• Title/Summary/Keyword: Surface freezing

Search Result 318, Processing Time 0.035 seconds

A study on the optimum condition of electric snow melting and deicing system for the anti-freezing testing road (시험 선로 결빙 방지를 위한 전기 가열식 융설 및 융빙 시스템의 최적 조건에 관한 연구)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.4
    • /
    • pp.362-369
    • /
    • 2008
  • The snow melting system by electric heating wires which is adopted in this research is a part of road facilities to keep surface temperature of the road higher than freezing point of water for melting the snow accumulated on it. The electric heating wires are buried under paved road at a certain depth and operated automatically and manually. Design theory, amount of heating, and installation standard vary according to economic situation, weather condition, installation place and each country applying the system. A main purpose of this study is figuring out the appropriate range of required heat capacity and installation depth and pitch for solving snowdrifts and freezing problems with minimum electric power consumption. This study was performed under the ambient air temperature($-2^{\circ}C$, $-5^{\circ}C$), the pitches of the electric heating wires(200 mm, 300 mm), heating value($250\;W/m^2$, $300\;W/m^2$, $350\;W/m^2$).

Physical and Mechanical Characteristics of the Antarctic Rocks Exposed to the Extreme Environment (극한환경에 노출된 남극 암석의 물리적·역학적 특성)

  • Kim, Kiju;Kim, YoungSeok;Hong, Seung Seo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.275-284
    • /
    • 2012
  • The Antarctic continent exposed to strong wind, very low temperature, and extremely dry condition. The freezing-thawing cycles under this extreme environment change the mechanical characteristics of rocks near the ground surface. To investigate the effect of freezing-thawing cycles under the extreme environment understand on geotechnical properties of rocks, rocks from the Antarctica were collected from two places: (1) West Antarctic Cape Burks and (2) East Antarctic Terra Nova Bay areas. The rock characteristics of these two areas were described and compared. For Terra Nova Bay area, rock characteristics of rocks near the surface and depths exceeding 2.9 m were examined. The 'near-the-surface rocks' averages of absorption rate, P-wave velocity, and unconfined compressive strength were 0.56%, 3,717 m/s, and 109MPa, respectively; while, those values of 'deep-sited rocks' were 0.24%, 4,670 m/s, and 88MPa. From the measurements, it was found that the effects of weathering were not significant on mechanical characteristics (strength) but were pronounced on physical characteristics(absorption and P-wave velocity).

The Evaluation of Surface Scaling and Resistance of Concrete to Frost Deterioration with Freezing-Thawing Action by Salt Water (염화물이 함유된 동결수의 동결융해 작용에 따른 콘크리트의 내동해성과 표면열화 평가)

  • Kim, Gyu-Yong;Kim, Moo-Han;Cho, Bong-Suk;Lee, Seung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.143-151
    • /
    • 2007
  • This study presents the experimental results of frost durability including resistance to freezing-thawing and surface scaling of concrete. Mixing design was proportioned with the various water-binder ratio between 0.37 and 0.47 and three different binder compositions corresponding to Type I cement without any supplementary cementitious materials(OPC), Type II cement with 50% blast-furnace slag replacement(BFS50), and ternary cement with Type III cement, 15% fly ash, and 35% slag replacement (BFS35%+FA15%). Test results showed that the mixing design with BFS50% and BFS35%+FA15% exhibited higher durability factor than that made with OPC only. Finally, the use of blend cement containing slag can be used effectively in terms of frost durability of the concrete exposed to severe condition under coastal environment like as flying salt, sea water spray, etc.

A Study on the Sliding Characteristics of Infilling-joint Surface (충전절리면의 미끄러짐특성에 관한 연구)

  • Lee, Jung-Yub;Park, Yeong-Mog;Kim, Jae-Seok;Koo, Ho-Bon;Baek, Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.499-502
    • /
    • 2003
  • The purpose of this study is to understand the sliding characteristics of the infilling-joint surface using the new devised shear test apparatus with changeable slope for the original infilling materials and the infilling materials experienced cyclic freezing-thawing processes. Three types of the mother rock classified as the igneous rock, the metamorphic rock and the sedimentary rock and the infilling materials were collected for laboratory test. The cohesion according to the slope change of the rock joint shows large variation within ${\pm}$5 degrees but the internal friction angle shows appears the linear decreasing tendency. It is confirmed that the affecting factor of slope change of rock joint at the behavior of rock mass is larger than that of the infilling thickness. Test results show that the cohesion and the internal friction angle in 100 times of cyclic freezing-thawing processes are decreased about 50 percent compared with original one. A further study using various infillings materials would lead to a better understanding of the failure mechanism of rock mass by slope change of rock joint.

  • PDF

Evaluation of Floor Heating Performance and Design Criteria for Operating an Outdoor Swimming Pool During Winter : A Case Study (동절기 옥외 수영장 시설의 운영을 위한 바닥난방 성능평가 및 설계기준에 관한 사례연구)

  • Cho, Jinkyun;Woo, Kyunghun;Kim, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.289-296
    • /
    • 2017
  • This study aimed to analyze the deck floor heating system of an outdoor swimming pool in terms of the thermal capacity/output and the surface temperature distribution based on the outdoor temperature, to design for anti-freezing during winter. Through the transient heat transfer simulation with PHYSIBEL and theoretical equations, the surface temperature distribution of the floor heating system at two outdoor conditions in Jeju, were calculated and evaluated. The results indicate that the specific thermal output required for maintaining $4^{\circ}C$ surface temperature at the design outdoor temperature of $0.1^{\circ}C$, was about $90W/m^2$. This performance analysis can be applied for future design criteria, including optimizations of system capacity and size.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution (마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구)

  • Chang Young- Soo;Yun Won -Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

Basic Study on the Heat Transfer During Rapid Freezing of Syobean Seed by Liquid Nitrogen

  • Kawano, Toshio;Nakano, Kohei;Murata, Satoshi
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.443-452
    • /
    • 1993
  • Direct freezing tests of soybean seed by liquid nitrogen were carried out at various moisture contents and the following important conclusions were drawn from the results of temperature measurements of soybean seed and photographs of bubbles generated on its surface : 1) Assuming that the temperature gradient in a soybean seed is negligible because of its small seed size and the freezing ratio is followed the Heiss's formula, and a differential equation based on the heat energy balance was introduced . The equation was easily solved by the Runge-Kutta-Gill method and the predicted values of the temperature were in good agreement with the observed data. 2) The photographs of bubble generation during freezing showed the boiling mode was nucleate, and then the most suitable formula on the nucleate boiling heat transfer was introduced from many formulate proposed up to now by fitting the calculated values based on the formula to the observed data. The formula used for the predict on of the seed temperature was as follows: $\frac{{\partial}T_s}{\partial\theta}\;=\;-\frac{{\alpha}(T_s\;-\;T_L)^{3.3}}{W(C_s\;-\;\frac{{\delta}m(CT_s\;+\;{\sigma})}{T_s^2})}$ where C = difference of the specific heat between pure ice and water m=moisture content of soybean seed $T_s$ = seed temperature $T_L$ = Temperature of liquid nitrogen W = mass of soybean seed $\alpha$ = proportional constant $\delta$ = constant depends on variety or the type of seed $\theta$ = time $\sigma$ = latent heat of melting of pure ice This study will give important information in the hydro-freezing technique by liquid nitrogen, available as a new technique of processing agricultural products in the near future.

  • PDF

Effect of Freezing and Thawing on the Flexural Behavior of Reinforced Concrete Beams damaged by cracks (균열발생으로 손상을 입은 철근콘크리트 보의 동결융해 사이클에 따른 휨 거동 특성)

  • Jang, Yong-Heon;Yun, Hyun-Do;Seo, Soo-Yeon;Choi, Ki-Bong;Kim, Yun-Su;Kim, Sun-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.277-280
    • /
    • 2008
  • Reinforced concrete structures have an excellent durability under a good construction and continuous maintenance. But reinforced concrete construction is influenced by atmospheric phenomena and it is creating a deterioration. One of the deterioration cause on concrete is a freezing and thawing action. Freezing and thawing leads to the reduction in concrete durability by the cracking or surface spalling. If we are carried out freezing and thawing, deterioration of reinforced concrete construction will be reduction. Therefore, this study was performed to investigate the flexural behavior of reinforced concrete beams exposed to freezing and thawing cycles. Thee presence of damage and cycles were considered as variablees in this study.

  • PDF

Influence of Carbonation and Freezing-thawing on the Chloride Diffusion in Concrete (탄산화 및 동결융해 현상이 콘크리트 중의 염소이온 확산에 미치는 영향 연구)

  • Kim, Dong-Baek;Kwon, Ki-Jun;Jung, Sang-Hwa;Bok, Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.57-64
    • /
    • 2007
  • Recently, the corrosion of concrete structures has received great attention related with the deterioration of sea-side structures, such as new airport, bridges, and nuclear power plants. In this regards, many studies have been done on the chloride attack in concrete structures. However, those studies were confined mostly to the single deterioration due to chloride only, although actual environment is rather of combined type. The purpose of the present study is, therefore, to explore the influences of carbonation and freezing-thawing action to chloride attack in concrete structures. The test results indicate that the chloride penetration is more pronounced than the case of single chloride attack when the carbonation process is combined with the chloride attack. It is supposed that the chloride ion concentration of carbonation region is higher than the sound region because of the separation of fixed salts. Though the use of fly ash pronounces the chloride ion concentration in surface, amounts of chloride ion penetration into deep region decreases with the use of fly ash. The small reduction of relative dynamic elastic modulus induced from freezing-thawing increases the chloride ion penetration depths much. The present study allows more realistic assessment of durability for such concrete structures which are subjected to combined attacks of both chlorides and carbonation or freezing-thawing but the future studies for combined environment will assure the precise assessment.

Assessment of Surface Boundary Conditions for Predicting Ground Temperature Distribution (지중온도 변화 예측을 위한 지표면 경계조건 검토)

  • Jang, Changkyu;Choi, Changho;Lee, Chulho;Lee, Jangguen
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.75-84
    • /
    • 2013
  • Soil freezing is a phenomenon arising due to temperature difference between atmosphere and ground, and physical properties of soils vary upon the phase change of soil void from liquid to solid (ice). A heat-transfer mechanism for this case can be explained by the conduction in soil layers and the convection on ground surface. Accordingly, the evaluation of proper thermal properties of soils and the convective condition of ground surface is an important task for understanding freezing phenomenon. To describe convection on ground surface, simplified coefficient methods can be applied to deal with various conditions, such as atmospheric temperature, surface vegetation conditions, and soil constituents. In this study, two methods such as n-factor and convection coefficient for the convective ground surface boundary were applied within a commercial numerical program (TEMP/W) for modeling soil freezing phenomenon. Furthermore, the numerical results were compared to laboratory testing results. In the series of the comparison results, the convection coefficient is more appropriate than n-factor method to model the convective boundary condition.