• Title/Summary/Keyword: Surface Current

Search Result 5,713, Processing Time 0.033 seconds

Composition and microstructure of Silver-Tin alloy deposits from prophosphate bath (피로인산염욕을 사용한 은-주석 합금도금층의 조성 및 현미경 조직)

  • 예길촌;김용웅;김진수
    • Journal of the Korean institute of surface engineering
    • /
    • v.26 no.3
    • /
    • pp.143-148
    • /
    • 1993
  • Composition and microstructures of Silver-Tin alloy deposits from a pyrophosphate bath were studied under the D.C. electrolysis conditions. Cathode current efficiency and throwing power of alloy deposits de-creased with increasing current density. Tin content of Ag-Sn alloy deposits decreased noticeably with the cur-rent density and with decreasing pH. The preferred orientation of the deposits tended to change in sequence of (110)longrightarrow(111)longrightarrow(100) texture with increasing the cathode overpotential. The surface structure of alloy deposits showed the smooth surface structure with fine crystallites.

  • PDF

A Study on Uniformity of Current Distribution in Hull Cell (Hull Cell에서 전류분포의 균일화에 관한 연구)

  • 여운관
    • Journal of the Korean institute of surface engineering
    • /
    • v.27 no.6
    • /
    • pp.340-346
    • /
    • 1994
  • The method of uniforming current distribution in Hull cell are studied by using auxiliary anode, current shield bipolar electrode, and combinings bipolar electrode with current shield in order to find a way of uni-form deposition. The current density distributions are measured by each ammeter of the same inner resistance connected to divided cathode pannel respectively. The current density distributions of cathode electrode divided into five sections with 5mm width have a tendency of linear inclination, and that of twenty sections have a tendency of smoother curve than the curve of original Hull cell pannel. Their results showed lower value on the high current density portion and higher value on the low portion than that original Hull cell pannel. The current distribution in Hull cell is able to unify by using auxiliary anode, or combining bipo-lar electrode with current shield, but not efficient in using one of both individually.

  • PDF

The Effects of Surface Condition and Flow Rate to the Cathodic Protection Potential and Current on Steel (강의 음극방식에 미치는 표면상태와 유속의 영향)

  • Kyeong-soo, Chung;Seong- Jong, Kim;Myung-Hoon, Lee;Ki-Joon, Kim;Kyung-Man, Moon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.972-980
    • /
    • 2004
  • Cathodic protection is being widely used to protect steel structures in sea water environment, In order to protect steel structures completely, the flow condition of sea water surrounding with this structures and the surface condition of the structures must be considered for a desirable design of cathodic protection. In this study, the optimum protection potential and current density were investigated in terms of cathodic current density, surface condition and a flow condition of sea water. The optium protection potential of the cleaned specimen was -770 mV(SCE) and below. However in the case of the rusted specimen, its potential was -700 mV(SCE) and below, which was somewhat positive than the cleaned one irrespective of flow condition. The optimum cathodic protection current density for both the cleaned and rusted specimens was 100 mA/$\textrm{m}^2$, however, on the flow condition, 200 mA/$\textrm{m}^2$ to be supplied for cathodic protection of steel structures completely for both cleaned and rusted specimens.

The change of surface degradation properties of silicone rubber for salt fog (염무-열 반복 열화에 따른 실리콘 고무의 표면열화특성변화)

  • Oh, Tae-Seung;Lee, Chung;Park, Soo-Gil;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.886-889
    • /
    • 2001
  • Silicone rubber is being used for the housing material of outdoor high voltage insulators such as composite insulator, bushing, surge arrestor and cable terminator because of good tracking and erosion resistance, good hydrophobicity and recovery of hydrophobicity and chemical stability. But, the leakge current occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current is important to estimate the condition of the silicone rubber surface. In this paper, aging characteristics of silicone rubber used for outdoor insulation have been hydrophobicity of silicone rubber in salt fog chamber with average leakage current monitoring for observing the transformation of surface degradation properties of silicone rubber with different ATH(alumina trihydrate, A1$_2$O$_3$$.$3H$_2$O) filler contents. The experimental results show that a higher peak leakage current and to raise a long time for tracking with increasing amount of ATH by the salt fog and heat recycle ageing.

  • PDF

Surface Current Measurement by Tracking a Buoy Drifted from Mara-do (마라도에서 표류된 부이의 위치추적을 이용한 표층류의 실측정보)

  • Ryu Hwangjin;Song Museok;Jung Jinyoung;Ahn Yongho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.4
    • /
    • pp.41-47
    • /
    • 2002
  • The surface current in the region from Mara-do to mid of the Pacific has been measured by tracking the position of a buoy. The buoy was accidentally released from its original location, near Mara-do, and it has been drifting following the surface current. The tracking started on 27 December 2001 and continued until 29 June 2002. We combined the trace oi the buoy with the wind data available.

  • PDF

Effect of Cu2+ Concentration and Additives on Properties of Electrodeposited Cu Thin Films for FCCL from Sulfate Baths (황산염용액으로부터 전기도금 된 FCCL용 Cu 필름의 특성에 미치는 Cu 이온농도 및 첨가제의 영향)

  • Shin, Dong-Yul;Park, Doek-Yong;Koo, Bon-Keup
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.5
    • /
    • pp.191-196
    • /
    • 2009
  • Nanocrystalline Cu thin films were electrodeposited from sulfate baths and investigated systematically the influences of $Cu^{2+}$ concentration and additives on current efficiency, residual stress, surface morphology, and XRD patterns of electrodeposited Cu film. Current efficiency was nearly 100% at from 0.2M to 1.0 M $Cu^{2+}$ concentration. but it was linearly increased with $Cu^{2+}$ concentration at less than 0.2M. The residual stress was observed in range of 7.9 to 18.4 MPa and tensile stress mode. Dendritic and powdered form was obtained at below 0.1 M. As increased with $Cu^{2+}$ concentration in solution, the main peak in the XRD pattern shifted (111) and (220) from (200). In the other hand, all about 100% current efficiency observed in all additive concentration systems, and residual stress observed in range of 20.4 to 26.3 MPa tensile stress. The condition 5(Ultra make-up - 10 ml/l, Ulta A - 0.5ml/l, Ultr B - 0.5 ml/l) was good surface morphology, and fcc(111) peak in XRD patterns increased with increasing additive concentration.

Development of Multi-channel Eddy Current System for Inspection of Press Rolls (압연롤 검사를 위한 다중 센서 와전류 탐상 검사 시스템 개발)

  • Lee, Jae-Ho;Park, Tae-Sung;Park, Ik-Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.306-312
    • /
    • 2017
  • Press rolls are constantly exposed to physical and heat stresses on their surface and are prone to crack, bruise, and spall if the accumulated stress goes beyond the critical point. Such surface phenomenon can cause them to lose their functionality and eventually lead to a halted production line. Eddy current testing can be considered a useful method to investigate the surface of the roll. The method involves the application of a high intensity magnetic field onto the surface of the roll, and thereby finding any early stage of possible defects. When the method was applied for roll inspection, the cross section of the sensor was regulated as per the overall testing speed. A smaller cross sectional area implied a better resolution but a longer testing time. In this paper, a convenient method to increase both overall system resolution and inspection speed of eddy current roll inspection is suggested by using a devised array sensor structure.

Electrical Properties of Woodceramics with Sending an Electric Current (통전한 우드세라믹의 전기적 성질)

  • Oh, Seung Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.9-13
    • /
    • 2007
  • Using sawdust boards made of pine by differing the percentage of resin impregnation, wood-ceramics were manufactured by carbonizing temperature at $650^{\circ}C$. Their electrical properties and surface temperature were measured by sending an electric current. As electrical resistance of woodceramic was lower, its surface temperature, even in a low voltage, became higher. It seemed to be necessary to applying higher voltage to the woodceramic to raise the surface temperature by target temperature $70^{\circ}C$ or more in this study, according as resistance increased. When the voltage increased, woodceramics showed higher level all in electric current, electric power and surface temperature. Arrival time, electric current and electric power increased with increase of target temperature under constant voltage.

Analysis on Correlation Coefficient of Surface Image Velocimeter (SIV) Using On-site Runoff Image (현장유출영상을 활용한 표면영상유속계(SIV)의 상관계수 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee;Kim, Dong-Su;Kim, Seojun
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.403-414
    • /
    • 2015
  • This study is daytime and nighttime runoff image data caused by heavy rain on May 27, 2013 at Oedo Water Treatment Plant of Oedo-Stream, Jeju to compute runoff by applying Surface image velocimeter (SIV) and analyzing correlation according to current. At the same time, current was comparatively analyzed using ADCP observation data and fixed electromagnetic surface current meter (Kalesto) observed at the runoff site. As a result of comparison on resolutions of daytime and nighttime runoff images collected, correlation coefficient corresponding to the range of 0.6~0.7 was 6.8% higher for nighttime runoff image compared to daytime runoff image. On the contrary, correlation coefficient corresponding to the range of 0.9~1.0 was 17% lower. This result implies that nighttime runoff image has lower image quality than daytime runoff image. In the process of computing current using SIV, a rational filtering process for correlation coefficient is needed according to images obtained.

A Method for Evaluating Electric Shock Hazards Based on Human Body Current (인체전류를 기반으로 하는 감전의 위험성 평가방법)

  • Lee, Bok-Hee;Yoo, Yang-Woo;Choi, Jong-Hyuk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.108-114
    • /
    • 2011
  • In order to mitigate the possible hazards from electric shock due to the touch and step voltages, the high resistivity material such as gravel is often spread on the earth's surface in substations. When the grounding electrode is installed in two-layer soil structures, the surface layer soil resistivity is different with the resistivity of the soil contacted with the grounding electrodes. The design of large-sized grounding systems is fundamentally based on assuring safety from dangerous voltages within a grounding grid area. The performance of the grounding system is evaluated by tolerable touch and step voltages. Since the floor surface conditions near equipment to be grounded are changed after a grounding system has been constructed, it may be difficult to determine the tolerable touch and step voltage criteria. In this paper, to propose an accurate and convenient method for evaluating the protective performance of grounding systems, the propriety of the method for evaluating the current flowing through the human body around on a counterpoise buried in two-layer soils is presented. As a result, it is reasonable that the grounding system performance would be evaluated by measuring and analyzing the current flowing through the human body based on dangerous voltages such as the touch or step voltages and the contact resistance between the ground surface and feet.