia. Conclusion TAE is a safe, effective and minimally invasive method for controlling thoracic wall and intrathoracic systemic arterial hemorrhage after thoracic trauma. TAE may be considered for patients with hemothorax without other concomitant injuries which require emergency surgery, or those who undergoing emergency TAE for abdominal or pelvic hemostasis.

The Surgical Treatment of Malignant Bowel Obstruction Caused by Recurrent Gastric Cancer (재발된 위암 환자에서 발생한 악성 장폐쇄증의 수술적 치료)

  • Yoo, Byung-Eun;Park, Joong-Min;Jang, You-Jin;Kim, Jong-Han;Park, Sung-Soo;Park, Seong-Heum;Kim, Seong-Ju;Mok, Young-Jae;Kim, Chong-Suk
    • Journal of Gastric Cancer
    • /
    • v.8 no.3
    • /
    • pp.148-153
    • /
    • 2008
  • Purpose: Malignant bowel obstruction caused by recurrent gastric cancer must be treated appropriately to improve the effects of treatment and to prolong survival. We reviewed the surgical treatments for malignant bowel obstruction caused by recurrent gastric cancer. Materials and Methods: The subjects were patients with malignant bowel obstruction caused by recurrent gastric cancer and these patients were treated by surgical procedures at our hospital from 1998 to 2008. The patients were treated by resection, ostomy or bypass. The success of treatment was decided when the patients were able to tolerate more than a liquid diet. Results: 42 patients were treated 46 times by surgical procedures. Resection was done12 times, ostomy was done 24 times and bypass was done 10 times. The hospital stay and the period to liquid diet after the operation were shorter in the ostomy group. The post operative morbidity rate was 21.7% and the post operative death rate was 8.7%. There was no significant difference in survival according to the type of surgery. Conclusion: Ostomy is good choice for selected patients because it has a shorter hospital stay and period to liquid diet. There was no significant difference in survival according to the type of surgery because curative resection is difficult to perform in patients with malignant bowel obstruction.

  • PDF

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

Position Control of Shape Memory Alloy Actuators Using Self Tuning Fuzzy PID Controller

  • Ahn Kyoung-Kwan;Nguyen Bao Kha
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.6
    • /
    • pp.756-762
    • /
    • 2006
  • Shape Memory Alloy(SMA) actuators, which have the ability to return to a predetermined shape when heated, have many potential applications such as aeronautics, surgical tools, robotics and so on. Although the conventional PID controller can be used with slow response systems, there has been limited success in precise motion control of SMA actuators, since the systems are disturbed by unknown factors beside their inherent nonlinear hysteresis and changes in the surrounding environment of the systems. This paper presents a new development of a SMA position control system by using a self-tuning fuzzy PID controller. This control algorithm is used by tuning the parameters of the PID controller thereby integrating fuzzy inference and producing a fuzzy adaptive PID controller, which can then be used to improve the control performance of nonlinear systems. The experimental results of position control of SMA actuators using conventional and self-tuning fuzzy PID controllers are both included in this paper.

Current Concepts in Arthroscopic Treatment of Anterior Shoulder Instability (견관절 전방 불안정에 대한 관절경적 최신 치료 경향)

  • Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.13-27
    • /
    • 2003
  • In the past, the report of shoulder instability undergoing open shoulder stabilization had satisfactory outcomes of greater than 90%. However, the functional loss of open procedure is severe in abduction and external rotation especially. Current arthroscopic techniques for shoulder instability result in success rate equal to open surgical procedure when the labrum is properly fixed to the glenoid rim using suture anchors, the capsule is tightened, and associated bony and soft tissue pathology is addressed. The arthroscopic surgery facilitates the view within shoulder joint for more accurate diagnosis, reduces operating time, minimises postoperative pain, reduces operative morbidity, improves shoulder function, and provides the possibility to perform other procedure simultaneously. However, to accomplish a successful arthroscopic stabilization procedure and to prevent complications, numerous advanced arthroscopic skill must be mastered. Although the arthroscope provides means to visualize new lesions, the pathomechanism and biomechanical explanation is not clear yet. Further studies are necessary to develop for shoulder reconstruction.

  • PDF

Updates on the Inferior Alveolar Nerve Block Anesthesia (하치조신경전달마취의 최신지견)

  • Paeng, Jun-Young
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.3-10
    • /
    • 2014
  • The inferior alveolar nerve (IAN) block is the most frequently used mandibular injection technique for achieving local anesthesia for restorative and surgical procedures. However, The IAN block does not always result in successful anesthesia, especially pulpal anesthesia. Lidocaine is used as a "standard" local anesthetic for the inferior alveolar nerve. Articaine recently joined Korean market as a form of dental cartridge. It has an advantage of superior diffusion through bony tissue. A variety of trial was performed to improve the success rate of inferior alveolar nerve block. In this review, the recent update related with inferior alveolar nerve block anesthesia will be discussed on the anatomical consideration, anesthetic agent, technique, and complications.

Lesser Metatarsal Osteotomies for Metatarsalgia (중족골통에서의 소족지 중족 절골술)

  • Lee, Seung-Yeol;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.3
    • /
    • pp.83-87
    • /
    • 2017
  • Metatarsalgia means the pain under the lesser metatarsal heads. The many causes of metatarsalgia can be categorized into three groups: local disease in the region, altered forefoot biomechanics, and systemic disease affecting the region. Surgical options need to be considered if nonsurgical treatment fails. The metatarsal osteotomies are designed primarily to reduce the weightbearing forces on the metatarsal head by elevating or shortening the metatarsal. Many lesser metatarsal osteotomies have been described, and their success depends on many factors. Regardless of the method employed, it is important to maintain or restore the metatarsal cascade to maintain an even pressure under the lesser metatarsal heads and prevent transfer lesions. The surgeon must understand the effects of the metatarsal osteotomy on the forefoot patho-biomechanics and decide, using a combination of clinical examinations and imaging, whether the desired effect of the osteotomy is to shorten or elevate the metatarsal head or both.

Design of Dexterous Manipulator for MIS (복강경 수술을 위한 지능형 작동기의 제작)

  • Song, Ho-Seok;Chung, Jong-Ha;Lee, Jung-Ju
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.823-828
    • /
    • 2004
  • Minimally Invasive Surgery (MIS) is surgery of the chest, abdomen, spine and pelvis, done with the aid of a viewing scope, and specially designed instruments. Benefits of minimally invasive surgery are less pain, less need for post-surgical pain medication, less scarring and less likelihood for incisional complications. Since the late 1980's, minimally invasive surgery has gained widespread acceptance because of the such advantages. However there are significant disadvantages which have, to date, limited the applications for these promising techniques. The reasons are limited degree-of-freedom, reduced dexterity and the lack of tactile feeling. To overcome such disadvantages many researchers have endeavored to develop robotic systems. Even though some robot aided systems achieved success and commercialized, there still remain many thing to be improved. In this paper, the robotic system which can mimic whole motions of a human arm by adding additional DOF is presented. The suggested design is expected to provide surgeons with improved dexterity during minimally invasive surgery.

  • PDF

Isometry of the Posterior Cruciate Ligament (후방 십자 인대의 등장성)

  • Lee, Byung Ill
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.15-20
    • /
    • 1998
  • Less has been written about the PCL than the ACL. There has, however, been an increasing amount of the interest in the PCL recently. Surgical reconstructions using grafts are often performed. However, these procesures often fail to provide long-term stability and function. Graft attachment sites are critical determinants of success in the PCL reconstruction. The clinical literature contains conflicting recommendations for graft attachment sites. We present a review of the isometry of the PCL.

  • PDF