• 제목/요약/키워드: Surface diffusion

검색결과 1,613건 처리시간 0.027초

FEM 해석을 통한 표면마감재 시공 RC 구조물의 내구성 평가 (Evaluation of the Durability at RC Structure with Surface Finishing Materials using FEM Analysis.)

  • 이성민;이한승;김동석;이우진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.269-272
    • /
    • 2006
  • Chloride ion diffusion is the most important thing of occuring deterioration in RC structure. So it is important to decide the precise chloride ion diffusion coefficient in order to predict the durability life in RC structure. The purpose of this study is to analyze the established data, which are restricted by chloride diffusion coefficient, and to calculate chloride ion diffusion coefficient using RCPT test. To examine the prediction of the concrete structure durability by an FEM analysis and the chloride diffusion coefficient as a variable. Each surface finishing materials were effective on the increment of chloride penetration resistance, but showed a little different effect depending on the type of surface finishing material.

  • PDF

Vertical Diffusion of Ammonia Into Amorphous Ice Sturcture

  • 김영순;문의성;강헌
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.280-280
    • /
    • 2012
  • We examined ammonia diffusion on the surface of amorphous ice film through the measurement of decreasing residual quantity of $NH_3$ molecules compared to $H_2O$. The populations of $NH_3$ molecules on the surface of amorphous ice were monitored by using the techniques of temperature programmed reactive ion scattering (TPRIS) method. The ratio of intensity between ammonia and water was examined as a function of time at controlled temperature. When ammonia molecules were externally added onto an ice film at a temperature of 80 K, ammonia coverage with regard to ice was 0.12-0.16 ML. The intensity of ammonia molecules on the surface of ice decreased as time increased and the extent of decreased intensity of ammonia increased as controlled temperature increased. Moreover, energy barrier was estimated to be $51kJmol^{-1}$ on amorphous ice film. The results of the experiment indicate that ammonia molecules have a property of vertical diffusion into amorphous ice and the energy barrier of ammonia diffusion into bulk of ice is higher than that of hydrogen bonding.

  • PDF

W(110)면에서의 산소의 확산 : 실험과 이론의 비교 (Oxygen diffusion on W(110) : Comparison of experiment and theory)

  • 남창우;홍진표;김채옥
    • 한국진공학회지
    • /
    • 제8권3A호
    • /
    • pp.181-186
    • /
    • 1999
  • The diffusion of oxygen atoms on tungsten (110) surface is studied by comparison of experiment results and recent calculations. It has been suggested that the thermodynamic factor which is inversely proportional to be compressibility has strong temperature dependence which may cause non-Arrhenius behavior of diffusion coefficient. Recent experiments, however, indicate effectively no temperature dependence of this factor and support the view that non-Arrhenius behavior originates from the dynamic factor rather than the thermodynamic factor. Discrepancies in coverage dependence of physical quantities between theory and experiment are discussed.

  • PDF

고체 산화물 연료전지의 공기극 유로내 크롬 피독에 관한 전산해석 (Numerical analysis of chromium deposition through the SOFC cathode channel)

  • 박준근;배중면;이신구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.372-375
    • /
    • 2006
  • SOFC is a high temperature fuelcell with many advantages, but it also have several demerits. One of the Issues is cathode poisoning of Cr coming from stainless steel interconnects. Diffusion process of Cr evaporated from the surface of interconnect steel was calculated by using CFD technique to understand factors for Cr deposition. It has been cleared that factors concerned in Cr deposition and how they affect Cr deposition. Major variables for Cr deposit ion are diffusion coefficient, air velocity and temperature If diffusion coefficient decreases, Cr concentration increases in the air but decreases on the cathode surface. Increasing in air velocity, Cr concentration decreases in the air and on the cathode surface. Increase in temperature leads to rising Cr concentration on the cathode surface because of diffusion coefficient increment.

  • PDF

동(銅) 표면(表面)의 화학부식(腐蝕)에 의한 식각(蝕刻) 패턴 연구 (A Study on Etching Patterns of Copper Surface by Chemical Corrosion)

  • 김민건;서봉원
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.77-86
    • /
    • 2000
  • In order to observe the pattern forming of copper plate and chemical corrosion reaction, a study on the effect of the process parameters on the formation of micro-pattern by a photochemical etching of copper plate was carried out. The results are as follows : 1) Etching rate increases as the concentration of etchant increases under the regular condition of the temperature by the increasing of diffusion rate to surface. 2) Etching rate increases as the temperature of etchant increases by the fast acting of the material delivery of diffusion to surface under the regular condition of concentration. 3) It was found that etching speed increases as the material delivery of convection rising increased when the aeration speed of etchant increases. This result was from the fact acted by the material delivery of convection rising rather than material delivery of diffusion to the surface.

  • PDF

광전자 분광법으로 분석한 스테인레스 강 304의 산화 표면 (The Oxidized Surface of Stainless Steel 304 Analyzed with X-ray Photoelectron Spectroscopy)

  • 이경철;함경희;안운선
    • 한국표면공학회지
    • /
    • 제24권3호
    • /
    • pp.144-150
    • /
    • 1991
  • The stainless steel 304 oxidized at $70^{\circ}C$ in 2.5M CrO3/5.0M H2SO4 solution and at $200^{\circ}C$ , $300^{\circ}C$, and $400^{\circ}C$ in the air are analyzed with X-ray Photoelectron Spectroscopy (XPS) to obtain depth composition profile of the surface region. It is confirmed that the surface region has a quite different composition from that of the bulk. This is due to a difference in the outward diffusion rates of the oxidized species in the surface region. The order of diffusion rates is Fe > Cr > Ni in the experimental temperature range. In spite of the inferior rate of diffusion, Cr is enriched in the surface when it is oxidized in the CrO3/H2SO4 solution. This is due to preferential dissolution of oxidized Fe.

  • PDF

콘크리트 구조물용 표면도장공법의 차염성능의 최적화에 대한 연구 (Optimization of Surface Treatment System for Concrete Structures to Control Chloride Penetration)

  • 이창수;성재덕;윤인석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.233-236
    • /
    • 2004
  • The purpose of this paper is to evaluate performance on reducing the chloride diffusion of surface treatment systems with elapsed time, treatment thickness, treatment frequency, and the types of surface treatment - coating, penetrator, and both all. Based on this paper, the guideline to applicate surface treatment systems will be established and comprehended how effective the resistance of chloride diffusion is. The selection of surface treatment materials and thickness to acquire service life of target will be possible. It is also expected to select optimum surface treatment system groups to resist chloride diffusion effectively and to estimate increased service life as the effect of durability enhancement.

  • PDF

Comparative Measurements and Characteristics of Cu Diffusion into Low-Dielectric Constant para-xylene based Plasma Polymer Thin Films

  • Kim, K.J.;Kim, K.S.;Jang, Y.C.;Lee, N.-E.;Choi, J.;Jung, D.
    • 한국표면공학회지
    • /
    • 제34권5호
    • /
    • pp.475-480
    • /
    • 2001
  • Diffusion of Cu into the low-k para-xylene based plasma polymer (pXPP) thin films deposited by plasma-enhanced chemical vapor deposition using the para-xylene precursor was comparatively measured using various methods. Cu layer was deposited on the surfaces of pXPPs treated by $N_2$ plasma generated in a magnetically enhanced inductively coupled plasma reactor. Diffusion characteristics of Cu into pXPPs were measured using Rutherford backscattering spectroscopy (RBS), secondary ion mass spectroscopy (SIMS), cross-sectional transmission electron microscopy (XTEM), and current-voltage (I-V) measurements for the vacuum-annealed Cu/pXPPs for 1 hour at $450^{\circ}C$ and were compared. The results showed a correlation between the I-V measurement and SIMS data are correlated and have a sensitivity enough to evaluate the dielectric properties but the RBS or XTEM measurements are not sufficient to conclude the electrical properties of low-k dielectrics with Cu in the film bulk. The additional results indicate that the pXPP layers are quite resistant to Cu diffusion at the annealing temperature of $450^{\circ}C$ compared to the other previously reported organic low-k materials.

  • PDF

흡착제 크기에 따른 GAC의 멜라민 흡착 처리 : 반응속도와 분산-확산 (Treatment of Melamine by GAC Adsorption According to Adsorbent Size: Kinetics and Dispersion-Diffusion)

  • 이재엽;이상중;한인섭
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권3호
    • /
    • pp.65-72
    • /
    • 2013
  • Adsorption of melamine was examined using columns packed with granular activated carbon (GAC). Raw GAC was sieved with 20, 40, 60 and 80 mesh to determine the influence of adsorbent particle size on reaction and diffusion. The mass ratio of the adsorption capacity of GAC for melamine ranged from 9.19 to 11.06%, and adsorption rates increased with decreasing particle size within this range. Rate constants between 3.295 ~ 4.799 $min^{-1}$ were obtained using a pseudofirst-order equation that was used to determine adsorption kinetics. A surface diffusion model was adapted to take into account the unsteady-state equation of a spherical adsorbent by converting the surface concentration from a constant to a variable governed by a dispersion equation. The calculated values were fit with the experimental results by using the diffusion coefficients as regression parameters. The modified equation exhibited a more precise agreement with respect to the sum of the absolute error (SAE).

콘크리트내의 이중구조와 시간의존성을 고려한 염화물 해석기법의 개발 (Analysis Technique for Chloride Penetration using Double-layer and Time-Dependent Chloride Diffusion in Concrete)

  • 문진만;김진영;김영준;오경석;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권5호
    • /
    • pp.83-91
    • /
    • 2015
  • 콘크리트 표면의 상태에 따라 염화물은 증가 또는 감소하게 되며 이는 철근부식 및 내구수명에 매우 중요한 인자가 된다. 콘크리트의 내구성 저하를 방지하기 위해 표면함침과 같이 많은 표면강화 기술이 개발되었으나 이중 콘크리트 구조와 확산계수의 시간의존성을 고려한 염화물 해석방법은 매우 제한적이다. 본 논문에서는 표면 강화된 이중구조 콘크리트에 대해 시간의존성 확산계수를 도입하여 염화물 해석기법을 제안하였으며, 역해석을 통하여 기존의 실험결과와 비교하였다. 2년간 비말대, 해수중, 조석대 상태에 노출된 표면 함침된 콘크리트 시편에 대해 표면염화물량과 확산계수를 도출하고 Life-365에서 제안한 확산계수 식과 비교 분석하였다. 시간의존성을 고려한 결과 비말대 시편의 오차는 0.28에서 0.20 수준으로, 조석대 시편은 0.29에서 0.11 수준으로, 해수중에서는 0.54에서 0.40 수준으로 오차가 감소함을 알 수 있었다. 또한 Life365에서 사용되는 확산계수식을 사용할 경우, 과다한 확산계수로 인해 상대오차가 커지고 높은 침투깊이(e)와 낮은 확산계수비($D_1/D_2$)를 필요로 함을 알 수 있다.