• 제목/요약/키워드: Supply water temperature control

검색결과 125건 처리시간 0.032초

A coupled model simulation of the Last Glacial Maximum

  • 김성중
    • 한국제4기학회:학술대회논문집
    • /
    • 한국제4기학회 2004년도 추계학술대회
    • /
    • pp.37-43
    • /
    • 2004
  • The response of the CCCma coupled climate model to the imposition of LGM conditions is investigated. The global mean SAT and SST decrease by about $10^{\circ}C$ and $5.6^{\circ}C$ in the coupled model. Tropical SST decreases by $6.5^{\circ}C$, whereas CLIMAP reconstructions suggest that the tropics cool by only about $1.7^{\circ}C$, although the larger tropical cooling is consistent with the more recent proxy estimates. With the incorporation of a full ocean component, the coupled model gives a realistic spatial SST pattern, capturing features associated with ocean dynamics that are seen in the CLIMAP reconstructions. The larger decrease of the surface temperature in the model is associated with a reduction in global precipitation rate (about 15%). The tropical Pacific warm pool retreats to the west and a mean La $Ni\tilde{n}a$-like response is simulated with less precipitation over the central Pacific and more in the western tropical Pacific. The more arid ocean climate in the LGM results in an increase in SSS almost everywhere. This is particularly the case in the Arctic Ocean where large SSS increase is due to a decrease in river discharge to the Arctic Ocean associated with the accumulation of snow over the ice sheet, but in the North Atlantic by contrast SSS decreases markedly. This remarkable reduction of SSS in the North Atlantic is attributed to an increase in fresh water supply by an increase in discharges from the Mississippi and Amazon rivers and an increase in P-E over the North Atlantic ocean itself. The discharges increase in association with the wetter LGM climate south of the Laurentide ice sheet and in South America. The fresh water capping of the northern North Atlantic results in a marked reduction of deep convection and consequently a marked weakening of the North Atlantic overturning circulation. In the LGM, the maximum overturning stream function associated with the NADW formation decreases by about 60% relative to the control run, while in the Southern Ocean, oceanic convection is stronger in the LGM due to reduced stratification associated with an increase in SSS and a decrease in SST and the overturning stream function associated with the formation of AABW and the outflow increases substantially.

  • PDF

관부 난방시스템과 온수 양액 공급이 온실 에너지 사용량, 딸기 생육 및 생산성에 미치는 영향 분석 (Analysis on the Effect of the Crown Heating System and Warm Nutrient Supply on Energy Usage in Greenhouse, Strawberry Growth and Production)

  • 이태석;김진구;박석호;이재한;문종필
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.271-277
    • /
    • 2021
  • 본 연구에서는 '설향' 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×103 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×103 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.

파일럿 규모의 공정에서 CO2가 함유된 합성가스로부터 합성천연가스(SNG) 생산 (SNG Production from CO2-Rich Syngas in a Pilot Scale SNG Process)

  • 강석환;류재홍;김진호;김효식;유영돈;김준우;고동준;강용
    • Korean Chemical Engineering Research
    • /
    • 제57권3호
    • /
    • pp.420-424
    • /
    • 2019
  • 포항산업과학연구원(RIST, Research Institute of Industrial Science & Technology)-고등기술연구원(IAE, Institute for Advanced Engineering)에서 제안한 합성천연가스(Synthetic Natural Gas, SNG) 제조공정(3개의 단열반응기와 1개의 등온반응기로 구성됨)에서, 합성가스와 함께 스팀을 공급함으로써 메탄화반응과 수성가스전환반응을 동시에 반응시켜 촉매층의 온도와 촉매 비활성화를 제어하였다. SNG 공정개발을 위해 본 연구에서는, 포항산업과학연구원에서 제조한 니켈계 촉매를 사용하여 낮은 $H_2/CO$ 비($CO_2$ 22% 포함) 조건에서의 메탄화반응 특성을 평가하였다. 운전조건(1차 단열반응기의 $H_2O/CO$ 비, 4차 등온반응기의 운전온도 범위 등)은 이전의 연구 결과를 반영하였으며, 동일한 조건을 유지하면서 파일럿 규모의 SNG 공정을 운전하였다. 그 결과, 파일럿 규모의 SNG 공정은 안정적으로 운전되었으며, CO 전환율 100%, $CH_4$ 선택도는 96.9% 그리고 $CH_4$ 생산성은 $660ml/g_{cat}{\cdot}h$의 값을 얻었다.

액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발 (Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

인공수로에서 고농도 탁수가 수질 및 부착 규조류 군집에 미치는 영향 (Effect of Highly Concentrated Turbid Water on the Water Quality and Periphytic Diatom Community in Artificial Channel)

  • 윤성애;유경아;박지형;김백호;황순진
    • 생태와환경
    • /
    • 제44권1호
    • /
    • pp.75-84
    • /
    • 2011
  • 인공하천에서 탁수가 부착조류 군집에 미치는 영향을 평가한 연구는 실내에 인공수로 4개를 설치하고, 대조군 2개와 처리군 2개로 반복실험을 실시하였다. 사용된 기질은 1% agar을 바른 슬라이드 글라스($7.5{\times}2.5\;cm$)이었고, 지점당 40개씩 설치하였다. 조사는 2010년 3월 29일부터 4월 10일까지 총 13일간이었으며, 6일간은 부착조류가 부착할 수 있는 공백기를 주었고, 조사 7일부터 24시간 간격으로 약 50분(50 L)간 고농도의 탁수($2\;g\;L^{-1}$, 300 NTU)를 주입 시켰다. 분석항목은 수질요인(수온, DO, pH, 전기전도도, 탁도, SS, $NO_2$-N, $NO_3$-N, $NH_4$-N, $PO_4$-P, TN, TP)과 생물량(Chl-${\alpha}$, AFDM), 종조성올 분석하였다. 분석 결과, 처리군의 탁수 농도는 162.2~173.2 NTU로 나타났다. 탁수 발생에 따라 감소하는 경향을 보인 수질 항목은 수온, DO 및 TN으로 나타났고, 증가하는 경향을 보인 항목은 SS, $NO_2$-N, $NO_3$-N, $NH_4$-N 및 TP로 나타났다. 부착조류의 생물량(Chl-${\alpha}$, AFDM) 및 밀도는 탁수 주입 후 3 일간 크게 영향을 받지 않았으나 3일 이후부터는 뚜렷한 감소를 보였다. 본 연구의 결과는 단기간의 간헐적인 탁수라 할지라도 그 기간이 일주일 정도 지속된다면 부착 규조류 생물량을 크게 감소시킬 수 있음을 보여주었고, 그를 통한 하천 먹이사슬의 구조적, 기능적 교란의 잠재성을 시사한다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

유해 남조류 제어를 위한 생물유래 살조물질 Naphthoquinone 유도체 (NQ 2-0)의 현장 적용 가능성 (A Field Application Feasibility of Biologically Derived Substances (Naphthoquinone Derivate: NQ 2-0) for the Mitigation of Harmful Cyanobacterial Blooms)

  • 주재형;박종성;최혜정;이헌우;한명수
    • Ecology and Resilient Infrastructure
    • /
    • 제4권3호
    • /
    • pp.130-141
    • /
    • 2017
  • 유해 남조류를 친환경적으로 제어하기 위해 개발된 생물유래 물질인 naphthoquinone (NQ) 유도체의 현장 적용 가능성을 확인하고자 하였다. 기흥 저수지 수변에 30 ton 규모의 mesocosm을 설치하여 현장 조건에서의 살조효과와 비생물학적, 생물학적 요인을 모니터링하였다. NQ 2-0 물질을 처리한 결과, 대조구에서는 대상 조류인 Microcystis sp.의 세포밀도가 지속적으로 증가한 반면, 처리구에서는 실험 초기 $7.9{\times}10^4cells\;mL^{-1}$에서 접종 후 점진적으로 세포수가 감소하여 10일차 $9.7{\times}10^2cells\;mL^{-1}$으로 대조구 대비 99.4% 감소하였다. 실험 종료시인 15일차에는 Microcystis sp. 세포수가 100% 제거되었다. 대상 조류인 Microcystis sp. 종만을 선택적으로 제어하였을 뿐만 아니라, 다른 식물플랑크톤의 성장과 식물플랑크톤 종 다양성 지수도 증진되었다. 또한, 식물플랑크톤을 제외하고 NQ 2-0 물질에 의하여 물리 화학적요인 (수온, 용존 산소, pH, 전기전도도, 영양염)과 생물요인 (박테리아, HNFs, 섬모충, 동물플랑크톤)에 영향을 미치지 않았으며, 대조구와 처리구에서 유사한 경향이 관찰되었다.

곰소만 조간대에서 인의 시공간적 분포 (The Distribution of phosphorus in the Gomso Bay Tidal Flat)

  • 양재삼;김영태
    • 한국해양학회지:바다
    • /
    • 제7권3호
    • /
    • pp.171-180
    • /
    • 2002
  • 곰소만 조간대 퇴적물에서 인의 각 형태에 대한 시공간적인 분포와 관련 환경 인자를 조사하였다. 퇴적물 내 총인(TP), 입자성무기인(PIP), 총유기인(TOP), 용존무기인(DIP)의 곰소만 전체 평균 함량은 각각 548.8mg P kg$^{-1}$, 426.1mg P kg$^{-1}$, 122.6 mg P kg$^{-1}$, 0.217 mg P kg$^{-1}$로써, TP 중 차지하는 순서는 연중 변화 없이 PIP>TOP>DIP이었다. TP는 여름과 겨울간에, 수평적, 수직적으로 일관된 변화는 발견하지 못하였다. 다만, 줄포천 하구에 위치한 조간대 퇴적물에서 높은 TP가 발견되었다. 시기적으로 대부분의 정점에서 8월에 TOP 농도가 높게 나타나 TP중 28.90%를 차지하는 반면, TIP는 71.10%를 차지하고, 11월에는 반대로 TOP가 15.63%로 급격하게 감소하고, TIP가 84.38%를 차지하였다. DIP의 농도 자체는 낮지만, 뚜렷한 계절적인 변화를 보였다. DIP는 모든 정점에서 8월이 11월 보다 3배 높은 농도를 보였다. 이러한 경향은 11월에 비하여 8월 조사기간 동안 퇴적물 내 함유된 유기물의 절대적인 농도에는 차이가 없으나, 높은 수온에 의하여 수층의 일차생산력이 증가하고, 따라서 상층수에서 퇴적물로 공급되는 절대적인 유기물량이 증가함과 동시에 유기물의 분해율 또한 증가한 것으로 생각된다. 따라서 공극수 내 DIP의 농도가 증가되었을 것이다. 여름철 퇴적물의 표층 하에서 혐기성 조건이 조성되어 퇴적 입자에 흡착되었던 PIP의 일부가 낮은 pH, Eh환경에서 용존 상태로 전환된 부분도 있었을 것이다. 따라서 이러한 변화에 대한 가장 중요한 요인으로 곰소만 조간대 퇴적물 내 인의 분포는 일차적으로 줄포천과 같이 생활하수가 집중적으로 공급되는 곳에서 높은 TP 농도를 보였고, 시기적으로 PIP와 DIP는 강한 계절적인 차이를 나타내었으며 , 이는 주로 하절기 높은 수온과 유기물 함량이 여타 다른 환경을 변화시킴으로써 나타나는 것으로 생각된다.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축 (Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components)

  • 배영덕;김석권;이동원;신희윤;홍봉근
    • 한국진공학회지
    • /
    • 제18권4호
    • /
    • pp.318-330
    • /
    • 2009
  • 본 한국원자력연구원에서는 국제열핵융합실험로(ITER)의 일차벽을 개발하기 위해 그라파이트 히터를 이용한 고열부하 시험시설 KoHLT-1(Korea Heat Load Test facility-1)을 구축하였으며, 현재 정상적으로 가동되고 있다. KoHLT-1의 주목적은 Be-CuCrZr-SS의 이종 금속이 HIP 방법에 의해 접합된 ITER 일차벽 mockup의 접합 건전성을 확인하는데 있다. KoHLT-1은 판형 그라파이트 히터, 냉각 jacket이 부착된 상자형 시험용기, 직류 전원, 냉각계통, He 기체 공급계통과 각종 진단계통으로 구성되어 있으며, 이 모든 시설은 Be 처리가 가능한 특수 정화계통이 설치된 실험실에 설치되었다. 그라파이트 히터는 두개의 시험 대상물 사이에 설치되며, 시험대상물과의 거리는 $2{\sim}3\;mm$이다. 시험 대상물의 크기와 요구되는 열유속에 따라 여러 가지의 그라파이트 히터를 설계, 제작하였으며, 전기 저항은 고온 운전 중에 $0.2{\sim}0.5{\Omega}$이 되도록 하였다. 히터는 100V/400 A의 직류전원에 연결되어 있으며, PC와 multi function module로 구성된 전류 조정계통에 의해 미리 프로그램되어 있는 패턴으로 전류를 자동 조절하게 된다. 두 시험대상물에 인가되는 열유속은 calorimetry법에 의해 냉각수의 입, 출구 온도와 유량을 측정하여 얻게 된다. 여러 가지 형태의 ITER 일차벽 Be mockups에 대해 고열부하 시험을 수행하였으며, 시험을 통하여 KoHLT-1 고열부하 시험 시설의 성능이 확인되었고, 24시간 이상의 연속 운전에 있어서도 그 신뢰성이 입증되었다.