• Title/Summary/Keyword: Support Device

Search Result 1,010, Processing Time 0.022 seconds

Device Control System based on Brain Wave Data (뇌파데이터 기반의 디바이스 제어 시스템)

  • Lee, So-Hyun;Lee, Ye-Jeong;Lee, Seok-cheol;Seo, Jeongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.813-815
    • /
    • 2016
  • This paper implements a device control system based on the brain wave data. Brain-Computer Interface (BCI) technology can pass directly to the system without going through the operation of the language or body. By controlling the device to detect brain waves in real time according to the change of status it helps to ease life for a variety of services, such as disabled people with limited mobility or students, people who need multi-tasking. In addition, it is possible to develop an application service such as the home device control system. A device control system implemented in the paper based on the data collected from the EEG Headset associated to control the power of the smart phone and audio. Control the power ON / OFF operation by the Attention, and support service functions to control the audio by the Meditation and Eye blink. It was confirmed that the device control using the brain wave data to be operated through a laboratory test successfully.

  • PDF

Current Management Status of Welfare Medical Device Center (복지용구사업소 운영 현황)

  • Chin, Young Ran;Lee, Hyo Young
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.803-814
    • /
    • 2010
  • This study was conducted to understand current management status of welfare medical device centers and to suggest complementary point. Method: We surveyed 194 welfare medical device centers through the mail. The survey was done in three domains, i. e. management of service, assuring the health resources, offering the service. Results & Conclusions: According to the result of our study, several problems, which should be improved in the near future, were suggested. That were improving facilities(especially in sanitization of the devices), operating an education or training program for the personnel, and making up for the current management. It was very important for soft landing of long-term care insurance and improving quality of the elderly's life that 'Ministry of Health and Welfare' and 'National Health Insurance corporation' must support welfare medical device centers for discharging their roles

Mobile IPv6 Session Key Distribution Method At Radius-based AAAv6 System

  • Lee Hae Dong;Choi Doo Ho;Kim Hyun Gon
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.581-584
    • /
    • 2004
  • Currently, there are many subscriber access networks: PSTN, ADSL, Cellular Network, IMT200 and so on. To these service providers that provide above network service, it is important that they authenticate and authorize legal subscribers and account for their usage. At present, There exist the several protocols that Support AAA(Authentication, Authorization and Accounting) service : RADIUS, Diameter, TACACS+. Nowadays, RADIUS has used for AAA service widely. It has been extended to support other access network environment. So, we extend RADIUS to support environment of Mobile IPv6. Mobile IPv6 uses IPsec as a security mechanism, basically. But, IPsec is a heavy security technology for small, portable, mobile device. Especially, it is serious at IKE, the subset of IPsec. IKE is a key distribution protocol that distributes the key to the endpoints of IPsec. In t:lis paper, we extend RADIUS to support environment of Mobile IPv6 and simplify the IKE phase of IPsec by AAA system distributing the keys by using its security communication channel. Namely, we propose the key distribution method for IPsec SA establishment between mobile node and home agent. The suggested method was anticipated to be effective at low-power, low computing deyice. Finally, end users feel the faster authentication.

  • PDF

Vibration Characteristic of a Cylindrical Rod according to the Mounting Locations on the Grid Support Structure (격자 지지구조체에 묶여있는 실린더 형 봉의 삽입위치에 따른 진동특성)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam;Kim, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.515-518
    • /
    • 2006
  • A vibration test for a cylindrical rod inserted on the grid support structure was tested using the sine sweep excitation method with closed loop force control. The effect of the mounting location of a test rod on the vibration characteristics of a rod continuously supported by the full size($16{\times}16$) grid support was identified. An electromagnetic vibration shaker, non-contact displacement sensor and HP/VXI data acquisition device were used and TDAS software was also used as a data sampling and processing tools. The natural frequencies and mode shape of the test rod were consistent with the previous works of a rod vibration test with partial grids($3{\times}3,\;5{\times}5\;and\;7{\times}7$). The frequency characteristics of the rod according to the mounting location were shown clear discrepancies, but mode shapes were nearly same. As the test rod closes to the bottom clamping region of the spacer grid, peak vibration amplitudes of the rod become smaller.

  • PDF

Development of Bubble Detector for Extracorporeal Circulation Support System (체외 순환 보조 장치 위한 공기방울 감지 장치 개발)

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • Extracorporeal circulation support system is a device for repiratory and heart failure treatment, and there have been many trials for development and clinical application in the world. These devices need to be careful while using is air embolism. Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity or using extracorporeal circulation support system. To solve the problem, we developed the air detector using relative dielectric constant change. In experiments with a mock circulation system, the proposed system showed a signal difference depending on the amount of air in the tube.

Design and development of in-wheel motor-based walking assistance system

  • Park, Hyeong-Sam;An, Duk-Keun;Kim, Dong-Cheol;Lee, Sang-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.371-376
    • /
    • 2022
  • The purpose of this study is to develop a walking assistance system with mobility support and life support functions so that the elderly with reduced physical ability and patients who are uncomfortable when moving can move comfortably indoors and outdoors, and help social life. An obstacle recognition sensor module that can be applied indoors and outdoors is installed on a lightweight walking aid. The purpose of this study is to develop a walking assistance system with mobility support and life support functions so that the elderly with reduced physical ability and patients who are uncomfortable when moving can move comfortably indoors and outdoors, and help social life. An obstacle recognition sensor module that can be applied indoors and outdoors is installed on a lightweight walking aid. It is a system structure of an integrated actuator and brake system that can avoid obstacles in consideration of the safety of the elderly and is easy to install on the device. In this paper, the design of a lightweight walking aid was designed to increase the convenience of the socially disadvantaged and the elderly with reduced exercise ability. In addition, in order to overcome the disadvantage of being inconvenient to use indoors due to the noise and vibration of the motor during operation, an In-Wheel type motor is applied to develop and apply a low noise, low vibration and high efficiency drive system.

The In-hospital Clinical Outcomes of Extracorporeal Life Support after Adult Cardiovascular Surgery (성인 심혈관 수술 후 시행한 체외순환보조의 조기 임상결과)

  • Yie, Kil-Soo;Na, Chan-Young;Oh, Sam-Sae;Kim, Jae-Hyun;Ryu, Se-Min;Park, Sung-Min;Cho, Seong-Joon
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.464-472
    • /
    • 2009
  • Background: We analyzed the clinical results and the factors for survival of patients who underwent extracorporeal life support system after adult cardiovascular surgery. Material and Method: We retrospectively reviewed the medical record of 44 patients (1.6% of the total adult cardiovascular surgical cases) who underwent the use of a ventricular assisted device or extracorporeal membrane oxygenation from January 2002 to August 2008. There were 32 (72.7%) males and their mean age was 61.7$\pm$14.9(range: 20$\sim$73) years old. The mean duration of extracorporeal life support system was 5.3$\pm$3.0 (range: 1$\sim$12) days. Result: Of these 44 patients, 24 (54.5%) patients were successfully weaned from the extracorporeal device. Eighteen (40.9%) survivors were able to be discharged from the hospital. Complications were noted in 38 patients (86.4%). An emergency operation, no usage of a concomitant intraaortic balloon pump and major complications during use of the extra corporeal life support system such as bleeding, flow instability and renal failure were identified as significant risk factors for poor survival on univariated analysis. Owing to educational support and a continuous renal replacement therapy system, the clinical outcomes of these patients have improved since 2006. On multivariated analysis, renal failure and bleeding during extracorporeal life support were significant risk factors for poor survival. Conclusion: Although using. extracorporeal life support systems after adult cardiovascular surgery revealed acceptable clinical results, determining the optimal treatment strategy and further well designed larger studies are needed to improve the survival rate of patients who undergo extracorporeal life support after adult cardiovascular surgery.

Structure Development of Systematic Conceptual Design Process for Designing Engineering Systems (공학 시스템 설계를 위한 체계적인 개념 설계 프로세스 구조 개발)

  • Park, Yong-Taek;Kuk, Kum-Hoan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.86-94
    • /
    • 2007
  • The design process must be planned carefully and executed systematically in order to support designers who are faced with many engineering design problems. In particular, conceptual design stage is very important than other stages such as detailed design or manufacturing stage on designing engineering systems. When designers are faced contradictory situation in task, conceptual design usually requires inventive thinking which depends on their creativity. And in order to develop good concepts, it is necessary to resolve contradictory situations during conceptual design. This paper presents a structure of systematic conceptual design process for designing engineering systems. And we developed the automatic feeding screw device using the proposed design process structure.

Development of Embedded System Based on Windows CE 5.0 (S3C2410A와 Windows CE 5.0 기반의 임베디드시스템 개발에 관한 연구)

  • Kim, Do-Kyu
    • The Journal of Information Technology
    • /
    • v.8 no.4
    • /
    • pp.91-102
    • /
    • 2005
  • In this paper, development of embedded system based on Windows CE 5.0 which released recently is studied. Embedded softwares for the target board using S3C2410A SOC based on ARM920T core are composed of (1) BSP(Board Support Package) contains an OAL(OEM Adaptation Layer) which includes a boot loader for initializing and customizing target hardware, device drivers, and a corresponding set of configuration files (2) Windows CE 5.0 kernel (3) SDK and MP3 test application. Particularly, PB(Platform Builder) provides the efficient functions to build, test and debug the BSP and CE kernel. It is looked forward to being widely spread that Windows CE 5.0 will be utilized at smart devices such as PMP, CNS and DMB phone which inevitably require a display device.

  • PDF

Wireless USB Cluster Tree based Distributed Reservation Protocol for Mobility Support of Wireless USB device (무선 USB 디바이스의 이동성 지원을 위한 무선USB 클러스터 트리 기반의 분산 예약 프로토콜)

  • Lee, Seong-Ro;Kim, Jeong-Uk;Yang, Jun-Cheol;Bang, Jong-Dae;Kim, Dong-Jin;Jo, Yong-Ok;Kim, Beom-Mu;Yang, Hu-Yeol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.331-333
    • /
    • 2012
  • 본 논문은 UWB 기술 기반 무선 USB(WUSB) 프로토콜에서, 디바이스들의 이동성으로 인해 발생하는 Private Distributed Reservation Protocol (DRP) 예약 충돌 현상을 분석한다. 그리고 Private DRP 예약 충돌 시 발생하는 성능 저하를 감소시키기 위해 Private DRP 충돌 회피 방식을 제안한다. 본 논문에서 제안하는 Private DRP 충돌 회피 프로토콜은 DRD (Dual Role Device)를 이용하여 3홉 범위의 디바이스들의 이동으로 인한 충돌을 방지하는 기법을 제안한다.

  • PDF