• Title/Summary/Keyword: Surface Temperatures

Search Result 2,439, Processing Time 0.031 seconds

Effect of elevated temperatures on properties and color intensities of fly ash mortar

  • Wang, Her-Yung
    • Computers and Concrete
    • /
    • v.5 no.2
    • /
    • pp.89-100
    • /
    • 2008
  • This research examines the engineering properties and color intensities of mortar containing different amounts of fly ash (0, 5, 10 and 20%) mixed at different water-to-binder ratios (w/b = 0.23, 0.47 and 0.59) and exposed at different temperatures (T = 25, 100, 200, 400, 600 and $800^{\circ}C$). Results show that there is greater mass loss on ignition with high w/b and higher temperatures. In addition, the color channel image analyzer (Windows software written in Delphi) is utilized to study the relationship between the curing temperature and intensity of three primary colors, red, green and blue (RGB), of the fly ash mortar specimens. The results show that the RGB intensities on the specimen surface increases from that at $25^{\circ}C$. The mortar specimen becomes white with increase in w/b but without the addition of fly ash. Moreover, for mortar specimens with greater content of fly ash, red on the specimen surface has the greatest increase in intensity at elevated temperature. Observation the variations in color on the specimen surface may help estimate the highest elevated temperatures that concrete structures can withstand.

The Change of Clothing Insulation and Surface Temperature Measured by Thermography with the Ease of Pattern (의복의 여유분에 따른 단열력의 변화와 Thermogram을 활용한 의복 표면 온도 특성 분석)

  • Lee, Byung-Cheol;Hong, Kyung-Hi;Lee, Ye-Jin
    • Korean Journal of Human Ecology
    • /
    • v.19 no.6
    • /
    • pp.1045-1052
    • /
    • 2010
  • Effects of the ease of pattern on the thermal conditions of clothing were investigated through the measurement of clothing surface temperatures using infrared thermography. Four vests with different pattern ease were worn by five male subjects. Surface temperature distribution on the clothing were then examined using a thermogram to view thermo-regulating characteristics affected by the ease of pattern. Representative surface temperatures were calculated based on the percentage of the surface area within a certain temperature range and the midpoint value of the corresponding area. Representative surface temperatures matches well to the thermal insulation value measured by thermal manikin. Results indicated that representative surface temperature could be a useful quantitative value if some simple calculations were to be used alongside accurate image processing.

Numerical Analysis of Natural Convection from a Horizontal Surface Immersed in Cold Water (저온의 물속에 잠겨있는 수평 평면에 의하여 야기되는 자연대류의 수치해석)

  • 유갑종;예용택;권혁용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1195-1204
    • /
    • 1992
  • The natural convection from upward and downward facing horizontal isothermal plate immersed in water is studied numerically. The temperature of the plate is from 0.0 .deg. C to 8.0 .deg. C and the ambient water temperature is from 1.0 .deg. C to 10.0 .deg. C. Numerical results are presented for the velocity profiles, temperature profiles, local heat transfer coefficients, and average Nusselt numbers over the entire flow fields. Flow patterns are shown in the upward and downward facing surfaces at different ambient water temperatures. For the upward facing surface, there are upflow and unsteady flow. And the regions of the ambient water temperatures which give rise to the upflow are more extensive as the temperatures of the isothermal surface become more distant from the density extremum temperature. For the downward facing surface, only the downflow region is shown. For the upward facing horizontal isothermal surface, the average Nusselt number(= N $u_{1}$$^{*}$) is 28.86(Ra)$^{0.01}$. And for the downward facing surface, the average Nusselt number(= N $u_{2}$$^{*}$) is $C_{2}$(Ra)$^{0.2}$ and the values of $C_{2}$ are enlarged in the range of 0.785 .leq. $C_{2}$ .leq. 1.250 as increasing of the temperatures of the isothermal surface.ace.ace.

Trends in the Climate Change of Surface Temperature using Structural Time Series Model (구조적 시계열 모형을 이용한 기온 자료에 대한 기후변화 추세 분석)

  • Lee, Jeong-Hyeong;Sohn, Keon-Tae
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.199-206
    • /
    • 2008
  • This study employs a structural time series method in order to model and estimate stochastic trend of surface temperatures of the globe, Northern Hemisphere, and Northeast Asia ($20^{\circ}N{\sim}60^{\circ}N$, $100^{\circ}E{\sim}150^{\circ}E$). For this study the reanalysis data CRUTEM3 (CRU/Hadley Centre gridded land-surface air temperature Version 3) is used. The results show that in these three regions range from $0.268^{\circ}C$ to $0.336^{\circ}C$ in 1997, whereas these vary from $0.423^{\circ}C$ to $0.583^{\circ}C$ in 2007. The annual mean temperature over Northeast Asia has increased by $0.031^{\circ}C$ in 2007 compared to 1997. The climate change in surface temperatures over Northeast Asia is slightly higher than that over the Northern Hemisphere.

A Study for 3D Temperature Analysis between sphere and rough surface with Measured Temperatures (구와 거친표면의 미끄럼 접촉 온도해석 및 실험에 관한 연구)

  • Han T-H;Lee S-D;Kim T-W;Cho Y-J
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.97-104
    • /
    • 2003
  • The surface temperature at the interface of bodies in a sliding contact is one of the most important factors influencing the behavior of machine components. So the calculation of the surface temperature at a sliding contact interface has long been an interesting and important subject for tribologist. In this study to verify estimation of temperature rising, calculated temperatures were compared with measured temperatures. It is possible to calculate bulk and flash temperature.

  • PDF

Solid Phase Crystallization Kinetics of Amorphous Silicon at High Temperatures

  • Hong, Won-Eui;Kim, Bo-Kyung;Ro, Jae-Sang
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.2
    • /
    • pp.48-50
    • /
    • 2008
  • Solid phase crystallization (SPC) of amorphous silicon is usually conducted at around $600^{\circ}C$ since it is used in the application of flat panel display using thermally susceptible glass substrate. In this study we conducted SPC experiments at temperatures higher than $600^{\circ}C$ using silicon wafers. Crystallization rate becomes dramatically rapid at higher temperatures since SPC kinetics is controlled by nucleation with high value of activation energy. We report SPC kinetics of high temperatures compared to that of low temperatures.

Surface Reactions of Atomic Hydrogen with Ge(100) in Comparison with Si(100)

  • Jo, Sam Keun
    • Applied Science and Convergence Technology
    • /
    • v.26 no.6
    • /
    • pp.174-178
    • /
    • 2017
  • The reactions of thermal hydrogen atoms H(g) with the Ge(100) surface were examined with temperature-programmed desorption (TPD) mass spectrometry. Concomitant $H_2$ and $CH_4$ TPD spectra taken from the H(g)-irradiated Ge(100) surface were distinctly different for low and high H(g) doses/substrate temperatures. Reactions suggested by our data are: (1) adsorbed mono(${\beta}_1$)-/di-hydride(${\beta}_2$)-H(a) formation; (2) H(a)-by-H(g) abstraction; (3) $GeH_3$(a)-by-H(g) abstraction (Ge etching); and (4) hydrogenated amorphous germanium a-Ge:H formation. While all these reactions occur, albeit at higher temperatures, also on Si(100), H(g) absorption by Ge(100) was not detected. This is in contrast to Si(100) which absorbed H(g) readily once the surface roughened on the atomic scale. While this result is rather against expectation from its weaker and longer Ge-Ge bond as well as a larger lattice constant, we attribute the absence of direct H(g) absorption to insufficient atomic-scale surface roughening and to highly efficient subsurface hydrogenation at moderate (>300 K) and low (${\leq}300K$) temperatures, respectively.

Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures. (공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF

Compressive strength and failure behaviour of fibre reinforced concrete at elevated temperatures

  • Shaikh, F.U.A.;Taweel, M.
    • Advances in concrete construction
    • /
    • v.3 no.4
    • /
    • pp.283-293
    • /
    • 2015
  • This paper presents the effects of elevated temperatures of $400^{\circ}C$ and $800^{\circ}C$ on the residual compressive strength and failure behaviour of fibre reinforced concretes and comparison is made with that of unreinforced control concrete. Two types of short fibres are used in this study e.g., steel and basalt fibres. The results show that the residual compressive strength capacity of steel fibre reinforced concrete is higher than unreinforced concrete at both elevated temperatures. The basalt fibre reinforced concrete, on the other hand, showed lower strength retention capacity than the control unreinforced concrete. However, the use of hybrid steel-basalt fibre reinforcement recovered the deficiency of basalt fibre reinforced concrete, but still slightly lower than the control and steel fibres reinforced concretes. The use of fibres reduces the spalling and explosive failure of steel, basalt and hybrid steel-basalt fibres reinforced concretes oppose to spalling in deeper regions of ordinary control concrete after exposure to above elevated temperatures. Microscopic observation of steel and basalt fibres surfaces after exposure to above elevated temperatures shows peeling of thin layer from steel surface at $800^{\circ}C$, whereas in the case of basalt fibre formation of Plagioclase mineral crystals on the surface are observed at elevated temperatures.

Comparison of Land Surface Temperatures from Near-surface Measurement and Satellite-based Product

  • Ryu, Jae-Hyun;Jeong, Hoejeong;Choi, Seonwoong;Lee, Yang-Won;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.4
    • /
    • pp.609-616
    • /
    • 2019
  • Land surface temperature ($T_s$) is a critical variable for understanding the surface energy exchange between land and atmosphere. Using the data measured from micrometeorological flux towers, three types of $T_s$, obtained using a thermal-infrared radiometer (IRT), a net radiometer, and an equation for sensible heat flux, were compared. The $T_s$ estimated using the net radiometer was highly correlated with the $T_s$ obtained from the IRT. Both values acceptably fit the $T_s$ from the Terra/MODIS (Moderate Resolution Imaging Spectroradiometer)satellite. These results will enhance the measurement of land surface temperatures at various scales. Further, they are useful for understanding land surface energy partitioning to evaluate and develop land surface models and algorithms for satellite remote sensing products associated with surface thermal conditions.