• 제목/요약/키워드: Surface gloss

검색결과 137건 처리시간 0.025초

Evaluation of Gloss Variation with a Novel Method

  • Sung, Yong-Joo;D. Steven Keller
    • 펄프종이기술
    • /
    • 제34권2호
    • /
    • pp.73-83
    • /
    • 2002
  • Gloss is very important optical property influencing the perceived quality of the paper surface as well as the surface after printing. Although the average gloss level of paper products or printed images is important to meet end use specifications, the occurrence of gloss mottle, or non-uniformity of gloss, is often of greater concern for meeting quality requirements, especially for the high gloss paper. Gloss variation originates from the irregularities of paper surface, especially surface roughness of paper. Roughness of paper can be divided into micro-roughness (under $1\mu m$ scale in variation) and macro-roughness (over $1\mu m$ scale in variation) depending on the scale of the irregularities. A clearer understanding of the gloss variation of paper can be achieved by separating the contributions of these two scales of roughness, and characterizing them independently. In order to do this, a novel gloss measuring method was introduced. This can detect local gloss with very high resolution. The effect of macro-roughness on gloss variation, which was identified by the measurable surface topography, was separated from the total gloss variation by using this method. The effect of micro-roughness was then estimated indirectly. The local gloss variations of various paper samples were then evaluated to demonstrate the utility of this approach.

복합레진의 표면 광택에 대한 평가 (Evaluation of surface gloss of composite resins)

  • 변지은
    • 대한치과의료관리학회지
    • /
    • 제11권1호
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

HIPS 성형품에서 성형조건이 표면 광택에 미치는 영향 (The Effect of Molding Conditions on the Surface Gloss of HIPS Molding)

  • 정영득;이미혜
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.81-85
    • /
    • 2000
  • The surface gloss of the injection molded part is one of the most significant point for evaluation the quality of products appearance. The effects of molding condition on the gloss of HIPS(High Impact Poly Styrene) molded part were investigated in this work. The measurements of gloss on the surface of molded part were carried out with different melt temperature, mold temperature, injection pressure and holding pressure. We observed the result of HIPS gloss compared with our's previous ABS study. The more melt and mold temperature increased, the brighter the gloss increase. Holding and injection pressure had little effect on the gloss. The gloss was effected in order of melt temperature, mold temperature, injection pressure, holding pressure.

  • PDF

ABS(Acrylonitrile-Butadiene-Styrene) 성형품의 성형조건이 표면 광택에 미치는 영향 (The Effects of Molding Conditions on the Surface Gloss of ABS Molding)

  • 정영득;황시현;이미혜
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.110-115
    • /
    • 1999
  • The surface gloss of an injection molded part is one of the most significant point for evaluating the quality of products appearance. The effects of process condition on the gloss of ABS(Acrylonitrile-Butadiene-Styrene) molded part were investigated in this work. The measurements of gloss and morphology on the surface of molded part were carried out with different melt temperature, mold temperature, mold surface roughness, injection pressure and holding pressure. Gloss had a maximum value with melt temperature in the range of 210 to 220 ${^\circ}C$ and with mold temperature 40 to 50${^\circ}C$ and with injection pressure 80~90 MPa, respectively. Melt temperature was shown to have the largest effect on gloss in our work. Gloss was not improved in the region of melt temperature 240${^\circ}C$ above and of mold temperature 60${^\circ}C$ above. It was concluded that the variation of gloss was mainly caused by rubber particles migration under shear stress not by their aggregation or necklace.

  • PDF

노출콘크리트 표면처리를 위한 거푸집 코팅재료 연구 (The mold form coating material research for the exposure concrete surface control)

  • 이영도
    • 한국건축시공학회지
    • /
    • 제10권5호
    • /
    • pp.137-143
    • /
    • 2010
  • 본 연구는 거푸집에 부착하는 코팅재료에 따른 콘크리트 표면광택도 비교 분석으로서 시멘트모르터로 제작한 시험체의 광택도를 분석하고 유동화제를 혼합한 콘크리트와 혼합하지 않은 콘크리트의 노출콘크리트 표면 광택의 특성을 분석한 것이다. 시멘트모르터를 이용한 코팅재료별 광택도 분석에서 광택도가 가장 높게 나타난 코팅재료는 7번 재료로 액체포장재의 일부이며 2번째는 3번 재료로 투명필름을 이용한 재료이다. 코팅필름의 소재에 따라 광택도가 다르게 나타난 것으로 미루어 소재의 표면입자 상태와 화학적 구성요소의 따라 다른 것으로 판단된다. 콘크리트의 표면상태를 매끄럽게 하기 위해서는 불투수성이며 매우 밀실한 표면을 가진 코팅재료를 사용하는 것이 효과적이다.

불규칙 패턴 에칭에 의한 표면 형상 제어와 광학적 특성 (Optical Property and Surface Morphology Control by Randomly Patterned Etching)

  • 김성수;이정우;전법주
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.800-805
    • /
    • 2017
  • Randomly patterned and wet chemical etching processes were used to treat anti-glare of display cover glasses. The surface and optical properties of grain size and surface morphology controlled by randomly patterned etching and wet chemical solution etching were investigated. The surface morphology and roughness of the etched samples were examined using a spectrophotometer and a portable surface roughness (Ra) measuring instrument, respectively. The gloss caused by reflection from the glass surface was measured at $60^{\circ}$ using a gloss meter. The surface of the sample etched by the doctor-blade process was more uniform than that obtained from a screen pattern etching process at gel state etching process of the first step. The surface roughness obtained from the randomly patterned etching process depended greatly on the mesh size, which in turn affected the grain size and pattern formation. The surface morphology and gloss obtained by the etching process in the second step depended primarily on the mesh size of the gel state etching process of the first step. In our experimental range, the gloss increased on decreasing the grain size at a lower mesh size for the first step process and for longer reaction times for the second step process.

연마 과정에 따른 열중합 의치상 레진의 표면 거칠기 평가 (Evaluation of surface roughness of heat-polymerized denture base resin according to the polishing step)

  • 황성식;임용운;김시철;한민수
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.205-212
    • /
    • 2015
  • Purpose: The objective of this study was to compare the surface roughness according to polishing process in conventional laboratory techniques used for polishing three different acrylic denture base resins. Materials and methods: Specimen preparation and surface polishing procedures were conducted to manufacturer's recommendation with three heat-polymerized denture base resins. Surface roughness and gloss were measured by a contact type tester and a LED gloss checker using thickness 2 mm and diameter 10 mm. There were five specimens for each acrylic resin material and polishing procedures. Mean average surface roughness (Ra) values of each specimen group were analyzed using a one-way ANOVA analysis of variance and Scheffe's post hoc test. Surfaces after surface roughness and gloss testing according to each polishing process were evaluated under a stereoscopic microscope. Results: The highest mean average surface roughness was measured($Ra=2.43{\pm}0.47$) for surfaces finished with a denture tungsten carbide bur in Triplex. The lowest surface roughness values ($Ra=0.11{\pm}0.07$) were determined in Vertex polished with a lathe. In addition, all materials revealed that surface roughness determined highly in HP1 and HP2 than other procedures. All correlation between surface roughness and gloss showed highly with three heat-polymerized resins. Specially, topmost correlation revealed than other material in Triplex. Significant differences in mean average surface roughness were found between polishing process used high speed lathe and low speed hand-piece. Conclusion: Laboratory polishing used to high speed was found to produce the smoothest surface of heat-polymerized denture base acrylic resin. Therefore, we recommended that high polishing process need to get smooth surface.

A Review of the Topographical Causes of Gloss Variation and the Effect on Perceived Print Quality

  • MacGregor, Michael A.
    • 펄프종이기술
    • /
    • 제32권5호
    • /
    • pp.26-43
    • /
    • 2000
  • It is well accepted that gloss variation deteriorates the print quality and there are various objective ways to measure this. Several studies now have shown that the coefficient of variation in the octave band passed printed gloss image has an excellent correlation with ratings by an expert panel using a magnitude estimation scaling method. The correlation improves when the gloss level is also taken into account beyond that of the COV. There is also evidence that the correlation would improve even more if the gloss spatial distribution could be better accounted for. We show that much (at least 80% and perhaps up to 90%) of the gloss distribution can be accounted for by the paper topography over a wide range of dimensions (scale). Recent work has supported the role that microroughness and multiple surface scattering play in the gloss distribution. This offers the promise of showing that even a greater amount of gloss variationcan be explained by topography.

  • PDF

디스플레이 커버 글라스의 표면 처리에 의한 광학요소 제어 (Optical Properties Control by Surface Treatment on Display Cover Glass)

  • 김성수;황재석;전법주
    • 한국전기전자재료학회논문지
    • /
    • 제28권9호
    • /
    • pp.607-614
    • /
    • 2015
  • To provide the clear images from the direct light on electrical board and display devices, anti glare treatment of display cover glass is needed. In this study, the effects of surface treatment temperature, concentration, and etching solution coating thickness of the gel phase on optical elements control such as gloss, haze of reflected light and transmittance, were investigated. Cover glasses were treated at different coating thickness and additive concentration. The optical properties were examined using spectrophotometer, gloss and haze meter. The surface morphology and roughness were measured by the optical microscope and Ra measuring instrument. The etching rate and surface morphologies were dramatically affected by the concentration of acid additive in the viscous gel because of re-crystallization of components in the etching solution, hydrogel formation and coagulant after coating on glass substrate. In our experimental range, cover glass which is surface-treated with various optical properties as well as the morphology uniformity was obtained; in particular, optical properties could be controlled by etching solution coating thickness of the gel phase and the concentration of additive. The gloss was depended on the surface roughness and it showed the linear relationship between optical transmittance and haze of reflected light, respectively.

캘린더 처리조건이 도공지 품질에 미치는 영향 (Effect of Calendering Variables on the Properties of Coated paper)

  • 이용규;김창근;이광섭
    • 펄프종이기술
    • /
    • 제33권2호
    • /
    • pp.49-57
    • /
    • 2001
  • This study was performed to identify the effect of calendering variables on the properties of coated paper such as sheet gloss, surface roughness, opacity, etc. The effect of calendering variables including the number of nips, pressure, machine speed and moisture content on the properties of coated paper was investigated. The calender was installed with two steel rolls and one cotton-made roll. With this calender, the coated sheets were passed through the calender from 1 to 4 times, applying the linear pressure on calender rolls, 5 through 100kg/cm and operating the machine speed 3 to 12m/min. Also, the moisture content of coated sheet was varied about 5 and 10%. It was found that sheet gloss and surface roughness of coated paper was increased with increasing the number of passing nips, linear roll pressure and the moisture content of coated paper. But it was shown that the opacity and brightness of coated paper were decreased under the above conditions due to the blackening. It was also suggested that the soft nip possibly increased the thermoplasticity of coating layer with the heat of steel roll, resulting in the reinforcement of surface properties positively. The sheet gloss and surface roughness of coated paper could be improved by the longer dwell time over the rolls.

  • PDF