• Title/Summary/Keyword: Surface Model

Search Result 10,519, Processing Time 0.048 seconds

Rayleigh-wave Phase Velocities and Spectral Amplitudes Affected by Insertion of an Anomalous Velocity Layer in the Overburden (천부 속도이상층이 레일리파 위상속도 및 수직변위 스펙트럼 진폭에 미치는 영향)

  • Kim, Ki Young;Jung, Jinhoon
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.155-162
    • /
    • 2012
  • The Thomsen-Haskell method was used to determine sensitivities of the Rayleigh-wave phase velocities and spectral amplitude of vertical ground motion to insertion of a single velocity-anomaly layer into overburden underlain by a basement. The reference model comprised a 9-m thick overburden with shear-wave velocity (${\nu}_s$ of 300 m/s above a half-space with ${\nu}_s$ = 1000 m/s. The inserted layer, with a velocity of 150, 225, 375, or 450 m/s and a thickness of 1, 2, or 3 m, was placed at depths increasing from the surface in increments of 1 m. Phase velocities were computed for frequencies of 4 to 30 Hz. For inserted layer models, we placed an anomalous layer with thickness of 1 ~ 3 m, shear-wave velocity of 150 ~ 450 m/s, and at depths of 0 ~ 8 m in the overburden. The frequency range of 8 ~ 20 Hz were the most sensitive to the difference of $C_R$ between the inserted and reference models (${\Delta}C_R$) for h = 1 m and the frequency range got wide as h increased. For all of the models, the spectral amplitudes of the fundamental mode exceeded those of the $1^{st}$-higher mode except at frequencies just above the low-frequency cutoff of the $1^{st}$-higher mode.

Monitoring of the Steaming and Drying Conditions for Onion Dehydration (건조양파 제조를 위한 증숙 및 건조 조건 모니터링)

  • Choi, In-Hag;Lee, Gee-Dong
    • Food Science and Preservation
    • /
    • v.19 no.5
    • /
    • pp.703-711
    • /
    • 2012
  • This study was conducted to investigate the quality and organoleptic properties of dehydrated onions with steaming and heating. Sliced onions were treated as follows: steaming time ($X_1$, 5~25 min); drying temperature ($X_2$, $55{\sim}70^{\circ}C$) and drying time ($X_3$, 4~20 hr). All the variables were modelled and analyzed using a central composite design and response surface methodology (RSM). The coefficients ($R^2$) of the water content and water activity model induced from RSM were 0.9514 (p<0.01) and 0.9455 (p<0.01), respectively. The water content and water activity were affected by the drying temperature and time. The $R^2$ on the models of Hunter's L, a, b values were 0.9419 (p<0.05), 0.8818 (p<0.01) and 0.9360 (p<0.01), respectively. Hunter's L, a, b values were affected by the drying temperature and time, but Hunter's b value was not affected by the steaming time. In addition, the $R^2$ on the models of overall palatability was 0.8867 (p<0.05). The maximum palatability response was 5.92 when the steaming time was 13.14 min, the drying temperature was $63.11^{\circ}C$ and the drying time was 14.49 hr.

Preparation and Characterization of Domestic Alkali-Surfactant-Polymer Solution for Enhanced Oil Recovery (국내산 계면활성제를 이용한 오일회수증진용 알칼리-계면활성제-폴리머용액의 제조 및 특성평가)

  • Lee, Sang Heon;Kim, Sang Kyum;Park, Ji Yun;Lee, Do Kyun;Hwang, Soon Choel;Bae, Wisup;Kim, In Won;Rhee, Young Woo
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.481-486
    • /
    • 2013
  • Alkali-surfactant-polymer (ASP) solution was manufactured by using the domestic surfactants for enhanced oil recovery. Domestic surfactants such as linear alkylbenzene sulfonic acid (LAS) and dioctyl sulfosiuccinate (DOSS) were used. This surfactants were purchased from AK chemtech Co., Ltd. (Korea). LAS and DOSS were blended and the ratio of LAS to DOSS are 1:1 and 2:1. Decane was used as a model compound of the crude oil. Surfactant solution and decane were blended to analyze microemulsion. Brine-oil-surfactant are mixed at varying concentration of brine from 0.8 to 3.6 wt.%. Increasing salinity causes the phase transition of microemulsion from water to middle to oil. Also, by measuring the surface tension and interfacial tension using pendent drop tensiometer and Huh's equation optimal ratio of the ASP solution was determined.

Electrospraying of Micro/Nano Particles for Protein Drug Delivery (단백질 약물 전달을 위한 마이크로/나노 입자의 전기분무 제조법)

  • Yoo, Ji-Youn;Kim, Min-Young;Lee, Jong-Hwi
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.215-220
    • /
    • 2007
  • The control of the surface energy by electrohydrodynamic force provides electrospraying with various potential advantages such as simple particle size control, mono-dispersity, high recovery, and mild processing conditions. The advantages are quite helpful to improve the stability of protein drug and control its release. Herein, the nano-encapsulation of protein drugs using electrospraying was investigated. Albumin as a model protein was processed using uniaxial and co-axial electrospraying, and chitosan, polycaporlactone (PCL), and poly (ethylene glycol) (PEG) were used as encapsulation materials. The major processing parameters such as the conductivity of spraying liquids, flow rate, the distance of electrical potential gradient, etc were measured to obtain the maximum efficiency. In the chitosan systems, mean particles size decreases as flow rate and the distance between nozzle and the collecting part decreases. In the uniaxial technique of the PCL systems, mean particles size decreases as flow rate decreases. In the coaxial technique of the PCL systems, it was found that the particles size gets larger under the application of the higher ratio of inner-to-outer liquid flow rates. The primary particles formed out of an electrospraying nozzle showed narrow particle size distribution, but once they arrived to the collecting part, aggregation behavior was observed obviously. Efficient nano-encapsulation of albumin with PCL, PEG, and chitosan was conveniently achieved using electrospraying at above 12 kV.

Thermodynamic Analysis of Phenol Adsorption by Powdered Activated Carbon (활성탄에 의한 페놀 흡착의 열역학적 연구)

  • Kim, Hwanik;Lee, Myoung-Eun;Kang, Seoktae;Chung, Jae-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.220-225
    • /
    • 2013
  • The adsorption characteristics of phenol by the powdered activated carbon (PAC) were investigated by series of batch experiments. The pseudo-second-order model described the adsorption kinetics adequately with correlation coefficients over 0.999, indicating chemical adsorption as the rate-limiting step. The kinetic rate constants were from 0.55 to 19.81 mg $mg^{-1}min^{-1}$. The adsorption isotherm followed the Langmuir isotherm, indicating the homogeneous mono-layer adsorption onto the surface of the adsorbent. The values of activation energy, enthalpy and entropy were 17.44 kJ $mol^{-1}$, -8.26 kJ $mol^{-1}$ and -18.94 J $mol^{-1}K^{-1}$, respectively. The Gibbs free energy was in the range of -2.89~-2.14 kJ $mol^{-1}$. The results show that the phenol adsorption is physical, spontaneous and exothermic reaction.

Primary Solution Evaluations for Interpreting Electromagnetic Data (전자탐사 자료 해석을 위한 1차장 계산)

  • Kim, Hee-Joon;Choi, Ji-Hyang;Han, Nu-Ree;Song, Yoon-Ho;Lee, Ki-Ha
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.361-366
    • /
    • 2009
  • Layered-earth Green's functions in electormagnetic (EM) surveys play a key role in modeling the response of exploration targets. They are computed through the Hankel transforms of analytic kernels. Computational precision depends upon the choice of algebraically equivalent forms by which these kemels are expressed. Since three-dimensional (3D) modeling can require a huge number of Green's function evaluations, total computational time can be influenced by computational time for the Hankel transform evaluations. Linear digital filters have proven to be a fast and accurate method of computing these Hankel transforms. In EM modeling for 3D inversion, electric fields are generally evaluated by the secondary field formulation to avoid the singularity problem. In this study, three components of electric fields for five different sources on the surface of homogeneous half-space were derived as primary field solutions. Moreover, reflection coefficients in TE and TM modes were produced to calculate EM responses accurately for a two-layered model having a sea layer. Accurate primary fields should substantially improve accuracy and decrease computation times for Green's function-based problems like MT problems and marine EM surveys.

Assessment of Streamflow Depletion Due to Groundwater Pumping from a Well (단일 관정 지하수 양수에 따른 하천수 감소량 평가)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.11
    • /
    • pp.1079-1088
    • /
    • 2013
  • Groundwater pumping from a well has different impacts on streamflow depletion because hydraulic properties of the aquifer and the stream bed differ depending on its location. Therefore, quantitative assessment of streamflow depletion due to each groundwater pumping with different well locations is needed for the effective groundwater development and streamflow management. In this study, a watershed-based surface water and groundwater integrated model, SWAT-MODFLOW was used to assess the streamflow depletion near stream reach due to groundwater pumping from a well located within the Sinduncheon watershed. The arbitrary 50 wells among the currently used groundwater pumping wells were selected within the study area and the streamflow responses to each groundwater pumping were simulated at nearby and downstream reaches. In particular, the applicability of the Stream Depletion Factor (SDF) and Stream Bed Factor (SBF), which are widely used for evaluating the degree of streamflow depletion due to groundwater pumping, was evaluated. The simulated results demonstrated that the streamflow depletion rate divided by the pumping rate significantly differ depending on well locations and distance between well and stream, showing a wide range of values from below 20% to above 90%. From the simulated results, it was found out that the SDF or the SBF can be a partial referred value but not an absolute criterion in determining whether a pumping well has a great impact on streamflow depletion or not.

Prediction of Optimal Microwave-assisted Extraction Conditions Preserving Valuable Functional Properties of Fluid Cheonggukjang Obtained from Red Ginseng (홍삼 첨가 액상청국장의 기능성에 대한 마이크로웨이브 최적 추출조건 예측)

  • Lee, Bo-Mi;Do, Jeong-Ryong;Kim, Hyun-Ku
    • Food Science and Preservation
    • /
    • v.14 no.5
    • /
    • pp.474-480
    • /
    • 2007
  • Response surface methodology (RSM) was employed to optimize extraction conditions preserving valuable functional properties of fluid Cheonggukjang obtained from red ginseng. Based on a central composite design, the study plan was established using variations in microwave power, ethanol concentration, and extraction time. Regression analysis was applied to obtain a mathematical model. A maximum electron donating ability (EDA) of 99.09% was obtained under the specific extraction conditions of microwave power 135.62 W, ratio of solvent to sample contents. 3.60 g/mL, and an extraction time of 11.79 min. The maximum inhibitory effect on tyrosinase activity was 10.02% at 119.16 W, 4.02 g/mL, and 5.57 min. The maximum superoxide dismutase (SOD)-like activity was 63.83% under the extraction conditions of 125.29 W, 4.04 g/mL, and 11.02 min. Based on superposition of four-dimensional RSM data obtained to optimize electron donating ability, nitrite-scavenging ability, inhibitory effect on tyrosinase activity, and SOD-like activity, the optimum ranges of extraction conditions were found to be a microwave power of $l{\sim}85 W$, a ratio of solvent to sample content of $1.4{\sim}2.8\;g/mL$, and an extraction time of $6.5{\sim}11\;min$.

Comparison of Sea Level Data from Topex/Poseidon in-situ Tide-Gauges in the East Sea (한반도 동해상에서의 Topex/Poseidon 고도자료와 현장 조위계 관측 자료의 비교연구)

  • Youn, Yong-Hoon;Kim, Na-Young;Kim, Ki-Hyun;Hwang, Jong-Sun;Kim, Jeong-Woo
    • Journal of the Korean earth science society
    • /
    • v.23 no.4
    • /
    • pp.349-356
    • /
    • 2002
  • In an effort to properly assess the validity of spaceborne radar altimeter measurements, we made a direct comparison of two different sea surface heights (SSH) acquired by both Topex/Poseidon (T/P) satellite and in-situ tide-gauges (T/G). This comparative analysis was conducted using the data sets collected from three locations along the eastern coast of Korea which include: Ulleungdo, Pohang, and Sokcho. In the course of the analysis of satellite altimeter, information of SSH was extracted from the T/P MGDR data sets through the application of both atmospheric and geophysical corrections. To compare the T/P data sets in parallel basis, the T/G data sets were averaged using the measured values within the peripheral radius of 55km. When compared among different locations, the compatibility between the two methods was much more significant in an offshore location (Ulleungdo) than the two onshore locations (Pohang, Sokcho). If the low-pass filtered results were compared among the sites, the offshore site exhibited the best correlations between the two methods (correlation coefficient of 0.91) than those of the onshore sites. These large differences in the strength of correlations among different locations are due to the deformation of M2, S2, and K1 tidal components used in the tidal model. In case of the offshore location, the compatibility of the two different methods were improved systematically by the low-pass filtering with an increase of the filtering duration such as up to 200 days.

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.