• 제목/요약/키워드: Surface blast

검색결과 276건 처리시간 0.026초

한국과 중국간의 고로슬래그 미분말 및 플라이 애시의 품질 규정 비교 (Comparison of National Standards for Blast Furnace Slag and Fly Ash between Korea and China)

  • 후윈야오;임군수;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.63-64
    • /
    • 2022
  • In this study, the quality of mineral admixture, Comparison of blast-furnace slag(BS) and fly ash(FA)in Korea and China. In the case of BS, Korea is mainly classified into 1 type to 4 types according to the specific surface area, whereas China is classified into S105, 95, and 75 according to the activity index of 28 days of age. In the case of FA, Korea is like BS, is mainly classified into types 1 to 4 according to specific surface area, whereas China is classified into F, C (class F, class C) by ingredients and class I, II, and III according to powder and ignition loss.

  • PDF

EIS를 이용한 표면코팅 경량골재 종류별 시멘트 경화체의 계면 분석 (ITZ Analysis of Cement Matrix According to Surface Coated Lightweight Aggregate Type using EIS)

  • 김창현;정수미;김주성;박선규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.151-152
    • /
    • 2023
  • Lightweight aggregates has a dry specific gravity of 2.0 or less, which is lower than natural aggregates. Lightweght aggregate is efficient for weight reduction but has low compressive strength. In this study, EIS(electrochemical Impedance Spectroscopy) was used to confirm the ITZ(Interfacial Transition Zone) between the lightweight aggregate and cement paste according to the coated of blast furnace slag powder. As a result of EIS measurement, the correlation between ITZ characteristics and compressive strength was determined. The phase angle of EIS was different depending on the blast furnace slag powder coated of the lightweight aggregate. The surface-cotead lightweight aggregate was improved and the ITZ was strengthened.

  • PDF

Damage mechanism and stress response of reinforced concrete slab under blast loading

  • Senthil, K.;Singhal, A.;Shailja, B.
    • Coupled systems mechanics
    • /
    • 제8권4호
    • /
    • pp.315-338
    • /
    • 2019
  • The numerical investigations have been carried out on reinforced concrete slab against blast loading to demonstrate the accuracy and effectiveness of the finite element based numerical models using commercial package ABAQUS. The response of reinforced concrete slab have been studied against the influence of weight of TNT, standoff distance, boundary conditions, influence of air blast and surface blast. The results thus obtained from simulations were compared with the experiments available in literature. The inelastic behavior of concrete and steel reinforcement bar has been incorporated through concrete damage plasticity model and Johnson-cook models available in ABAQUS were presented. The predicted results through numerical simulations of the present study were found in close agreement with the experimental results. The damage mechanism and stress response of target were assessed based on the intensity of deformations, impulse velocity, von-Mises stresses and damage index in concrete. The results indicate that the standoff distance has great influence on the survivability of RC slab against blast loading. It is concluded that the velocity of impulse wave was found to be decreased from 17 to 11 m/s when the mass of TNT is reduced from 12 to 6 kg. It is observed that the maximum stress in the concrete was found to be in the range of 15 to $20N/mm^2$ and is almost constant for given charge weight. The slab with two short edge discontinuous end condition was found better and it may be utilised in designing important structures. Also it is observed that the deflection in slab by air blast was found decreased by 60% as compared to surface blast.

Effects of Air Blast Thawing Combined with Infrared Radiation on Physical Properties of Pork

  • Hong, Geun-Pyo;Shim, Kook-Bo;Choi, Mi-Jung;Min, Sang-Gi
    • 한국축산식품학회지
    • /
    • 제29권3호
    • /
    • pp.302-309
    • /
    • 2009
  • This study investigated the effects of infrared (IR) radiation combined with air blast thawing on the physical properties of pork. Regardless of air velocity, increasing IR dosage produced an exponential increase in the thawing rate of pork. This rate increased further when air blast velocity was increased. IR treatments showed significantly lower thawing loss than that of 0 Watt treatment, while increasing air velocity significantly increased thawing loss of pork (p<0.05). Increasing both IR power and air velocity tended to decrease the cooking loss of pork. Moreover, increased IR power tended to decrease the water holding capacity and shear force of pork. The shear force changes were not significant (p>0.05). Shear force also increased with increasing air velocity. In addition, the higher the air velocity the higher the shear force of pork. In Commission Internationale de l'Eclairage (CIE) colour determination, control of temperature prevented discolouration from overheating of sample surface. The results suggest that IR dosage combined with air blast has potential in thawed meat quality aspects, and that humidity control could prevent surface drying.

폭발하중을 받는 강구조 중층 건물의 응답 및 해석 (Three Dimensional Responses of Middle Rise Steel Building under Blast Loads)

  • 황영서;이완수
    • 한국전산구조공학회논문집
    • /
    • 제24권6호
    • /
    • pp.629-636
    • /
    • 2011
  • 최근 들어 여러 테러에 의한 폭발사건에서 유발된 위험상황에서 보듯이 폭발에 의한 인명피해나 시설물의 손상은 우리가 고려하는 재해수준을 넘는 비참한 결과를 항상 수반한다. 하지만 폭발에 대한 구조물의 설계는 그 연구나 대책이 상당히 미비한 실정이다. 이에 미국건물설계기준(UBC94)을 바탕으로 내진설계(Welded Moment Resistant Frame)된 10층 건물의 폭발에 대한 해석적 모델을 제공하고자 한다. 현재 폭발하중의 정량적인 결과는 미국 육군(U.S.Department of Army)에서 개발된 경험적 방법에 기반을 둔 프로그램을 통해 폭간거리에 따른 하중의 크기와 분포를 알 수 있다. 본 연구에 사용된 폭원의 성격은 반구형 표면 폭발(Hemispherical Surface Burst)의 경우를 사용하였으며, 또한 선형 및 비선형 시간 이력해석을 통해 건물의 변위, 상대변위, 요구/수행비 및 비선형 거동에 대한 해석적 결과를 제공하였다. 또한 현재 사용되고 있는 내진기준(FEMA356)에 적용하여 소성힌지의 거동을 통해 폭발에 대한 건물의 성능수준을 예상하였다.

고력볼트 접합부표면의 방식도장변수에 따른 체결력 평가 (Evaluation on Clamping Force of High Strength Bolts By Coating Parameters of Faying Surfaces)

  • 나환선;이현주
    • Corrosion Science and Technology
    • /
    • 제11권2호
    • /
    • pp.48-55
    • /
    • 2012
  • Clamping force of a high strength bolt is reduced by a certain period of time after the initial set-up. In case of special treatments on faying surfaces such as protective coating, clamping force is relaxed more severely. Tests for slip critical joints subject to various faying surface parameters were conducted. Five different surface treatments were tested including mill scale surface, blast surface, rust surface and coated surfaces. Each specimen was composed of F10T M20 of high strength bolts and steel plates. Based on the result of slip coefficient test, blast treatment surface showed 0.59, rust treatment surface showed 0.54 and inorganic zinc treatment surface exhibited 0.44. Clean mill treatment surface and red lead paint treatment surface were 0.23, 0.21 respectively. It is identified that the slip coefficient in Korean structural design guide should be determined for various surface conditions. Subsequently from long term relaxation test of ASTM A 490 high strength bolts, relaxation of no-coated surfaces such as blast, clean mill, rust treatment, the loss of initial clamping load was 10.5%, 13.6% and 7.9% for 1,000 hours, while the loss of initial clamping force was reached as 15.0%, 18.7% more than the required redundancy 10% in case of inorganic zinc and red lead painted treatment. It is required that the limit of relaxation on coated faying surface should be established separately for various surfaces.

Numerical investigation of glass windows under near-field blast

  • Chiara Bedon;Damijan Markovic;Vasilis Karlos;Martin Larcher
    • Coupled systems mechanics
    • /
    • 제12권2호
    • /
    • pp.167-181
    • /
    • 2023
  • The determination of the blast protection level and the corresponding minimum load-bearing capacity for a laminated glass (LG) window is of crucial importance for safety and security design purposes. In this paper, the focus is given to the window response under near-field blast loading, i.e., where relatively small explosives would be activated close to the target, representative of attack scenarios using small commercial drones. In general, the assessment of the load-bearing capacity of a window is based on complex and expensive experiments, which can be conducted for a small number of configurations. On the other hand, nowadays, validated numerical simulations tools based on the Finite Element Method (FEM) are available to partially substitute the physical tests for the assessment of the performance of various LG systems, especially for the far-field blast loading. However, very little literature is available on the LG window performance under near-field blast loads, which differs from far-field situations in two points: i) the duration of the load is very short, since the blast wavelength tends to increase with the distance and ii) the load distribution is not uniform over the window surface, as opposed to the almost plane wave configuration for far-field configurations. Therefore, the current study focuses on the performance assessment and structural behaviour of LG windows under near-field blasts. Typical behavioural trends are investigated, by taking into account possible relevant damage mechanisms in the LG window components, while size effects for target LG windows are also addressed under a multitude of blast loading configurations.

A Study on the EDT Characteristics of TM Work Roll and Variation of Strip Surface Roughness

  • Kim, Soon-Kyung;Moon-Kyung, Kim
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 2001
  • This paper investigates the correlation between strip surface roughness and the surface of the work roll. As the actual temper mill(TM) is used, this data will be adopted to another actual temper mill for the application and operation of this experiment. Conclusions are as follows: Electro-discharge texturing(EDT) roll has homogeneous roughness distribution and shape, and also a sinuous peak surface and the life is 2 times longer than that of shot blast texturing(SBT) method. And the higher surface roughness of work roll, the more time is necessary at the EDT method. In the SBT method without the correlation of roughness, but impeller rotation speed with an uncontrollable peak count. The roughness of SBT roll is irregularity compared to that of EDT roll because the work roll roughness is transferred to the strip which was temper rolled, and produces a more desirable image and greater clarity to the color painted steel sheet.

  • PDF

반응표면 분석법을 이용한 천연마섬유보강 순환굵은골재 콘크리트의 성능 평가 (Performance Evaluation of Natural Jute Fiber Reinforced Recycled Coarse Aggregate Concrete Using Response Surface Method)

  • 전지홍;김황희;김춘수;유성열;박찬기
    • 한국농공학회논문집
    • /
    • 제56권4호
    • /
    • pp.21-28
    • /
    • 2014
  • In this study, evaluated ware the strength and durability of the vegetated water purification channel concrete to which recycled aggregates, hawang-toh and jute were applied. Box-Behnken method of response surface analysis in statistics was applied to the experimental design. Experimental variables are as follows, recycled coarse aggregates, hawang-toh, blast-furnace slag and jute fiber. In the experiment, conducted were the tests of compressive strength, chloride ion penetration, abrasion resistance and impact resistance the replacement rate effects of the recycled aggregates, blast-furnace slag and hwang-toh on the performance of vegetated water purification channel concrete were analyzed by using the response surface analysis method on the basis of the experimental results. In addition, an optimum mixing ratio of vegetated water purification channel concrete was determined by using the experimental results. The optimum mixing ratio was determined to be in 10.0% recycled coarse aggregates, 60.0% blast-furnace slag, 10.1% hwang-toh and 0.16% jute fiber. The compressive strength, chloride ion penetration, abrasion rate, and impact number of fracture test results of the optimum mixing ratio were 24.1 MPa, 999 coulombs, 10.30 g/mm3, and 20 number, respectively.

산지별 고로슬래그미분말이 바닥용 건조시멘트 모르타르의 성능 발현에 미치는 영향에 관한 연구 (A Study on the Influence of Blast Furnace Slag from Various Areas to the Performance of surface coating Dry-Mortar)

  • 조도영;서신석;김정환;김규용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.445-446
    • /
    • 2009
  • 본 연구는 국내 고로슬래그미분말의 생산 산지별 제품에 대한 품질 성능에 대한 연구와 각 고로슬래그미분말이 바닥용 건조시멘트 모르타르 제품에 적용될 경우의 성능 발현 특징에 대하여, 기초 물성 시험과 길이변화 특성에 관하여 고찰해 보고자 한다.

  • PDF