• Title/Summary/Keyword: Surface effect

Search Result 16,250, Processing Time 0.045 seconds

Remineralization Effects on the Demineralized Enamel of Primary Teeth by Fluoride Varnish (불소바니쉬에 의한 탈회 유전치 법랑질의 재광화 효과)

  • Cho, Seongeun;Kim, Jongbin;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.1
    • /
    • pp.44-50
    • /
    • 2016
  • The purpose of this study was to compare and evaluate the remineralization effect of three types of fluoride varnishes on demineralized enamel of primary teeth. 40 primary teeth were decalcified by soaking them in artificial acidic solution and stored at $37^{\circ}C$ for 7 days. Then 3 varnishes - Cavity shield$^{TM}$, V varnish$^{TM}$ and MI varnish$^{TM}$ were applied respectively one time a week, for 3 weeks on the demineralized enamel surface. For the first week, MI varnish$^{TM}$ showed the highest microhardness value, V varnish$^{TM}$ was in second position, and Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference among the three groups(p > 0.05). For the second week, V varnish$^{TM}$ showed the highest microhardness value, and MI varnish$^{TM}$ came next in second position noting no significant difference (p > 0.05). Cavity shield$^{TM}$ was significantly lower than the other groups (p < 0.05). For the third week, V varnish$^{TM}$ showed the highest microhardness value, noting a significant difference from the other groups (p < 0.05). MI varnish$^{TM}$ came next, while Cavity shield$^{TM}$ showed the lowest microhardness value. However, there was no significant difference between MI varnish$^{TM}$ and Cavity shield$^{TM}$ (p > 0.05). The increase in the microhardness of groups V varnish$^{TM}$ and MI varnish$^{TM}$ were higher than that of group Cavity shield$^{TM}$ (p < 0.05), while no significant difference was noted between groups V varnish$^{TM}$ and MI varnish$^{TM}$ (p > 0.05).

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Deposition of Tear Protein according to Soft Lens Materials and The Cleaning Efficacy of Multi-purpose Solution according to the Surfactant Types (소프트렌즈 재질 별 누액단백질 침착 및 계면활성제 종류에 따른 다목적용액의 세척효율)

  • Park, Mijung;Kwon, Young Dae;Lee, Wang Jae;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the cleaning efficacy of multi-purpose solutions containing different types and content of surfactants and their effect on the visible light transmittance of soft lens. Methods: Soft lenses made of different materials (etafilcon A and hilafilcon B) were deposited tear proteins by using the artificial tear and then compared the resulting cleaning efficacy and visible light transmittance after cleaning the lens with 6 types of multi-purpose solutions containing different content of surfactants. Results: The cleaning efficacy of multi-purpose solutions was variously shown as approximately 23~43% according to the active concentration of surfactants and surface tension in multi-purpose solution when etafilcon A lens cleaned with rubbing. The highest cleaning efficacy was detected when cleaned with the multi-purpose solution containing hydrogen peroxide besides surfactant however, the amount of remaining protein was still high on the lens. After washed with multi-purpose solution, the visible light transmittance of lens was in 89.8 to 90.8%. The amount of protein deposited on hilafilcon B lens was very small compared with it on etafilcon A lens even though it was incubated in artificial tears for 7 days, which showed 5~10% of protein amount in etafilcon A lens and the decrease of visible light transmittance was also not significant. In case of rubbing with multi-purpose solution, the cleaning efficacy on hilafilcon B lens was in 45.4 to 67.4% however, the order of cleaning efficacy of multi-purpose solution was different from it on etafilcon A lens. The visible light transmittance of hilafilcon B lens has been restored to the level of new lens. Conclusions: From the result, it is concluded that the appropriate multi-purpose solution should be selected according to the lens material and the amount of protein deposit on the basis of understanding surfactants and active principle for proper care of protein deposit on soft lens and the cleaning with rubbing is more efficient for lens care regardless of manufacturer's guideline.

Physicochemical Properties of Ground Pork with Lotus Leaf Extract during Refrigerated Storage (연잎추출물 첨가가 분쇄돈육의 냉장저장 중 이화학적 품질에 미치는 영향)

  • Lee, Kyung-Soo;Kim, Ju-Nam;Jung, In-Chul
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.4
    • /
    • pp.477-486
    • /
    • 2013
  • This study was carried out to investigate the effect of lotus leaf extract on the physicochemical characteristics of ground pork stored at $4^{\circ}C$ for 10 days. Four types of ground pork were evaluated: ice water added (T0), 3% lotus leaf extract added (T1), 7% lotus leaf extract added (T2), and 10% lotus leaf extract added (T3). The pH was increased during storage, but decreased after 10 days of storage (p<0.05). The TBARS increased with a longer storage period (p<0.05), and those of T0, T1, T2 and T3 were 0.777, 0.244, 0.185, 0.182 mg MA/kg, respectively, after 10 days of storage. The VBN content of T0 and T1 increased with a longer storage period (p<0.05), but those of T2 and T3 were not significantly changed. In the case of surface color, the $L^*$ increased with a longer storage period, and that of T0 was the highest (p<0.05). The $a^*$ decreased with a longer storage period, and the $b^*$ was the highest after 1 day of storage (p<0.05). In the case of internal color, $L^*$ was not significantly changed, and $a^*$ was decreased with a longer storage period (p<0.05). The $b^*$ increased with a longer storage period (p<0.05). Water holding capacity increased with a longer storage period, and those of T2 and T3 were the highest (p<0.05). Cooking loss decreased with a longer storage period, and those of T0 and T1 were higher than those of T2 and T3 (p<0.05). Hardness and chewiness were not significantly different with a longer storage period, or among any samples.

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

A Field Survey and Analysis of Ground Water Level and Soil Moisture in A Riparian Vegetation Zone (식생사주 역에서 지하수위와 토양수분의 현장 조사·분석)

  • Woo, Hyo-Seop;Chung, Sang-Joon;Cho, Hyung-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.10
    • /
    • pp.797-807
    • /
    • 2011
  • Phenomenon of vegetation recruitment on the sand bar is drastically rising in the streams and rivers in Korea. In the 1960s prior to industrialization and urbanization, most of the streams were consisted of sands and gravels, what we call, 'White River'. Owing to dam construction, stream maintenance, etc. carried out since the '70s, the characteristic of flow duration and sediment transport have been disturbed resulting in the abundance of vegetation in the waterfront, that is, 'Green River' is under progress. This study purposed to identify the correlation among water level, water temperature, rainfall, soil moisture and soil texture out of the factors which give an effect on the vegetation recruitment on the sand bar of unregulated stream. To this purpose, this study selected the downstream of Naeseong Stream, one of sand rivers in Korea, as the river section for test and conducted the monitoring and analysis for 289 days. In addition, this study analyzed the aerial photos taken from 1970 to 2009 in order to identify the aged change in vegetation from the past to the present. The range of the tested river section was 361 m in transverse length and about 2 km in longitudinal length. According to the survey analysis, the tested river section in Naeseong Stream was a gaining river showing the higher underground-water level by 20~30 m compared to Stream water level. The difference in the underground water temperature was less than $5^{\circ}C$ by day and season and the Stream temperature did not fall to $10^{\circ}C$ and less from May when the vegetation germination begins in earnest. The impact factor on soil moisture was the underground water level in the lower layer and the rainfall in the upper layer and it was found that all the upper and lower layer were influenced by soil particle size. The soil from surface to 1 m-underground out of 6 soil moisture-measured points was sand with the $D_{50}$ size of 0.07~1.37 mm and it's assumed that the capillary height possible in the particle size would reach around 14~43 cm. On the other hand, according to the result of space analysis on the tested river section of unregulated stream for 40 years, it was found that the artificial disturbance and drought promoted the vegetation recruitment and the flooding resulted in the frequency extinction of vegetation communities. Even though the small and large scales of recruitment and extinction in vegetation have been repeated since 1970, the present vegetation area increased clearly compared to the past. It's found that the vegetation area is gradually increasing over time.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

Effect of washing methods on the quality of freshly cut sliced Deodeok (Codonopsis lanceolata) during storage (세척방법에 따른 신선편이 슬라이스 더덕의 저장 중 품질 특성 변화)

  • Choi, Duck-Joo;Lee, Yun-Jung;Kim, Youn-Kyeong;Kim, Mun-Ho;Choi, So-Rye;Cha, Hwan-Soo;Youn, Aye-Ree
    • Food Science and Preservation
    • /
    • v.20 no.6
    • /
    • pp.751-759
    • /
    • 2013
  • There is increasing interest in freshly cut products, that is, foods produced without washing and cutting. In this study, the quality of freshly cut sliced Deodeok was compared with that of what based on its washing methods. In bubble washing, the Deodeok rises to the water surface apace and is broken into centimeter sizes. Microbubble washing calls for the production of a great number of 0.1 mm-sized bubbles in anions-bearing water and their passing through a trumpet-shaped hole at a high pressure. To compare the product deterioration rates of the specimens, they were stored at $10^{\circ}C$ for 10 days. In the specimens washed with the control method and with hand washing, the deterioration rate was 80%; and in the specimens washed with bubble and microbubble washing, 20~30%. The L-value (an index of browning) was higher in the bubble and microbubble washing than in the control and the hand washing, which implies that browning was minimized during the storage. As for the viable cell and coliform group counts that were measured during the storage, the specimens washed with the control method showed the highest values. In contrast, the specimens washed with microbubble washing showed the lowest values. In the sensory test, the specimens washed with microbubble were highest in storage preference. In conclusion, the Deodeok that was stored after it was washed with microbubble washing was found to have had the best quality.

Characterization of Humic and Fulvic Acids Extracted from Soils in Different Depth: Proton Exchange Capacity, Elemental Composition and 13C NMR Spectrum (깊이별 토양 휴믹산과 풀빅산의 특성 분석: 양성자교환용량, 원소성분비, 13C NMR 스펙트럼)

  • Shin, Hyun-Sang;Lee, Chang-Hoon;Rhee, Dong-Sock;Chung, Kun-Ho;Lee, Chang-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.283-291
    • /
    • 2003
  • Humic and fulvic acids present in soils of different depth were extracted and their acidic functional groups and structural characteristics were analyzed and compared. The purpose of this study was to present a basic data needed to evaluate the effect of humic substances on depth distribution and migrational behaviour of radioactive elements deposited on soil. Acidic functional groups of the humic and fulvic acids were analyzed by pH titration method, and their proton exchange capacity (PEC, $mq\;g^{-1}$) and average $pK_a$ values were obtained. Structural characteristics of the humic and fulvic acids were analyzed using their CPMAS $^{13}C$ NMR spectra and elemental composition data. pH titration data showed that fulvic acids have higher acidic functional group contents ranging from 5.5 to $7.0meq\;g^{-1}$ compared with that of humic acids ($3.8{\sim}4.8meq\;g^{-1}$). From depth profiles, it has been found that PEC values of humic acids in deeper soil (> 8 cm) were higher than those at the surface soils. Elemental compositions (H/C ratio) and spectral features ($C_{arom}/C_{aliph}$ ratio) obtained from CPMAS $^{13}C$ NMR spectra showed that the aromatic character in humic acids was a relatively higher than that of fulvic acids, while lower in carboxyl carbon content. The aromatic character and carboxyl carbon contents of humic acids tend to increase as soil depth increased, but those of fulvic acid showed little differences by the soil depth range.

Analyses of the indispensible Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans (감마나이프 방사선수술 치료계획의 평가에 필수불가결한 지표들의 분석)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.303-312
    • /
    • 2017
  • The central goal of Gamma Knife radiosurgery(GKRS) is to maximize the conformity of the prescription isodose surface, and to minimize the radiation effect of the normal tissue surrounding the target volume. There are the various kinds of indices related with the quality of treatment plans such as conformity index, coverage, selectivity, beam-on time, gradient index(GI), and conformity/gradient index(CGI). As the best treatment plan evaluation tool, we must check by all means conformity index, GI, and CGI among them. Specially, GI and CGI related with complication of healthy normal tissue is more indispensible than conformity index. Then author calculated and statistically analysed CGI, the newly defined conformity/gradient index as well as GI being applied widely using the treatment planning system Leksell GammaPlan(LGP) and the verification method Variable Ellipsoid Modeling Technique(VEMT). In the study 10 patients with intracranial lesion treated by GKRS were included. Author computed the indices from LGP and VEMT requiring only four parameters: the prescribed isodose volume, the volume with dose > 30%, the target volume, and the volume of half the prescription isodose. All data were analyzed by paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in GI at 10 cases was observed between LGP and VEMT. Differences in GI ranged from -0.14 to 0.01. The newly defined gradient index calculated by two methods LGP and VEMT was not statistically significant either. Author did not find out the statistical difference for the prescribed isodose volume between LGP and VEMT. CGI as the evaluation index for determining the best treatment plan is not significant statistically also. Differences in CGI ranged from -4 to 3. Similarly newly defined Conformity/Gradient index for GKRS was also estimated as the metric for the evaluation of the treatment plans through statistical analysis. Statistical analyses demonstrated that VEMT was in excellent agreement with LGP when considering GI, new gradient index, CGI, and new CGI for evaluating the best plans of GKRS. Due to the application of the fast and easy evaluation tool through LGP and VEMT author hopes CGI and newly defined CGI as well as gradient indices will be widely used.