• 제목/요약/키워드: Surgical simulation

검색결과 154건 처리시간 0.018초

2단 절개 형태를 가지는 악교정 수술 장치 연구 (A Study of Orthognathic Surgical Guides with Two-stage Split Path)

  • 김민욱;박충환;노지형;정의성;박영상;김동국;서요한;우영재;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

The Effect of Preoperative Three Dimensional Modeling and Simulation on Outcome of Intracranial Aneursym Surgery

  • Erkin Ozgiray;Bugra Husemoglu;Celal Cinar;Elif Bolat;Nevhis Akinturk;Huseyin Biceroglu;Ceren Kizmazoglu
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권2호
    • /
    • pp.166-176
    • /
    • 2024
  • Objective : Three-dimensional (3D) printing in vascular surgery is trending and is useful for the visualisation of intracranial aneurysms for both surgeons and trainees. The 3D models give the surgeon time to practice before hand and plan the surgery accordingly. The aim of this study was to examine the effect of preoperative planning with 3D printing models of aneurysms in terms of surgical time and patient outcomes. Methods : Forty patients were prospectively enrolled in this study and divided into two groups : groups I and II. In group I, only the angiograms were studied before surgery. Solid 3D modelling was performed only for group II before the operation and was studied accordingly. All surgeries were performed by the same senior vascular neurosurgeon. Demographic data, surgical data, both preoperative and postoperative modified Rankin scale (mRS) scores, and Glasgow outcome scores (GOS) were evaluated. Results : The average time of surgery was shorter in group II, and the difference was statistically significant between the two groups (p<0.001). However, no major differences were found for the GOS, hospitalisation time, or mRS. Conclusion : This study is the first prospective study of the utility of 3D aneurysm models. We show that 3D models are useful in surgery preparation. In the near future, these models will be used widely to educate trainees and pre-plan surgical options for senior surgeons.

Research Priorities in Light of Current Trends in Microsurgical Training: Revalidation, Simulation, Cross-Training, and Standardisation

  • Nicholas, Rebecca Spenser;Madada-Nyakauru, Rudo N.;Irri, Renu Anita;Myers, Simon Richard;Ghanem, Ali Mahmoud
    • Archives of Plastic Surgery
    • /
    • 제41권3호
    • /
    • pp.218-224
    • /
    • 2014
  • Plastic surgery training worldwide has seen a thorough restructuring over the past decade, with the introduction of formal training curricula and work-based assessment tools. Part of this process has been the introduction of revalidation and a greater use of simulation in training delivery. Simulation is an increasingly important tool for educators because it provides a way to reduce risks to both trainees and patients, whilst facilitating improved technical proficiency. Current microsurgery training interventions are often predicated on theories of skill acquisition and development that follow a 'practice makes perfect' model. Given the changing landscape of surgical training and advances in educational theories related to skill development, research is needed to assess the potential benefits of alternative models, particularly cross-training, a model now widely used in non-medical areas with significant benefits. Furthermore, with the proliferation of microsurgery training interventions and therefore diversity in length, cost, content and models used, appropriate standardisation will be an important factor to ensure that courses deliver consistent and effective training that achieves appropriate levels of competency. Key research requirements should be gathered and used in directing further research in these areas to achieve on-going improvement of microsurgery training.

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Heterotopic Ossification

  • Hong, Seok-Hwan;Lee, Yong-Bin;Jung, Young-Soo;Jung, Hwi-Dong
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.84-86
    • /
    • 2016
  • Heterotopic ossification (HO) is the formation of mature bone in soft tissue where bone normally does not exist. Although HO is among the most common complications after orthopedic surgery, it is not familiar to oral and maxillofacial surgeons. Here we report rare cases of HO. When a patient presents atypical osseous lesions, HO as well as similar lesions such as osteoma, osteochondroma should be considered in the provisional diagnosis. Three-dimensional reconstruction of preoperative computerized tomography imaging improves surgical success.

Bio-ink Materials for 3D Bio-printing

  • Kim, Ji Seon;Hong, Soyoung;Hwang, Changmo
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.49-59
    • /
    • 2016
  • 3D printing is also known as additive manufacturing technique in which has been used in various commercial fields such as engineering, art, education, and medicine. The applications such as fabrication of tissues and organs, implants, drug delivery, creation surgical models using 3D printer in medical field are expanding. Recently, 3D printing has been developing for produce biomimetic 3D structure using biomaterials containing living cells and that is commonly called "3D bio-printing". The 3D bio-printing technologies are usually classified four upon printing methods: Laser-assisted printing, Inkjet, extrusion, and stereolithograpy. In the bio-printing, bio-inks (combined hydrogels and living cells) are as important components as bio-printing technologies. The presence of various types of bioinks, however, in this review, we focused on the bio-inks which enables bioprinting efficacy using hydrogels with living cells.

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.

Development of a Five-Day Basic Microsurgery Simulation Training Course: A Cost Analysis

  • Singh, Masha;Ziolkowski, Natalia;Ramachandran, Savitha;Myers, Simon R.;Ghanem, Ali Mahmoud
    • Archives of Plastic Surgery
    • /
    • 제41권3호
    • /
    • pp.213-217
    • /
    • 2014
  • The widespread use of microsurgery in numerous surgical fields has increased the need for basic microsurgical training outside of the operating room. The traditional start of microsurgical training has been in undertaking a 5-day basic microsurgery course. In an era characterised by financial constraints in academic and healthcare institutions as well as increasing emphasis on patient safety, there has been a shift in microsurgery training to simulation environments. This paper reviews the stepwise framework of microsurgical skill acquisition providing a cost analysis of basic microsurgery courses in order to aid planning and dissemination of microsurgical training worldwide.

의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석 (Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes)

  • 이민아;류민영;신동진;김태균
    • 소성∙가공
    • /
    • 제24권2호
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.

SBS에 기반한 이진 볼륨 데이타의 렌더링 알고리즘 (A Rendering Algorithm for Binary Volume Data based on Slice-based Binary Shell)

  • 김보형;서진욱;신병석;신영길;강흥식
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제27권5호
    • /
    • pp.441-449
    • /
    • 2000
  • 이진 볼륨 데이타(binary volume data)는 외과 수술 시뮬레이션(surgical simulation)이나 컬러 볼륨 렌더링과 같이 그레이-스케일 볼륨(gray-scale volume)을 이용하기에는 부적절한 분야에서 유용 하게 사용된다. 본 논문에서는 이진 볼륨을 효과적으로 표현하기 위해서 새로운 자료구조인 슬라이스 기반 이진 쉘(SBS : Slice-based Binary Shell)을 제안하고, 이 자료구조를 이용한 렌더링 알고리즘도 함께 제시한다. 슬라이스 기반 이진 쉘은 렌더링을 위해 필요한 최소한의 표면 복셀(surface voxel)들을 슬라이스 순으로 저장하고 복셀 좌표의 직접 계산을 가능하게 하기 때문에, 다중 개체(multiple objects)를 포함하고 있는 볼륨을 렌더링할 때 매우 효율적이다. 본 논문에서 제시하고 있는 슬라이스 기반 이진 쉘의 렌더링 알고리즘은 특별한 렌더링 가속 하드웨어가 없는 PC에서 100개 이상의 이진 개체들을 1초 내에 렌더링할 수 있다.

  • PDF