• Title/Summary/Keyword: Supply condition

Search Result 1,498, Processing Time 0.034 seconds

Survey on Housing Facilities and Management of Broiler Welfare Certified Farms (국내 동물복지 인증 육계농가의 사육시설 및 사육현황)

  • Cheon, Si Nae;Yoo, Geum Zoo;Jung, Ji Yeon;Kim, Chan Ho;Kim, Dong-Hoon;Jeon, Jung Hwan
    • Korean Journal of Organic Agriculture
    • /
    • v.29 no.2
    • /
    • pp.209-221
    • /
    • 2021
  • The purpose of this study is to obtain basic data on housing facilities and management of broiler welfare certified farms in Korea. We investigated breeds, flock sizes, stocking density, perches, litter, plumage condition, and other diseases. In addition, we measured temperature, relative humidity, light intensity, ammonia, and carbon dioxide concentration in the barn. As result, criteria were met in all cases that we investigated. However, farmers commonly demanded relaxation of perch and litter. Perch usage of broiler was impractical due to low usage of it. Also, litter was increased, resulting in farmers' economic burden by the imbalance between supply and demand. This situation makes farmers reuse the litter. Unfortunately, there are no clear certification standards. During re-inspection, the animal welfare certification of farms was canceled due to the reuse of litter. It is difficult to modify the standard of perch due to the strong declarative meaning of animal welfare rather than the necessity of perch usage, however, the reuse of litter should be improved. It is important to think and solve any problems faced by all farms. Especially, animal welfare standards need to be improved in more clarity and rationality.

High Temperature Corrosion Effect of Superheater Materials by Alkali Chlorides (염화알칼리에 의한 과열기 소재의 고온부식 영향)

  • Kim, Beomjong;Jeong, Soohwa;Kim, Hyesoo;Ryu, Changkook;Lee, Uendo
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2018
  • In order to cope with environmental problems and climate change caused by fossil fuels, renewable energy supply is increasing year by year. Currently, waste energy accounts for 60% of renewable energy production. However, waste has a lower calorific value than fossil fuels and contains various harmful substances, which causes serious problems when applied to power generation boilers. In particular, the chlorine in the waste fuel increases slagging and fouling of boiler heat exchangers, leading to a reduction in thermal efficiency and the main cause of high temperature corrosion, lowering facility operation rate and increasing operating cost. In this study, the high temperature corrosion experiments of superheater materials (ASME SA213/ASTM A213 T2, T12 and T22 alloy steel) by alkali chlorides were conducted, and their corrosion characteristics were analyzed by the weight loss method and SEM-EDS. Experiments show that the higher the temperature and chloride content, the more corrosion occurs, and KCl further corrodes the materials compared to NaCl under the same condition. In addition, the higher the chromium content of the material, the better the corrosion resistance to the alkali chlorides.

Development of Fermentation Process of Ginseng Leaf Extraction Probiotic Strain and Characterization of Product Quality (프로바이오틱 균주에 의한 인삼 잎 추출물 발효공정 확립 및 생성물의 품질 특성분석)

  • Hur, Sang-Sun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1213-1223
    • /
    • 2018
  • This study was carried out to investigate extraction efficiency by microwave for extraction of pesticide residues and the bioconversion of ginsenosides of ginseng leaf by using various lactic acid bacteria in order to promote the utilization of ginseng leaf. The hexane extraction by microwave of tolclofos-methyl and azoxystrobin in ginseng leaf was efficient. The optimal condition for extraction of tolclofos-methyl and azoxystrobin in ginseng leaf by microwave was 50 to 95 watts of power supply, 3 minutes of extraction.The gisenosides Rg1 and Rb1 contents have decreased, while the Rh1, Rg3, Rk1 and Rh2 have increased due to fermentation. The ginsenosides Rg3 of the fermented ginseng leaf has increased and the contents were $70.62{\sim}77.61{\mu}g/g$(control $2.77{\mu}g/g$). The total phenolic acid content and electron donating ability of the ginseng leaf have totally decreased after 7 days of fermentation. The total phenolic acid contents of the fermented ginseng leaf with various lactic acid bacteria did not show any tendency as different strains.

An Empirical Analysis on the Working Conditions of Construction Technician (건설 기능인력 근무여건에 대한 실증 분석)

  • Yang, Jinkook;Lee, Taeshin;Lee, Jongmin;Lee, Sangbeom
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • The construction phase of the construction project needs a large scale of manpower, materials and equipment. Among them, manpower is a core part for project construction. These manpower are divided into two groups. The first is the management group that manages the construction, and the second is the site technician manpower for construction work. Recently, construction company has suffering due to the insufficient supply of technician labor. Accordingly, this study will perform an empirical analysis about the construction technician. To do this, we surveyed related research trends and conducted surveys on the satisfaction of the construction technician. The result, satisfaction with pay and insurance was relatively low compared to other items. Therefore, this study were conducted in-depth interviews with technician managers in order to analyze the cause. In addition, case analysis was conducted to analyze actual working conditions. As a result, it was analyzed that the wage level and insurance system of construction technician were considerably stable compared to the manufacturing industry. The result of this study is expected to contribute to the activation of excellent technician cultivation through the change of recognition about construction technician.

Comparison of Mcrobial and Physicochemical Properties between Pogi Kimchi and Mat Kimchi (포기김치와 맛김치의 미생물학적 및 이화학적 품질 특성 비교)

  • Moon, Eun Woo;Kim, Su-Yeon;Dang, Yun-Mi;Park, Boyeon;Park, Eun Jin;Song, Hye Yeon;Yang, Jisu;Yoon, So Ra;Seo, Hye-Young;Ha, Ji-Hyoung
    • Journal of the Korean Society of Food Culture
    • /
    • v.34 no.2
    • /
    • pp.217-223
    • /
    • 2019
  • This study aimed to evaluate the characteristic differential between whole cabbage kimchi (pogi kimchi) and sliced cabbage kimchi (mat kimchi) during kimchi fermentation at $6^{\circ}C$. The difference of microbial and physicochemical properties was investigated until 6 weeks. For the changes in the microbial flora, both kimchi samples exhibited a continuous increase in total aerobic bacteria and lactic acid bacteria (LAB) population size up to 2 weeks followed by a stationary phase until 5 weeks. Interestingly, the number of LAB of mat kimchi was overall higher than that of pogi kimchi during kimchi fermentation. We speculate that mat kimchi has in a more advantageous growth condition than pogi kimchi for microbial growth because small kimchi cabbage size appropriately derives nutritional supply in order to increase the LAB growth. During lactic fermentation at $6^{\circ}C$, physicochemical changes in the pH, salinity, and titratable acidity was observed to be no significant differences between two types of kimchi. Furthermore the contents of organic acids such as oxalic acid, citric acid, malic acid, lactic acid, fumaric acid, and acetic acid was not significantly different (p>0.05) between both kimchi samples as well as the contents of total free amino acid.

Economical Analysis of the PV-linked Residential ESS using HOMER in Korea (HOMER를 이용한 PV 연계 가정용 ESS의 경제성 분석)

  • Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.36-42
    • /
    • 2019
  • Europe and North America are paying attention to residential ESS(Energy Storage System) that can manage energy efficiently. The ESS is a system that stores and manages the electric power by charging and discharging the battery. The ESS is generally used in conjunction with photovoltaic systems. The ESS supplies the load of the power generation time and stores the remaining PV power to supply the load at the non-power generation time. However, due to the high price of residential ESS, low electric rates and increasing block rates, there is no market of residential ESS in Korea. This paper reviews the price condition and the capacity for applying PV and residential ESS to household of apartments using HOMER in Korea.

Study on Determination of Design Factor of Bioreactor for Sulfate Reduction in Mine Drainage (광산배수 내 황산염 저감을 위한 생물반응기의 설계인자 도출 연구)

  • Kim, Kang-Ho;Kang, Chan-Ung;Kim, Sun-Joon;Kim, Tae-Heok;Ji, Won-Hyun;Jang, Hang-Seok;Park, Hyun-Sung
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.527-537
    • /
    • 2018
  • Column tests of a sulfate reducing bacteria (SRB) bioreactor were conducted to determine the design factors for sulfate-rich mine drainage. Various substrates were applied to the bioreactor, including cow manure and its mixture with a mushroom compost, with rice straw and limestone as subsidiary materials. This procedure provided a removal efficiency of up to 82% of the total sulfur with the mixture of cow manure (70%), mushroom compost (10%) and rice straw (20%), and higher efficiencies were observed after 2 days of retention time. In the downflow condition of the flow direction, oxygen supply and re-oxidation of the sulfates occurred, causing a decrease in sulfate removal efficiency. The addition of an inorganic sludge containing heavy metals, which was intended for production of metal-sulfides in the bioreactor, had a negative effect on the long-term operation owing to arsenic release and toxicity to the SRB. The results thus show that a bioreactor using a mixed substrate with cow manure and operating in the downflow direction could reduce sulfates and total dissolved sulfur content; this process confirms the applicability of the SRB bioreactor to sulfate-rich saline drainage.

Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network (상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발)

  • Jeong, Bobae;Kim, Kibum;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

Real-world Treatment Pattern and Outcomes of Hypercalcemia among Solid Tumor Patients (성인 고형암 환자의 고칼슘혈증 치료현황과 치료효과 분석)

  • Shin, Da Eun;Park, Seol Hee;Kim, Sung Hwan;Suh, Sung Yun;Jo, Yun Hee;Cho, Yoon Sook;Im, Seock-Ah;Lee, Ju-Yeun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.29 no.3
    • /
    • pp.166-172
    • /
    • 2019
  • Background: Hypercalcemia is an important metabolic emergency condition in cancer patients. Bisphosphonate is the treatment of choice for hypercalcemia, whereas calcitonin and hydration with furosemide are recommended for acute supportive therapy. However, data regarding real-world treatment patterns and outcomes of pharmacological treatments are limited. Therefore, we aimed to investigate the treatment patterns and clinical outcomes of hypercalcemia treatment in solid tumor patients. Methods: Electronic medical records of 123 adults with solid cancers and albumin-corrected calcium levels >10.5 mg/dL or ionized calcium levels >1.35 mmol/L were reviewed. We retrospectively analyzed the pharmacological treatment and recovery rate according to the severity of hypercalcemia. Results: A total of 177 cases were identified, of which 49 were not treated and 30 were treated with hydration only. In moderate-to-severe cases, 86.5% received pharmacological treatment. Thirty-four cases (19.2%) were treated with bisphosphonate alone and 58 cases (32.8%) were treated with bisphosphonate and calcitonin. In mild hypercalcemia cases, the recovery rate was higher for those receiving hydration only or pharmacological treatment (79.7%) than for those receiving no treatment (61.4%, p = 0.041). Most moderate-to-severe cases were treated with medication and of those treated, 56.3% recovered. The recovery rate was lower in those treated with bisphosphonate alone (38.2%) than in those who underwent calcitonin combination treatment (73.7%, p = 0.001). Conclusions: Bisphosphonate combined with calcitonin was found to be more effective than bisphosphonate alone for the treatment of moderate-to-severe hypercalcemia. Considering the current shortage of calcitonin, further efforts are required to ensure its stable supply.

Study for Flow Phenomenon in the Circulation Water Pump Chamber using the Flow-3D Model (Flow-3D 모형을 이용한 순환수취수펌프장 내 흐름현상 연구)

  • Ha, Sung-Won;Kim, Tae-Won;Choi, Joo-Hwan;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.580-589
    • /
    • 2019
  • Indonesia has a very short supply of electricity. As a solution to this problem, plans for construction of thermal power plants are increasing. Thermal power plant require the cooling water system to cool the overheated engine and equipment that accompany power generation, and the circulation water pump chamber among the cooling water system are generally designed according to the ANSI (1998) standard. In this study, the design criterion $20^{\circ}$ for the spreading angle of the ANSI (1998) of the layout of the circulating water pump chamber can not be satisfied on the K-coal thermal power plant site condition in Indonesia. Therefore, 3-D numerical model experiment was carried out to obtain a hydraulically stable flow and stable structure. The Flow-3D model was used as numerical model. In order to examine the applicability of the Flow-3D model, the flow study results around the rectangular structure of Rodi (1997) and the numerical analysis results were compared around the rectangular structures. The longitudinal velocity distribution derived from numerical analysis show good agreement. In order to satisfy the design velocity in the circulating water pump chamber, a rectangular baffle favoring velocity reduction was applied. When the approach velocity into the circulating water pump chamber was occurred 1.5 m/s ~ 2.5 m/s, the angle of the separation flow on the baffle was occurred about $15^{\circ}{\sim}20^{\circ}$. By placing the baffle below the separation flow angle downstream, the design velocity of less than 0.5 m/s was satisfied at inlet bay.