• Title/Summary/Keyword: Surface function

Search Result 4,536, Processing Time 0.036 seconds

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

The Predictors of Effectiveness on Urokinase Instillation Therapy into Loculated Pleural Effusion. (소방이 형성된 흉막질환에서 유로키나제 주입치료의 예후인자)

  • Song, Kee-San;Bang, Jei-So;Kwak, Seung-Min;Cho, Chul-Ho;Park, Chan-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.621-628
    • /
    • 1997
  • Background : As the pleural inflammation progresses, exudative pleural fluid becomes loculated rapidly with pleural thickening. Complete drainage is important to prevent pleural fibrosis, entrapment and depression of lung function. Intrapleural urokinase instillation therapy has been advocated as a method to facilitate drainage of gelatinous pleural fluid and to allow enzymatic debriment of pleural surface. This study was designed to investigate the predictors of effectiveness of intrapleural urokinase in the treatment of loculated pleural effusion. Method : Thirty-five patients received a single radiographically guided pig-tail catheter ranging in size from 10 to 12 French. Twenty-two patients had tuberculous pleural effusions, and 13 had non-tuberculous postpneumonic empyemas. A total of 240,000 units of urokinase was dissolved in 240 ml of normal saline and the aliquots of 80mL was instilled into the pleural cavity via pig-tail catheter per every 8hr. Effectiveness of intrapleural urokinase instillation therapy was assessed by biochemical markers, ultrasonography, and technical details. A greater than 50% improvement on follow-up chest radiographs was defined as success group. Result : Twenty-seven of 35 (77.1%) patients had successful outcome to urokinase instillation therapy. Duration of symptoms before admission was shorter in success group ($11.8{\pm}6.9day$) than in failure group ($26.62{\pm}16.5day$) (P<0.05). Amount of drained fluid during urokinase therapy was larger in success group ($917.1{\pm}392.7ml$) than in failure group ($613.8{\pm}259.7ml$) (P<0.05). Pleural fluid glucose was higher in success group ($89.7{\pm}35.9mg/dl$) than in failure group ($41.2{\pm}47.1mg/dl$) (P<0.05). Pleural fluid LDH was lower in success group ($878.4{\pm}654.3IU/L$) than in failure group ($2711.1{\pm}973.1IU/L$) (P<0.05). Honeycomb septated pattern on chest ultrasonography was observed in six of eight failure group, but none of success group (P<0.05). Conclusion : Longer duration of symptoms before admission, smaller amount of drained fluid during urokinase therapy, lower glucose value, higher LDH value in pleural fluid examination, and honeycomb septation pattern on chest ultrasonograph were predictors for failure group of intrapleural urokinase instillation therapy.

  • PDF

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report (회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례)

  • Lee, Ji-Hye;Lim, So-Min;Jung, Hye-Eun;Park, Chan-Jin;Cho, Lee-Ra;Kim, Dae-Gon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.209-222
    • /
    • 2011
  • Missing anterior teeth can be replaced using any of a number of methods. Patients may choose to replace missing teeth with a prosthesis that is either removable, fixed, or retained with implants. For patients faced with financial, anatomical, and/or esthetic limitations, the edentulous region can be restored successfully and esthetically with a properly designed and fabricated rotational path RPD. The rotational path RPD is a partial removable dental prosthesis that incorporates a curved, arcuate, or variable path of placement allowing one or more of the rigid components of the framework to gain access to and engage an undercut area. The rigid retainer must gain access to the infrabulge portion of the tooth by rotating into place. Either a minor connector or proximal plate provides retention through its intimate contact with a proximal tooth surface. A specially designed dovetails or asymmetric rest seats provides support and embracing effects. Correctly designed and fabricated rotational path RPD can provide improved esthetics, cleanliness, and retention. But rotational path RPDs are technique sensitive since the rotational path RPD has little margin of laboratory error that rigid retainers cannot be adjusted like conventional clasps can, RPD framework must be remade once the retention is lost. The sufficient understanding of the concept for the rotational path RPD is required for clinically successful treatment. This clinical report describes in detail the theoretical, laboratory considerations and the treatment of a patient with an anterior maxillary edentulous area treated by an AP path rotational RPD that had a difficulty in long term maintenance and describes another clinical case in which more reasonable treatment procedures were approached after analyzing the former case.

Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins (CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교)

  • Lee, Dong-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.183-195
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the flexural strength of CAD/CAM denture base resins with conventional denture base resins based on their thicknesses. Materials and Methods: For the conventional denture base resins, Lucitone 199® (C-LC) was used. DIOnavi - Denture (P-DO) and DENTCA Denture Base II (P-DC) were taken for the 3D printing denture base resins. For the prepolymerized PMMA resins, Vipi Block Gum (M-VP) and M-IVoBase® CAD (M-IV) were used. The final dimensions of the specimens were 65.0 mm x 12.7 mm x 1.6 mm / 2.0 mm / 2.5 mm. The 3-point bend test was implemented to measure the flexural strength and flexural modulus. Microscopic evaluation of surface of fractured specimen was conducted by using a scanning electron microscope (SEM). After testing the normality of the data, one-way ANOVA was adopted to evaluate the differences among sample groups with a significance level of P = 0.05. The Tukey HSD test was performed for post hoc analysis. Results: Under the same thicknesses, there are significant differences in flexural strength between CAD/CAM denture base resins and conventional denture base resins except for P-DO and C-LC. M-VP showed higher flexural strength than conventional denture base resins, P-DC and M-IV displayed lower flexural strength than conventional denture base resins. Flexural modulus was highest in M-VP, followed by C-LC, P-DO, P-DC, M-IV, significant differences were found between all materials. In the comparison of flexural strength according to thickness, flexural strength of 2.5 mm was significantly higher than that of 1.6 mm in C-LC. Flexural strength of 2.5 mm and 2.0 mm was significantly higher than that of 1.6 mm in P-DC and M-VP. In M-IV, as the thickness increases, significant increase in flexural strength appeared. SEM analysis illustrates different fracture surfaces of the specimens. Conclusion: The flexural strength of different CAD/CAM denture base resins used in this study varied according to the composition and properties of each material. The flexural strength of CAD/CAM denture base resins was higher than the standard suggested by ISO 20795-1:2013 at a thickness of 1.6 mm or more though the thickness decreased. However, for clinical use of dentures with lower thickness, further researches should be done regarding other properties at lower thickness of denture base resins.

Aesthetic Landscape Assessment Based on Landscape Units in the Han River Riparian Area (경관단위 기반 수변환경의 심미적 평가 - 한강 수변을 대상으로 -)

  • Bae, Min-Ki;Park, Chang-Sug;Oh, Chung-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.1
    • /
    • pp.43-56
    • /
    • 2012
  • The purpose of this study was to propose management strategies through aesthetic landscape assessments for landscape units in the Han River riparian(HRR) area. First, this research reclassified the HRR into "natural," "artificial," "agricultural," and mixed landscape types and selected 37 representative case areas(about $1km{\times}1km$). This study found 71 landscape units in consideration of topography and land surface classification. Landscape assessment consisted of landscape quality and landscape integration assessment. The criteria for assessing landscape quality were "naturalness," "interest," "uniqueness," and "landscape function." "Landscape quality" was ranked into five grades using a matrix. The landscape integration assessment consisted of an inner integration assessment in each landscape unit and outer integration assessment among landscape units. As a result of the field study, case sites were found to have 4,288 landscape units and an area of $42.8km^2$. The forest area was found to have the most space with $11,580,905m^2$(27.1%), while the wet lands had just $52,348m^2$(0.1%). In the landscape quality assessment, about 30.5% of the total area consisted of landscape units that scored highest in "naturalness". In the landscape integration assessment, about 39.3% of the total area consisted of landscape units which scored highest in "integration", denoting visual interrelation and harmony. The existence of disparities in landscape quality in accordance with the form of the landscaping was determined using a Oneway ANOVA, with "naturalistic" landscaping scoring the highest and "artificial" landscaping scoring lowest. This study may contribute to making the HRR area a more ecologically sound and visually attractive landscape space. It is recommended that the aesthetical and ecological value of the landscape unit should be assessed simultaneously in the future.

The Scale-dependent of Hydraulic Conductivity in Leaky Confined Aquifer with High Permeability at the Ttaan Isle, Gimhae City (김해 딴섬의 고투수성 누수 피압대수층에서 수리전도도의 규모종속효과)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kim, Byung-Woo;Kwon, Byung-Hyuk
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • Pumping test was conducted to understand hydraulic conductivity for leaky confined aquifer with high permeability. Test aquifer was formed in $25{\sim}35\;m$ below ground surface at predetermined site of riverbank filtration which junction of Nakdong river and Milyang river in the Ttaan isle, Gimhae city, Korea Monitoring wells were located at intervals of 2 m and 5 m from pumping well in south-west direction (MW1 and MW2 wells) and northeast direction (MW3 and MW4 wells), respectively. Pumping test was continuously conducted for constant pumping rate of $2,500m^3/day$, hydraulic conductivity was estimated using AQTESOLV 3.5 program. Hydraulic conductivity were estimated to be $1.745{\times}10^{-3}m/sec$ for pumping well (PW), $2.452{\times}10^{-3}m/sec$ for between PW and MW1 wells, $2.161{\times}10^{-3}m/sec$ for between PW and MW2 wells, $2.270{\times}10^{-3}m/sec$ for between PW and MW3 wells and $2.591{\times}10^{-3}m/sec$ for between PW and MW4 wells. The function of hydraulic conductivity (K) as monitoring distance (d) were estimated to be logK = 0.0693logd - 2.671 for south-west direction (PW-MW1-MW2 line), logK = 0.0817logd - 2.655 for north-east direction (PW-MW3-MW 4 line). Scale exponent of hydraulic conductivity as test volume was estimated using Schulze-Makuch et al.(1999) method. Scale exponent of this aquifer was estimated to be 0.15. It means that test aquifer has very low heterogeneity. The radius of influence estimated using transmissivity, maximum groundwater level displacement, distance from pumping well and pumping rate during pumping test were 7.148 m for south-west direction and 6.912 m for north-east direction. The increasing rate of hydraulic conductivity from pumping well to maximum radius of influence were estimated to be 1.40 times for south-west direction and 1.49 times for north-east direction. Thus, heterogeneity of test aquifer was a little higher in north-east direction.

A Numerical and Experimental Study for Fry-drying of Various Sludge (슬러지 유중 건조에 대한 전산 해석 및 실험적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Kim, Byeong-Gap;Hwang, Min-Jeong;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • The basic principle of fry drying process of sludge lies in the rapid pressure change of sludge material caused by the change of temperature between oil and moisture due to the difference of specific heat. Therefore, the rapid increase of pressure in drying sludge induces the efficient moisture escape through sludge pores toward heating oil media. The object of this study is to carry out a systematic investigation of the influence of various parameters associated with the sludge fry drying processes on the drying efficiency. To this end, a series of parametric experimental investigation has been made together with the numerical calculation in order to obtain typical drying curves as function of important parameters such as drying temperature, sludge diameter, oil type and sludge type. In the aspect of frying temperature, especially it is found that the operation higher than $140^{\circ}C$ was favorable in drying efficiency regardless of type of waste oil employed in this study. The same result was also noted consistently in the investigation of numerical calculation, that is, in that the sludge particle drying was efficiently made over $140^{\circ}C$ irrespective of the change of particle diameter. As expected, in general, the decrease of diameter in sludge was found efficient both experiment and numerical calculation in drying due to the increased surface area per unit volume. In the investigation of oil type and property, the effect of the viscosity of waste oil was found to be more influential in drying performance. In particular, when the oil with high viscosity, a visible time delay was noticed in moisture evaporation especially in the early stage of drying. However, the effect of high viscosity decreased significantly over the temperature of $140^{\circ}C$. There was no visible difference observed in the study of sludge type but the sewage sludge with a slightly better efficiency. The numerical study is considered to be a quite useful tool to assist in experiment with more detailed empirical modeling as further work.

Assessment of the Wetland Soil Development in Constructed Wetlands using the Soil Properties of a Reference Wetland (기준습지 토양특성을 활용한 인공습지의 토양발달 평가)

  • Lee, Ja-Yeon;Kang, Dae-Seok;Sung, Ki-June
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • Changes in wetland soil properties of two constructed wetlands after their constructions were compared to those of a natural wetland to determine if they could be used for the evaluation of the success of constructed wetlands and the assessment of their functions. One natural wetland as a reference wetland and two constructed wetlands(treatment wetland and experimental wetland) with different contaminant inflow characteristics were selected for this study. Major physicochemical properties of wetland soil such as soil texture, water content, pH, CEC(cation exchange capacity), organic matter content, total nitrogen, and available phosphorus were monitored to investigate the effects of inundation and accumulation of organic matters and nutrients on the wetland soil development. There was a clear difference in soil texture between the natural wetland and the constructed ones, with the high sand content in the constructed wetlands as compared to the high clay content in the natural one. Gradual increases of silt and clay contents over time were observed in the constructed wetlands. The soil of the natural wetland was higher in water content and organic matter but lower in pH than those of the constructed wetlands. The pH of the constructed wetlands reached near neutral ranges after initial increase. CEC and nutrient concentrations of the constructed wetlands seemed to be affected mainly by outside inflows of organic matter and contaminants. Concentrations of organic matter and nutrients decreased over time in the experimental wetland where surface and deep soils with different characteristics were mixed during its construction, suggesting that changes in soil properties during wetland constructions may affect the development of wetland soils or wetland biogeochemistry. This study showed that changes in physicochemical properties of soils in constructed wetlands could be used to assess the success of constructed wetlands and their functions, and also the importance of reference wetlands for the appropriate assessment.

Specific Absorption Coefficients for the Chlorophyll and Suspended Sediment in the Yellow and Mediterranean Sea (황해와 지중해에서의 클로로필 및 부유입자의 비흡광계수 연구)

  • 안유환;문정언
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.4
    • /
    • pp.353-365
    • /
    • 1998
  • Light absorption coefficient per unit mass of particles, i.e., specific absorption coefficient, is important as one of the main parameters in developing algorithms for ocean color remote sensing. Specific absorption coefficient of chlorophyll ($a^*_{ph}$) and suspended sediment ($a^*_{ss}$) were analyzed with a spectrophotometer using the "wet filter technique" and "Kishino method" for the seawater collected in the Yellow and Mediterranean Sea. An improved data-recovery method for the filter technique was also developed using spectrum slopes. This method recovered the baselines of spectrum that were often altered in the original methods. High $a^*_{ph}({lambda})$ values in the oligotrophic Mediterranean Sea and low values in the Yellow Sea were observed, ranging 0.01 to 0.12 $m^2$/mg at the chlorophyll maximum absorption wavelength of 440 nm. The empirical relationship between $a^*_{ph}$(440nm) and chlorophyll concentrations () was found to fit a power function ($a^*_{ph}$=0.039 $^{-0.369}$), which was similar to Bricaud et al. (1995). Absorption specific coefficients for suspended sediment ($a^*_{ss}$) did not show any relationship with concentrations of suspended sediment. However, an average value of $a^*_{ss}$ ranging 0.005 - 0.08 $m^2$/g at 440nm, was comparable to the specific absorption coefficient of soil (loess) measured by Ahn (1990). The morepronounced variability of $a^*_{ss}$ than $a^*_{ph}$ was determined from the variable mixing ratio values between particulate organic matter and mineral. It can also be explained by a wide size-distribution range for SS which were determined by their specific gravity, bottom state, depth and agitation of water mass by wind in the sea surface.