• 제목/요약/키워드: Surface coil

검색결과 313건 처리시간 0.023초

고온초전도 코일의 모의 전극계에서의 절연연구 (Study on Coil Insulation of HTS Transformer with Simulated Electrode)

  • 정종만;백승명;이정원;곽동순;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.420-423
    • /
    • 2002
  • In this paper the characteristics of surface flashover for high temperature superconducting transformer(HTS) was discussed. The transformer, will be developed in the shell type with double pancake coil, isn't developed yet in the world. We conducted experiment of surface flashover that could occur in the windings of the transformer. First, we distinguished the surface flashover with electrode alignment into two type, such as parallel and vertical, and then compared with each characteristics of surface flashover. And the surface flashover with metallic particle was tested, it was also affected by the particle position. .

  • PDF

3T MR Imaging에 적합한 RF Surface Coil의 개발: 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.73-73
    • /
    • 2003
  • 목적: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다.

  • PDF

전폐형 유도전동기의 온도분포에 관한 수치 및 실험적 해석 (Numerical and experimental analysis of temperature distribution in TEFC induction motor)

  • 윤명근;고상근;한송엽;이양수
    • 대한기계학회논문집B
    • /
    • 제21권3호
    • /
    • pp.457-472
    • /
    • 1997
  • We studied the temperature distribution and heat transfer characteristics of TEFC induction motor with thermal network program for more efficient design and better cooling performance of it. We knew the characteristics and the windage loss of outer cooling fan from fan test experiments. Frame axial and peripheral heat transfer coefficients and endwinding heat transfer coefficient were measured by various model experiments and then, compared with other experimental results. Frame was the main heat transfer surface, load-side and fan-side surface were not thermally symmetric from the heat flux distribution analysis. Steady and unsteady temperature distributions were measured by real motor experiments. From the results, we knew that rotor surface temperature was higher than coil temperature and the hottest spot in the coil was loadside endwinding outside surface. We compared the simulation results with those of real motor test and the two results showed a good agreement.

High-Order Surface Gradient Coil Design Using Target Field Approach

  • Lee, J.K.;Yang, Y.J.;Jeong, S.T.;Choi, H.J.;Cho, Z.H.;Oh, C.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.19-24
    • /
    • 1996
  • 이 논문의 목적은 Target field approach방법을 사용하여 2차원적인 공간선택을 할 수 있는 고차 평면 경사 자계코일(High-Order SGC: High-Order Surface Gradient Coil)을 설계하는 것이다. 지금까지 쓰이던 원통형의 고차경사자제코일을 이용한 2차원적 원형 선택방법은 한 개의 RF Pulse로 2차원적인 공간 선택을 할 수 있는 장점이 있었으나 선택되어지는 체적의 지름이 6 ~ 8cm로 너무 크다는 단점이 있었다. 이 논문에서는 이와 같은 단점을 극복하기 위해 영상을 얻고자하는 부분에 코일을 좀 더 가까이 붙일 수 있어서 적은 전력으로 선택되어지는 체적의 지름을 1 ~ 4cm까지 줄일 수 있는 표면 고차자계코일을 Target field approach방법을 이용하여 설계하였으며 Phantom과 인체영상을 통해 제작된 코일의 성능을 확인해 보았다. 이전의 Field component 방법을 이용하여 설계한 코일에 의해서 선택되어지는 체적은 타원에 가까운 모양이 되었으나, Target field approach 방법을 이용하여 설계한 코일에 의해서 선택되어지는 체적은 이상적인 원에 가까운 모양이 되었다.

  • PDF

냉연 판재의 권취공정에 있어서 장력/열/변형 해석 (Tension/Heat/Thermal Deformation Analysis of a Cold Coiled Strip in Coiling Process)

  • 정영진;이규택;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.39-43
    • /
    • 2002
  • A new model for heat transfer and thermal deformation analysis according to strip mm in coiling process has been proposed. Finite difference analyses for heat transfer of cold rolled coil have been carried out under various coiling tensions and strip crown using the equivalent thermal conductivity for the radial direction of cold rolled coil which is a function of strip thickness, surface characteristics and compressive pressure. The compressive pressure is calculated from a equation expressed as a function of hoop stress and coil tension considering strip mm obtained by experiment. Finite element method for thermal deformation of cold rolled coil has been performed to investigate the effects of the strip crown, the coil tension and temperature. From these analyses, it is found that the axial inhomogeneity of thermal deformation is increased as the strip crown, compressive pressure, and temperature drop in cold coiled strip increase.

  • PDF

Home-built Solid-state NMR Probe for Membrane Protein Studies

  • Kim, Yong-Ae;Hwang, Jung-Hyun;Park, Jae-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권9호
    • /
    • pp.1281-1283
    • /
    • 2003
  • Proteins in highly oriented lipid bilayer samples are useful to study membrane protein structure determination. Planar lipid bilayers aligned and supported on glass slide were prepared. These stack of glass slide with planar lipid bilayers are not well fit for commercial solid-state NMR probe with round coil. Therefore, homebuilt solid-state NMR probe was built and used for a stack of thin glass plates and RF coil is wrapping directly around the flat square sample. The overall filling factor of the coil is much better and the large surface area enhances the extent to orientation by providing uniform environments for the phospholipids and the high ratio of circumference to area reduces edge effects. $^1H\;and\;^{15}N$ double resonance probe for 400 MHz NMR (9.4T) with a flat coil (coil size: 11 mm ${\times}$ 20 mm ${\times}$ 4 mm) is constructed and tested.

초전도 Coil의 새로운 turn간 절연재료의 개발 및 특성 (Development and Characteristics of a New Insulator between Turns of Superconducting Coil)

  • 박영욱;이동성;이정원;곽동순;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.26-29
    • /
    • 2002
  • Polyimide-epoxysilane (coupling agent) composites were reacted with oligomeric PDMS, a condensation product of difunctional silane, by a sol-gel process and were then dried into films. And then, the surface, mechanical, and electric properties were measured. The study showed that PDMS existed in the polymide matrix by the use of FT-IR. In the mechanical properties, the maximum elongation and toughness was increased in the polyimide with silane-groups. But the maximum tensile strength was slightly decreased. And the intensive dispersion of the silane-groups on the surface of polyimide was ascertained through XPS measurement. In the electric properties. AC break down voltage was increased by increasing the amount of difunctional silane. This experiment showed that PDMS added polyimide had better mechanical and electric properties than classical materials.

3T MR Imaging에 적합한 RF Surface Coil의 개발 : 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.48-48
    • /
    • 2003
  • Abstract: 현대 질병의 최종진단은 세포수준의 해부형태학적 연구가 일반적이며 광학현미경이나 전자현미경을 이용한 병리조직학적 소견을 바탕으로 진단되어지고 있다. 이러한 진단에는 In vivo 검사가 거의 불가능하여 주로 생검을 통한 연구만 수행되고 있어 진단함에 있어 단계적인 불편이 초래될 뿐만 아니라 악성 종양의 전이를 유발시킬 수 있고 또한 생리 및 생화학적 분석이 어렵다. 이러한 문제점을 해결하기 위해 고분해능의 RF Surface Coil을 개발하여 In vivo 및 비침습적인 방법인 MR Technology를 이용하고자 한다. Introduction: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다. Method: 고분해능의 RF Surface Coil을 제작하여 3T MR 장비에서 피부 미세구조연구에 보다 적합하도록 In vivo 및 In vitro 실험을 수행하였다. In vitro 실험은 In vivo 연구를 위한 여러 parameter들을 최적화하기 위한 기초 실험을 하였고 다양한 팬톰들을 이용하여 Tl 강조영상, T2 강조영상을 획득하였으며, SNR을 높이기 위한 개선에 대한 연구를 수행하였다. In vivo 실험은 정상피부에서 다양한 부위에 대한 피부영상의 예비 연구를 수행하였다. Result and Discussion: 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준에서 가능해짐으로써 질병의 정확한 진단이 가능해지게 될 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002)) 지원아래 수행되었다.

  • PDF

고온초전도 전동기용 계자코일의 임계전류 연구 (Study on the Critical Current of Field Coil for High Temperature Superconducting Motor)

  • 조영식;손명환;백승규;권운식;이언용;권영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.873-875
    • /
    • 2003
  • It is well known that $I_c$ (critical current) in HTS tape is more sensitive to $B{\perp}$ (magnetic field amplitude applied perpendicular to the tape surface) than to B// (magnetic field amplitude applied parallel to the tape surface). Thus, the magnitude of $B{\perp}$ at HTS tape is important to the design of HTS motor, because it determines the operating current. In addition, the $I_c$ of HTS field coil is determined by not only the $B{\perp}$ but also stress and strain condition at given operating temperature. Therefore, at the stage of field coil design, stress and strain conditions should be considered because when the HTS tape is handled, it is necessary to know the limiting values of loading, bending and twisting to avoid any damages. The $I_c$ of field coil is calculated by 3D analysis and measured through experiments considering the $B{\perp}$ and the margin of contacts loss.

  • PDF

전산해석을 통한 전대뇌동맥류 코일 색전술 후 혈류 유동 분석 (Analysis of Blood Flow after Coil Embolization in Anterior Cerebral Artery Aneurysm)

  • 김동휘;윤정훈;이창용;제준우;김동민;배영오;황진율
    • 한국가시화정보학회지
    • /
    • 제21권1호
    • /
    • pp.80-93
    • /
    • 2023
  • We performed numerical simulations of blood flow in an arterial cerebral artery aneurysm to investigate the hemodynamic behavior after coil embolization. A patient-specific model was created based on CTA data. We also conducted the coil embolization simulation to obtain the coil placement within the aneurysm. Blood was assumed to be an incompressible Newtonian fluid, and both the vessel and coil were considered rigid walls. The pulsatile boundary condition was applied at the inlet, and the outflow boundary conditions were used at the outlets. Our findings demonstrated that the coil embolization significantly reduces the blood volume flowrate entering the aneurysm by effectively blocking the inflow jet, leading to a decrease in both TAWSS and WSS, especially at the systolic peak in the impingement zone. While several high OSI regions disappeared over the aneurysm surface, we observed high OSI regions with a relatively small area where the coil did not completely occlude the aneurysm. Overall, these results quantitatively analyzed the effectiveness of coil embolization by focusing on hemodynamic indicators, potentially preventing aneurysm rupture. The present work could contribute to the development of patient-specific coil embolization.