• Title/Summary/Keyword: Surface hardness change

Search Result 262, Processing Time 0.028 seconds

광경화형 글래스아이오노머 시멘트의 두께 및 시간경과에 따른 경도의 변화 (HARDNESS CHANGE OF LIGHT-ACTIVATED GLASS IONMER CEMENT WITH THICKNESS AND TIME)

  • 이경진;오원만;김선헌
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.303-315
    • /
    • 1995
  • An adequate and homogeneous cure of light-activated restroative material is very important for improvement of marginal adaptation and prevention of marginal leakage, secondary caries and pulpal irritation as well as expressing natural physical property of that material. The purpose of this study was to evaluate the change of surface hardness and cure uniformity of light-activated glass ionomer cements. Restorative(Fuji II LC, Vitremer) and lining(Baseline VLC, Vitrebond) light-activated glass ionomer cements were investigated for this study. The surface hardness of the top and bottom surfaces and cure uniformity of each 1mm, 1.5mm, 2mm, 2.5mm & 3mm in the thickness of specimen were measured immediately, at 1 hour, 24 hours and 1 week after light activation. The surface hardness change and cure uniformity of all the specimens were measured by Knoop hardness tester. The results were as follows. 1. The surface hardness of top and bottom surfaces in all groups increased with time(p<0.01). 2. Both top and bottom surfaces hardness of Vitrebond group measured immediately after light-activation were significantly lower than those of the other groups(p<0.01). 3. The surface hardness of top and bottom surfaces of restorative light -activated glass ionomer cements was higher than those of lining materials at 1 week(p<0.10). 4. Surface hardness of Vitremer group decreased as the specimen thickness increased, except top and bottom surfaces hardness of the specimen at 1 week(p<0.01). There was no significant difference in the surface hardness of Fuji II LC with changes in the thickness except bottom surface hardness of specimen at 24 hours and 1 week (p>0.05). 5. Surface hardness of Vitrebond group significantly decreased as the specimen thickness increased(p<0.01). There was no significant difference in the surface hardness of Baseline VLC group with changes in the thickness except bottom surface hardness of specimen measured immediately after light -activation(p>0.05). 6. The hardness ratio of top against bottom surface in all groups decreased with time(p<0.05). 7. There was no significant difference in the hardness ratio of top against bottom surface with changes of the thickness except Vitrebond group, 24 hours and 1 week of Vitremer group and 1 week of Baseline VLC group (p>0.05). These results suggest that surface hardness of restorative ligh-activated glass ionomer cements were highter than those of lining light-activated materials. In all groups, the surface hardness and cure uniformity continuously increased with time.

  • PDF

발효음식이 의치상레진의 색상 및 표면경도 변화에 미치는 영향 (THE EFFECT OF FERMENTED FOODS ON THE COLOR AND HARDNESS CHANGE OF DENTURE BASE ACRYLIC RESINS)

  • 전열매;임헌송;신수연
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.344-355
    • /
    • 2004
  • Statement of problem: For a long time, many of denture base acrylic resins have been used for edentulous and partial edentulous patients because of easy manipulation and good mechanical properties, but its esthetic aspect has not been commented enough. Denture base acrylic resins also has caused esthetic problems due to discoloration or staining as in esthetic restoration. Many researches and reports have treated the problems and accomplished esthetic improvement. But these researches and reports dealt with general food colors or beverages, not with fermented foods. Purpose: This study is designed to assess what fermented foods, such as soy sauce, gochujang, and toenjang that many of Koreans have taken in, influence on the color and hardness variation of denture base acrylic resins. Materials and methods: For the procedure, twelve disks per 4 denture base acrylic resins were fabricated with a thickness of 2mm and 16mm in diameter. Each seven specimen were measured for discoloration with spectrophotometer, while the others, five specimen, for surface hardness change with Barcol hardness tester, over time. Each 12 specimen were immersed into the 4 beakers of fermented foods(soy sauces, gochujangs, toenjangs, deionized water), and $L^{*},a^{*}$, and $b^*$ values were measured for the color difference$({\Delta}E^*)$, on the 1st, 7th, and 28th day with spectrophotometer, with the measurement of surface hardness change. Each data observed was processed statistically. Results: The findings are as follows; Discoloration 1. All of denture base resins was not influenced by the kind of fermented foods, except for $QC20^{(R)}$ 2. Soy sauce and red pepper paste caused more change for denture base resins than deionized water and soy bean paste, except for Perform$^{(R)}$ 3. Most significant change was shown in Lucitone 199$^{(R)}$, whereas Perform$^{(R)}$ results in the least change for all immersed solution, with no statistical significance. Hardness change 1. Barcol hardness values in deposited specimens have been changed low degree, but with significant statistical change according to the kind of food and duration. 2. Lucitone$^{(R)}$ 199 as significantly lower Barcol hardness value than others do. Conclusion: Based on the above results, it suggests that the habitual intake of fermented foods is not helpful for the color stability of denture base acrylic resins because Soy sauce and red pepper paste mainly caused discoloration and surface hardness change. Particularly $Lucitone199^{(R)}$ shows specific discoloration and low surface hardness values. Therefore, it is recommended giving caution patients with denture of $Lucitone199^{(R)}$ especially against the habitual intake of fermented foods like soy sauce and red pepper paste.

염화물욕에서 아연도금층의 표면외관과 경도에 미치는 욕조성의 영향 (Effect of the bath composition on the surface appearance and the hardness of zinc deposits from the chloride bath)

  • 김영근;김명수
    • 한국표면공학회지
    • /
    • 제33권5호
    • /
    • pp.339-348
    • /
    • 2000
  • The study was conducted on the effect of bath composition on the surface appearance, the hardness and the crystal orientation of zinc electrodeposits from the chloride bath. (1) The hardness of the zinc electrodeposits from the chloride bath was increased by suppressing mass transfer of zinc through adding the organic additives and the chlorine ion in the electrolyte. (2) The surface whiteness of zinc deposits was decreased due to the change of the preferred orientation from (002) , (103) to (101) , (100) through increasing the organic additives and chlorine ion in the electrolyte. (3) The addition of Cu, Sn, Ni or Co in the chloride bath elevated the hardness of the zinc deposits but darkened the surface whiteness. (4) The optimum condition of the organic additives and the chlorine ion for increasing the hardness of zinc deposits and preventing dark surface ranges 0.3 m1/1 to 0.4 m1/1 and 6.5 mol/1 to 6.8mol/l respectively.

  • PDF

유한요소해석에 의한 코팅면의 브리넬 경도 평가: 제1보 - 타당성 연구 (Evaluation of Brinell Hardness of Coated Surface Using Finite Element Analysis: Part 1 - A Feasibility Study)

  • 박태조;강정국
    • Tribology and Lubricants
    • /
    • 제36권6호
    • /
    • pp.378-384
    • /
    • 2020
  • The friction surfaces of mechanical parts are heat-treated or coated with hard materials to minimize wear. Increasing the hardness is a very useful way to reduce abrasive wear. The general Brinell hardness test, which is widely used for metallic materials, is not suitable because it hardly shows any change in hardness when coated with thin films. In this study, we propose a basis for the application of the new Brinell hardness test method to the coated friction surface. An indentation analysis of the rigid sphere and elastic-perfectly plastic materials is performed using a commercial finite element analysis software. The results indicate that their loadto-diameter ratio is the same; the Brinell hardness test method can be applied even when the indenter diameter is on the micrometer scale. In the case of hard coating, it is difficult to calculate Brinell hardness using the diameter of the indentation, but the study revealed, for the first time, that it can be calculated using the depth of the indentation regardless of coating. The change in hardness owing to thin film coating over a wide load range implies that the hardness evaluation method is appropriate. Additional studies on various properties related to the substrate and coating material are required to apply the proposed method.

전해조건에 따른 니켈전착층의 경도와 항복 강도의 변화 (The change of the hardness and yield strength in the nickel electrodeposits depending upon the electrolysis condition)

  • 예길촌;김광수
    • 한국표면공학회지
    • /
    • 제16권1호
    • /
    • pp.3-9
    • /
    • 1983
  • The change of the hardness and yield strength depending upon the electrolysis conditions was investigated for Watts and bright nickel electrodeposits. The hardness of Watts nickel electrodeposits decreased with increasing current density in the range of 1-15A/Am2, while it increased with increasing bath temperature. The hardness of bright nickel deposits increased noticebly in comparison with that of Watts nickel electro-deposits. The hardness and the yield strength of the bright nickel electrodeposits increased considerably with decreasing current density and the highest value was obtained at the lowest current density (1A/dm2), while they decreased noticebly at the bath temperature of 80$^{\circ}C$ in comparison with that of 40-60$^{\circ}C$. The change of the hardness and the yield strength of bright nickel electrodeposits depending upon the electrolysis conditions could be mainly attributed to the variation of organic additives codeposited in the electrodeposits. The recrystallizatioin temperature(50% softening temperature) of the Wattss and the bright nickel electro-deposits was 520-280$^{\circ}C$ and 350-410$^{\circ}C$ respectively and then the recystallization temperature of bright nickel deposits was lower than that of the Watts nickel electrodeposits.

  • PDF

고주파열처리에 의한 SM45C 경도가 가공 표면 품위에 미치는 영향에 관한 연구 (A Study on the Surface Roughness Influenced by SM45C Hardness in High Frequency Induction Hardening)

  • 김원일;허성중
    • 열처리공학회지
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 1993
  • In this paper, the surface roughness influenced by Sm45C hardness in high frequency induction hardening and mechanical characteristics for the changed Hv 598 part and the unchanged hardness Hv 223 part by use of cermet and ceramic cutting tools was experimentally examined. Finally, we could be had some important results by processing surface roughness on cutting conditions such as cutting speed, feed rate, depth of cut and changes of tool nose radius. The results are summarized as follows. 1. In case of the same cutting condition, the hardness of workpiece was high and acquired the best processing surface roughness when the radius of the tool nose had 0.8 mm and feed rate was 0.04 mm/rev. 2. In case of the hardness of workpiece, though the cutting speed didn't have an effect on processing surface roughness, the less feed rate and the more processing surface roughness improved. On the other hand, the low inside the hardness of workpiece, the more cutting speed and the more feed rate increase, the processing surface of roughness improved. 3. Regardless of the hardness of workpiece, the change of the cutting depth didn't have great effect on the surface roughness. 4. On cutting the high surface hardness part with cutting tools of cermet and ceramic, it can be acquired the higher processing surface roughness because it hadn't been taken effect on cutting speed, In case of the cutting process of the low inside hardness part the two cutting tools have acquired the similar processing surface roughness.

  • PDF

도재소부용 금합금에서 인듐, 주석 첨가가 금속-도재계면 특성에 미치는 영향 (Effects of Indium and Tin on Interfacial Property of Porcelain Fused to Low Gold Alloys)

  • 남상용;곽동주;정석민
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.31-43
    • /
    • 2001
  • This study was performed to observe the micro-structure change of surface, behavior of oxide change of element, the component transformation of the alloy and the bonding strength between the porcelain interface in order to investigate effects of indium, tin on interfacial properties of porcelain fused to low gold alloy. Hardness of castings was measured with a micro-Vicker's hardness tester. The compositional change of the surface of heat-treated specimen was analyzed with an EDS and an EPMA. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The results were as follows: 1) The hardness value of alloy increased as increasing amount of indium addition. 2) The formation of oxidation increased as increasing indium and tin contents after heat treatment. 3) Diffusion of indium and tin elements increased as increasing indium and tin contents in metal-porcelain surface after porcelain fused to metal firing. 4) The most interfacial shear bonding strength was increased as increasing a composition of adding elements, and a heat-treatment time, and an oxygen partial pressure. From the results of this study it was found that the addition of alloying elements such as indium and tin increase hardness of as-cast alloy, produce surface oxide layer of adding elements by heat-treatment which may improve interfacial bonding strength between alloy and porcelain.

  • PDF

평면 Rolling에 의한 표면특성 변화에 관한 연구(l) (A Study on the Change of Suface Characteristics by plane suface Rolling(l))

  • 김희남
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1-5
    • /
    • 1997
  • The plane surface rolling, one of the plastic working process, good surface condition due to increase of surface roughness and hardness. It is well known that mechanism of surface rolling depends upon rolling conditions such as rolling speed, contact pressure, step length of rolling, the shape of roller and mechanical properties of material. In this study, the optimal value of the above parameter on the surface roughness were investigated by using the rolling tool with NACHI 6000ZZ ball bearing outer races on machine structure carbon steel[SM45C]

  • PDF

도재소부용 금합금의 열처리에 따른 기계적 성질 및 미세조직 변화에 관한 연구 (A Study on Changes of Mechanical Properties and Microstructure in Porcelain Fused to Gold Alloys by Heat Treatment)

  • 남상용;곽동주;차성수
    • 대한치과기공학회지
    • /
    • 제31권4호
    • /
    • pp.9-15
    • /
    • 2009
  • The purpose of this study was to observe the change of mechanical property and microstructure in porcelain fused to gold alloy by heat treatment. PFG alloys are composed with Au-Pd-Ag alloy of the additional elements with indium, tin and copper. Specimens were tested in hardness using vicker,s micro-hardness tester and the surface micro structural changes were analysed by SEM and EDS. The results were as fellows: 1. The vickers hardness showed highest in Au-Pd-Ag alloy of the additional element with tin. 2. By hardening-oxiding result, the vicker,s hardness increased in additional element with tin but there was no significant difference in additional elements with indium and copper. 3. The surface oxide layer of Au-Pd-Ag alloy with added indium and tin increased but there was small change in additional element with copper. 4. The elements of indium and tin increased with increasing heat treatment in the surface alloy.

  • PDF

전기자극의 시술에 따른 일회용 호침의 안전성 및 안정성 연구 (Assessment of Acupuncture Needle Safety and Stability on Applying Electroacupuncture)

  • 박경무;송윤경;임형호
    • 한방재활의학과학회지
    • /
    • 제19권1호
    • /
    • pp.187-199
    • /
    • 2009
  • Objectives : The electroacupuncture was generally has been used in oriental medicine doctors. In recent years, there have been a few studies about safety and stability of acupuncture needle in itself, but then again research of acupuncture needle safety and stability on applying electroacupuncture have been insignificant. Therefore we investigated the safety and change in mechanical characteristic of acupuncture needle in electroacupuncture therapy. Methods : We observed mechanical characteristic change by SEM(Scanning Electron Microscope) and EDX(Energy Dispersive X-ray Spectroscopy), evaluated the hardness by vickers hardness tester. We used MTT assay and cell stain to study about biocompatibility of electroacupuncture. Results : In this study, any corrosion of material, alternation of elements, and change of hardness were not observed in surface analysis using SEM and EDX. In cytotoxity evaluation using MTT assay and cell stain, cell survival rate was low when practicing the electroacupuncture for more than 3 hours. Conclusions : Change of mechanical property was not observed based on the test results using surface analysis and hardness estimation by the electroacupuncture. And considering the biocompatibility, electroacupuncture was thought to be safe in an hour based on cytotoxity evaluation using MTT assay and cell stain.