• Title/Summary/Keyword: Surface Imaging

Search Result 1,120, Processing Time 0.032 seconds

Digital Infrared Thermal Imaging of Crape Myrtle Leaves Infested with Sooty Mold

  • Kim, Jiyeon;Kweon, Si-Gyun;Park, Junhyung;Lee, Harim;Kim, Ki Woo
    • The Plant Pathology Journal
    • /
    • v.32 no.6
    • /
    • pp.563-569
    • /
    • 2016
  • The spatial patterns for temperature distribution on crape myrtle leaves infested with sooty mold were investigated using a digital infrared thermal imaging camera. The mean temperatures of the control and sooty regions were $26.98^{\circ}C$ and $28.44^{\circ}C$, respectively. In the thermal images, the sooty regions appeared as distinct spots, indicating that the temperatures in these areas were higher than those in the control regions on the same leaves. This suggests that the sooty regions became warmer than their control regions on the adaxial leaf surface. Neither epidermal penetration nor cell wall dissolution by the fungus was observed on the adaxial leaf surface. It is likely that the high temperature of black leaves have an increased cooling load. To our knowledge, this is the first report on elevated temperatures in sooty regions, and the results show spatial heterogeneity in temperature distribution across the leaf surface.

Development of serodiagnostic surface plasmon resonance imaging assay for the detection of antibodies to porcine circovirus type 2

  • Park, Chul;Kim, Bum-Seok;Kim, Yong-Hwan;Cho, Ho-Seong
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • A surface plasmon resonance imaging (SPRI) assay was developed for measuring porcine circovirus type 2 (PCV2) antibody using a recombinant capsid protein as an antigen. The diagnostic potential of SPRI for detecting antibodies to the PCV2 capsid protein was compared with that of a conventional enzyme-linked immunosorbent assay (ELISA) using 70 pig serum samples taken from 6 pig farms. There was a strong positive correlation between the SPRI and ELISA (n = 70, r = 0.911, P<0.01). Therefore, this recombinant capsid protein can be used as an antigen for serological studies, and the SPRI, a label-free and high-throughput method, is expected to be a valuable tool in the serodiagnosis of PCV2 infection.

Optimal Design of an MRI Device Considering the Homogeneity of the Magnetic Field (자기장의 균일성을 고려한 자기공명장치의 최적설계)

  • Lee, Jung-Hoon;Yoo, Jeong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.654-659
    • /
    • 2008
  • This paper is to suggest a concept design of the permanent magnet type magnetic resonance imaging (MRI) device based on the parameter optimization method. Pulse currents in the gradient coils will introduce the effect of eddy currents in the ferromagnetic material, which will worsen the quality of imaging. In order to equalize the magnetic flux in the MRI device for good imaging, the eddy current effect in the ferromagnetic material must be taken into account. This study attempts to use the design of experiment (DOE) and the response surface method (RSM) for equalizing the magnetic flux of the permanent magnet type MRI device using that the magnetic flux can be calculated directly using a commercial finite element analysis package. As a result, optimal shapes of the pole and the yoke of the PM type MRI device can be obtained. The commercial package, ANSYS, is used for analyzing the magnetic field problem and obtaining the resultant magnetic flux.

Generation of Water Droplet Ion Beam for ToF-SIMS Analysis

  • Myoung Choul Choi;Ji Young Baek;Aram Hong;Jae Yeong Eo;Chang Min Choi
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2023
  • The increasing demand for two-dimensional imaging analysis using optical or electronic microscopic techniques has led to an increase in the use of simple one-dimensional and two-dimensional mass spectrometry imaging. Among these imaging methods, secondary-ion mass spectrometry (SIMS) has the best spatial resolution using a primary ion beam with a relatively insignificant beam diameter. Until recently, SIMS, which uses high-energy primary ion beams, has not been used to analyze molecules. However, owing to the development of cluster ion beams, it has been actively used to analyze various organic molecules from the surface. Researchers and commercial SIMS companies are developing cluster ion beams to analyze biological samples, including amino acids, peptides, and proteins. In this study, a water droplet ion beam for surface analysis was realized. Water droplets ions were generated via electrospraying in a vacuum without desolvation. The generated ions were accelerated at an energy of 10 keV and collided with the target sample, and secondary ion mass spectra were obtained for the generated ions using ToF-SIMS. Thus, the proposed water droplet ion-beam device showed potential applicability as a primary ion beam in SIMS.

Local transport properties of coated conductors by laser-scan imaging methods

  • Kim, Gracia;Jo, William;Nam, Dahyun;Cheong, Hyeonsik;Moon, Seoung Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.1-4
    • /
    • 2016
  • To observe the superconducting current and structural properties of high critical temperature ($T_c$) superconductors (HTS), we suggest the following imaging methods: Room temperature imaging (RTI) through thermal heating, low-temperature bolometric microscopy (LTBM) and Raman scattering imaging. RTI and LTBM images visualize thermal-electric voltages as different thermal gradients at room temperature (RT) and superconducting current dissipation at near-$T_c$, respectively. Using RTI, we can obtain structural information about the surface uniformity and positions of impurities. LTBM images show the flux flow in two dimensions as a function of the local critical currents. Raman imaging is transformed from Raman survey spectra in particular areas, and the Raman vibration modes can be combined. Raman imaging can quantify the vibration modes of the areas. Therefore, we demonstrate the spatial transport properties of superconducting materials by combining the results. In addition, this enables visualization of the effect of current flow on the distribution of impurities in a uniform superconducting crystalline material. These imaging methods facilitate direct examination of the local properties of superconducting materials and wires.

Growth of Graphene on Electro-polished Copper Foil by Thermal CVD

  • Jin, Xiaozhan;Kim, Sung-Jin;Seo, Eun-Kyoung;Boo, Doo-Wan;Lee, Jung-Ah;Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.410-410
    • /
    • 2012
  • The continuous monolayer graphene was synthesized on electro-polished copper foil. Electro-polishing sticks off the coating layer of copper foil, which prevents the continuous graphene growth. The quality of continuous graphene is dependent on roughness of copper foil. Copper foil roughness could be controlled by changing polishing condition. The effects of working voltage (4-6 V) and time (30-70 sec) for electro-polishing were systematically examined. The change of surface roughness was checked with AFM.

  • PDF

Development of Two-Component Nanorod Complex for Dual-Fluorescence Imaging and siRNA Delivery

  • Choi, Jin-Ha;Oh, Byung-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.9
    • /
    • pp.1291-1299
    • /
    • 2014
  • Recently, multifunctional nanomaterials have been developed as nanotherapeutic agents for cellular imaging and targeted cancer treatment because of their ease of synthesis and low cytotoxicity. In this study, we developed a multifunctional, two-component nanorod consisting of gold (Au) and nickel (Ni) blocks that enables dual-fluorescence imaging and the targeted delivery of small interfering RNA (siRNA) to improve cancer treatment. Fluorescein isothiocyanate-labeled luteinizing hormone-releasing hormone (LHRH) peptides were attached to the surface of a Ni block via a histidine-tagged LHRH interaction to specifically bind to a breast cancer cell line, MCF-7. The Au block was modified with TAMRA-labeled thiolated siRNA in order to knock down the vascular endothelial growth factor protein to inhibit cancer growth. These two-component nanorods actively targeted and internalized into MCF-7 cells to induce apoptosis through RNA interference. This study demonstrates the feasibility of using two-component nanorods as a potential theranostic in breast cancer treatment, with capabilities in dual imaging and targeted gene delivery.

Development of Medical Infrared Imaging System (의료용 적외선 영상장치의 구현)

  • Lee, Soo-Yeol;Woo, Eung-Je;Cho, Min-Hyung;Song, Hyung-Bin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.17-20
    • /
    • 1993
  • With proper designs of infrared optic system and two dimensional scanning mechanism, a medical infrared imaging system has been developed. The infrared imaging system can be used for two dimensional imaging of surface temperature of human body by measuring the amount of infrared lights radiating from it. It hag been experimentally proven that the degree of temperature measurement accuracy of the developed system is under $0.1^{\circ}C$ with spatial resolution of 1 mrad, image matrix size of $256{\times}240$, and imaging time of 4 seconds.

  • PDF

Imaging Mode Design and Performance Characteristics of the X-band Small SAR Satellite System

  • Kwag, Young-Kil
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.2
    • /
    • pp.157-175
    • /
    • 2000
  • A synthetic aperture radar (SAR) system is able to provide all-weather, day-and- night superior imaging capability of the earth surface, and thus is extremely useful in surveillance for both civil and military applications. In this paper, the X-band high resolution spaceborne SAR system design is demonstrated with the key design performance for a given mission and system requirements characterized by the small satellite system. The SAR multi-mode imaging technique is presented with a critical parameter assessment, and the standard mode results are analyzed in terms of the image quality performances. In line with the system requirement X-band SAR payload and ground reception/processing subsystems are designed and the major design results are presented with the key performance characteristics. This small satellite SAR system shows the wide range of imaging capability with high resolution, and proves to be an effective surveillance systems in the light weight, high performance and cost-effective points of view.

Radiolabeled 2D graphitic nanomaterials and their possibility for molecular imaging applications

  • Kang, Seok Min;Kim, Chul Hee;Kim, Dong Wook
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2018
  • In recent years, many researchers have attempted to make use of 2D nanoparticles as molecular imaging probes since extensive investigations proved that 2D nanoparticles in the body tends to accumulate certain lesions by enhanced permeability and retention (EPR) effect. For example, graphene and carbon nitride which have high surface area and modifiable properties showed good biocompatibility and targetability when it used as imaging probes. However, poor dispersibility in physiological mediums and its uncontrolled size limited its usage in bio-application. Therefore, oxidation process and mechanical exfoliation have been developed for overcoming these problems. In this paper, we highlight the several major methods to synthesize biocompatible 2D nanomaterials like graphene and carbon nitride especially for molecular imaging study including positron emission tomography (PET).